- Automation & ControlView all 2,718 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: ifm
ifm SM6000 Magnetic-Inductive Flow Meter, G 1/2, 0.1-25 l/min
Description
ifm SM6000 Magnetic-Inductive Flow Meter, G 1/2, 0.1-25 l/min
The ifm SM6000 is a magnetic-inductive flow meter for conductive liquids with a measuring range of 0.1 to 25 l/min (0.005 to 1.5 m³/h) and a resolution of 0.02 l/min. It has a G 1/2 external thread (DN15, flat seal), is rated for 16 bar and handles medium temperatures from -10 to 70 degrees Celsius. A 4-digit LED display shows flow, consumption or temperature.
Outputs are switching, analogue 4 to 20 mA, pulse and IO-Link. Accuracy is plus or minus (0.8 percent of measured value plus 0.5 percent of final value) with repeatability of 0.2 percent, and protection is IP67. Seven Star LLC supplies the ifm SM6000 in Oman and the GCC as an independent supplier in Muscat.
SM6000 technical specifications
The table lists the values published by the manufacturer for the SM6000. Where a parameter has several operating modes, the headline value is shown; the full parameter list is in the manufacturer documentation.
| Parameter | Specification |
|---|---|
| Manufacturer / part number | ifm electronic / SM6000 |
| Measuring range | 0.1 to 25 l/min / 0.005 to 1.5 m³/h |
| Resolution | 0.02 l/min: 0.002 m³/h |
| Process connection | threaded connection G 1/2 external thread DN15 flat seal |
| Dimensions [mm] | Ø 54 / L = 110 |
| Media | conductive liquids; water; hydrous media |
| Medium temperature [°C] | -10 to 70 |
| Pressure rating | 16 bar / 1.6 MPa |
| Operating voltage [V] | 18 to 30 DC (to SELV/PELV) |
| Current consumption [mA] | 95 (24 V) |
| Output signal | switching signal; analogue signal; pulse signal; IO-Link (configurable) |
| Electrical design | PNP/NPN |
| Output function | normally open / normally closed (parameterisable) |
| Permanent current rating of switching output DC [mA] | 200 |
| Analogue current output [mA] | 4 to 20; (scalable) |
| Max. load [Ω] | 500 |
| Accuracy (in the measuring range) | ± (0.8 % MW + 0.5 % MEW) |
| Accuracy [K] | ± 2.5 (Q > 1 l/min) |
| Repeatability | ± 0.2% MEW |
| Response time [s] | 0.15 (dAP = 0, T19) |
| Communication interface | IO-Link |
| Ambient temperature [°C] | -10 to 60 |
| Protection | IP 67 |
| Weight [g] | 544 |
| Materials | stainless steel (316L/1.4404); PBT-GF20; PC; FKM; TPE |
| Materials (wetted parts) | stainless steel (316L/1.4404); PEEK; FKM |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |
| MTTF [years] | 162 |
How the SM6000 works
The SM6000 is a magnetic-inductive flow meter: a magnetic field is applied across the pipe, and a conductive liquid moving through the field induces a voltage proportional to its velocity. Because nothing protrudes into the flow, there are no moving parts to wear and the pressure loss is very small. A temperature sensor in the same unit adds medium temperature as a second measured value, shown on a four-digit LED display and available on the outputs. The liquid must be conductive; the conductivity and viscosity limits stated in the table must be respected.
Where the SM6000 fits and related parts
The SM6000 is the small-flow magnetic type. The SM6004 and SM8000 in our range cover other sizes, and the SV4200 uses a vortex principle for water and coolants.
Selection and ordering checklist for the SM6000
Work through the points below before you confirm the order, so that the SM6000 you receive is the one your machine or plant needs.
- Check that the liquid is conductive
- Check the flow range of 0.1 to 25 l/min
- Confirm G 1/2 external thread and flat seal
- Choose the output (switching, analogue, pulse, IO-Link)
- Confirm the 18 to 30 V DC SELV/PELV supply
The manufacturer lists this article under the type designation Magnetic-inductive flow meter, SMR12GGXFRKG/US-100. The article number SM6000 is the reference to quote when ordering, and the type designation is useful for technicians who compare the label on an installed unit.
Installation, commissioning and maintenance
Install the meter with the inlet and outlet pipe lengths shown in the table so that the profile is stable, and keep the pipe full at all times; air pockets cause unstable readings. Flat seals are used on the thread, so make sure the sealing surfaces are clean and the adapters fit the pipe. In cooling circuits and process water loops place the meter where bubbles will not collect at the top. Commissioning involves setting the display unit, the analogue range and the damping value, and then comparing a reading against a reference flow if the application is critical. Keep the M12 connector dry and tight, and flush the line if scale or magnetic debris could build up.
Typical applications in Oman and the GCC
Dosing and batching of water-based liquids, metering of cooling water, and consumption monitoring of process water. In Oman and the GCC it suits desalination dosing lines and utility metering.
Flow meters in the region often sit in cooling and utility circuits that run year-round at high ambient temperature. Scale, bubbles and dirt are the main sources of error, so strainers upstream and a full pipe at the measuring point matter more than any setting in the menu.
SM6000 compared with related ifm types
The table places the SM6000 next to neighbouring types in the same application group, so you can see whether a sibling would suit the job better.
| Part number | Key characteristics | Note |
|---|---|---|
| SI5000 | Calorimetric, M18 x 1.5, 30 bar, liquids and gases | Related type |
| SV4200 | Vortex, G 1/2, 1-20 l/min, to 90 C, IO-Link | Related type |
| SM6000 | Mag-inductive, G 1/2 ext., 0.1-25 l/min, 16 bar | This page |
| SM6004 | Magnetic-inductive flow meter | Related type |
| SM8000 | Magnetic-inductive flow meter | Related type |
| SA5000 | Flow sensor | Related type |
Information to send with an RFQ for the SM6000
To prepare an accurate offer for the SM6000, please include the following with your enquiry:
- Pipe size and the type of adapter needed
- Expected flow range and the minimum flow you must detect
- Medium, conductivity and temperature
- Outputs required: analogue, switching, pulse or IO-Link
- Quantity and delivery location
Documents and quotation
The official ifm data sheet for the SM6000 (document SM6000-03, English, issued 13 April 2023) is attached on this page as a PDF. It sets out the electrical data, the output function, the operating conditions, the approvals and the dimension drawing for this article. Check these values and the wiring diagram against your application before ordering, then send us the quantity and the delivery location for a quotation.
Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC and is not affiliated with the manufacturer; the name ifm is used only to identify the product. Prices are not shown on the page, so send the part number, the quantity and the delivery location to receive a quotation.
Other Models in the Ifm61 Flow Range
Seven Star LLC supplies models from the Ifm61 Flow range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ifm SI5000 Flow Monitor, Calorimetric, Liquids and Gases, 30 bar | Automation Accessories | View details |
| ifm SV4200 Vortex Flow Meter with Display, G 1/2, 1-20 l/min | Automation Accessories | View details |
| ifm SM6000 Magnetic-Inductive Flow Meter, G 1/2, 0.1-25 l/min | Automation Accessories | You are viewing this model |
Datasheets & Documents
- Datasheet ifm SM6000 Data Sheet (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ifm is a German family-owned maker of sensors and automation products, founded in Essen in October 1969 by Robert Buck and Gerd Marhofer. Its first products were inductive proximity sensors sold under the efector name. ifm is still headquartered in Essen, and the founders' sons, Martin Buck and Michael Marhofer, have led it since 2001.
Seven Star LLC lists ifm position, distance and pressure sensors and supplies them by exact article number to plants and machine builders in Oman and the wider Gulf region.
ifm company profile
| Founded | 1969, Essen, Germany |
|---|---|
| Founders | Robert Buck and Gerd Marhofer |
| Headquarters | Essen, Germany |
| Ownership | Family-owned |
| Product families | Inductive and capacitive proximity sensors, PN pressure sensors, O1D laser distance sensors, flow and level sensors, IO-Link masters |
Milestones
- 1969: ifm is founded in Essen.
- 2001: The founders' sons take over management.
ifm sensors listed on this page
ifm identifies every device with a short article number, and that number is what we order against. Three are listed here:
- O1D100: laser distance sensor for position and distance measurement
- PN7093: pressure sensor with local display
- NG5021: inductive proximity sensor with NAMUR output
Other ifm inductive sensors, pressure sensors and connection cables can be quoted on request when you send the article number.
ifm products we list
Ordering ifm sensors: what we need
Send the six-character article number printed on the housing (two letters and four digits, or similar). If the label is worn, a photo plus the thread size, sensing range, output type and connector style is enough for us to check the part against ifm documentation. For NAMUR sensors, tell us which isolating amplifier is in the loop. Buyers in the GCC who need a successor for a discontinued article can send the old number and we will check the replacement the manufacturer names.
Facts checked against ifm's own 50-year chronicle (ifm.com), October 2026.
Browse ifm products by category: Sensors & Transmitters, Pressure Instrumentation.
FAQ
Questions about the ifm SM6000 Magnetic-Inductive Flow Meter, G 1/2,
Answers from our engineering team on installation, compatibility and integration.
01Which liquids can the ifm SM6000 measure?
Conductive liquids, including water and hydrous media.
02What range does the SM6000 measure?
0.1 to 25 l/min. This is the value published by the manufacturer for the SM6000; confirm details before ordering.
03What outputs does the SM6000 have?
Switching, analogue 4 to 20 mA, pulse and IO-Link.
04What is the pressure rating of the SM6000?
16 bar (1.6 MPa). This is the value published by the manufacturer for the SM6000; confirm details before ordering.
05What is the response time of the SM6000?
0.15 s as listed by the manufacturer. This is the value published by the manufacturer for the SM6000; confirm details before ordering.


















Reviews
There are no reviews yet.