Brand:

ifm AL1100 IO-Link Master, PROFINET, 4 ports, IP67

Description

ifm AL1100 IO-Link Master, PROFINET, 4 ports, IP67

The ifm AL1100 is an IO-Link master with an integrated PROFINET interface, built for field mounting in IP65, IP66 and IP67. It brings machine data, process parameters and diagnostic data from four class A IO-Link ports to the controller over 100Base-TX Ethernet, and it supports Conformance Class C (IRT switch) and Netload class III. Eight channels can be configured as digital inputs or outputs.

Ports and sockets are standard M12: two D-coded for Ethernet, four A-coded for sensors and one A-coded for power. Seven Star LLC supplies the AL1100 in Oman and the GCC as an independent supplier in Muscat.

AL1100 technical specifications

The table lists the values published by the manufacturer for the AL1100. Where a parameter has several operating modes, the headline value is shown; the full parameter list is in the manufacturer documentation.

Parameter Specification
Manufacturer / part number ifm electronic / AL1100
Dimensions [mm] 152 x 59.3 x 38.4
Operating voltage [V] 20 to 30 DC (US ; to SELV/PELV)
Current consumption [mA] 300 to 3900 (US)
Communication interface Ethernet; IO-Link
Protocol PROFINET
Ambient temperature [°C] -25 to 60
Protection IP 65; IP 66; IP 67
Weight [g] 297.9
Materials housing: PA orange; socket: brass nickel-plated
Connector 2 x M12; coding: D; Contacts: 4; Sealing: FKM
MTTF [years] 96

How the AL1100 works

The AL1100 is an IO-Link master in an IP67 housing for installation in the field. It connects up to four IO-Link devices through class A ports, collects their process data and diagnostics, and exchanges them with a higher-level system over its Ethernet interface. Each port can also work as a standard digital input or output. A star topology with simple M12 cables replaces long runs of individual sensor cables back to the cabinet.

Where the AL1100 fits and related parts

The AL1100 is a direct PROFINET device, so a PLC can address the IO-Link sensors without extra gateways. The AL1350 offers the same hardware with an IoT interface. For sensor choices, devices such as the PN70 pressure sensors, the SM8000 flow meter and the TA2105 temperature transmitter are all IO-Link capable.

Selection and ordering checklist for the AL1100

Work through the points below before you confirm the order, so that the AL1100 you receive is the one your machine or plant needs.

  • Check that the controller supports PROFINET
  • Count the IO-Link devices (four ports)
  • Plan 20 to 30 V DC supply for the master and attached devices
  • Plan the GSD file and device naming
  • Plan the cable lengths for sensors

The manufacturer lists this article under the type designation IO-Link master with PROFINET interface, IO-Link Master SL PN 4P IP67. The article number AL1100 is the reference to quote when ordering, and the type designation is useful for technicians who compare the label on an installed unit.

Installation, commissioning and maintenance

Mount the master on a backplane near the sensors, connect the 24 V supply via the power connector and the Ethernet cable via the D-coded sockets, and plug the sensors into the A-coded ports. For commissioning, assign the IP settings, scan the ports and load the device descriptions. Keep unused ports closed with blanking caps to retain the protection rating. Maintenance consists of checking the connectors, supply voltage and port status.

Assign the device name and IP address from the engineering tool, import the GSD file, and map the IO-Link ports. Test every port with the connected device and a diagnostic read. Use blanking caps for unused sockets, and keep the backplane mounting rigid. With PROFINET, a replacement master can take over the device name from the controller or the engineering tool, and the IO-Link sensors behind it keep their parameters when the master stores them, so a swap in the field takes minutes rather than hours. Keep a record of which sensor sits on which port, and note the supply wiring, because the total current of the connected devices must stay within the limit of 3.6 A.

Typical applications in Oman and the GCC

Machine builders and plant integrators use it to connect distributed sensors in fabrication, packaging and process skids. In Oman and the GCC, it serves packages built around PROFINET-based PLCs.

Field-mounted masters see heat, dust and washdown. Keep unused ports capped, support the cables so connectors are not loaded, and document the port assignment of each sensor for faster troubleshooting.

AL1100 compared with related ifm types

The table places the AL1100 next to neighbouring types in the same application group, so you can see whether a sibling would suit the job better.

Part number Key characteristics Note
AL1350 IoT: MQTT JSON, HTTPS, 4 ports Related type
AL1100 PROFINET CC-C, 4 ports This page

Information to send with an RFQ for the AL1100

To prepare an accurate offer for the AL1100, please include the following with your enquiry:

  • Network type and protocol required
  • Number and type of IO-Link devices
  • Supply voltage arrangement
  • Cable types and lengths
  • Quantity and delivery location

Storage, handling and spares for the ifm AL1100

Keep the ifm AL1100 in its original packaging until installation, and store it indoors in a dry place without condensation. Protect connectors and cable ends from dust and moisture. In hot GCC warehouses, check that the storage temperature stays inside the range given in the manufacturer datasheet before the unit is installed.

  • Check the article number and connection type against the drawing before mounting.
  • Use the mounting accessories and connection cables recommended for the device, and route cables away from power wiring.
  • Keep at least one spare unit of each type used on critical machines, so that a failed device can be swapped quickly.
  • Record the device type, firmware version where relevant, and parameter settings, so that a replacement can be set up the same way.

When you order the ifm AL1100, include the matching cables, connectors or mounting parts in the same RFQ. This avoids delays at commissioning when a small accessory is missing.

Documents and quotation

No datasheet is attached to this page. Send us the part number AL1100 and we will confirm which documents are available, such as the datasheet and operating instructions, and for IO-Link devices the device description file.

Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC and is not affiliated with the manufacturer; the name ifm is used only to identify the product. Prices are not shown on the page, so send the part number, the quantity and the delivery location to receive a quotation.

Other Models in the Ifm Iolm Range

Seven Star LLC supplies models from the Ifm Iolm range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ifm AL1350 IO-Link Master, IoT MQTT JSON, 4 ports, IP67Industrial CommunicationsView details
ifm AL1100 IO-Link Master, PROFINET, 4 ports, IP67Industrial CommunicationsYou are viewing this model
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ifm is a German family-owned maker of sensors and automation products, founded in Essen in October 1969 by Robert Buck and Gerd Marhofer. Its first products were inductive proximity sensors sold under the efector name. ifm is still headquartered in Essen, and the founders' sons, Martin Buck and Michael Marhofer, have led it since 2001.

Seven Star LLC lists ifm position, distance and pressure sensors and supplies them by exact article number to plants and machine builders in Oman and the wider Gulf region.

ifm company profile

Founded 1969, Essen, Germany
Founders Robert Buck and Gerd Marhofer
Headquarters Essen, Germany
Ownership Family-owned
Product families Inductive and capacitive proximity sensors, PN pressure sensors, O1D laser distance sensors, flow and level sensors, IO-Link masters

Milestones

  • 1969: ifm is founded in Essen.
  • 2001: The founders' sons take over management.

ifm sensors listed on this page

ifm identifies every device with a short article number, and that number is what we order against. Three are listed here:

  • O1D100: laser distance sensor for position and distance measurement
  • PN7093: pressure sensor with local display
  • NG5021: inductive proximity sensor with NAMUR output

Other ifm inductive sensors, pressure sensors and connection cables can be quoted on request when you send the article number.

ifm products we list

Family Examples
Inductive Proximity Sensors NG5021 Inductive NAMUR Proximity Sensor
Laser Distance, LiDAR & Radar Sensors O1D100 Laser Distance Sensor
Pressure Instrumentation PN7093 Pressure Sensor with Display

Ordering ifm sensors: what we need

Send the six-character article number printed on the housing (two letters and four digits, or similar). If the label is worn, a photo plus the thread size, sensing range, output type and connector style is enough for us to check the part against ifm documentation. For NAMUR sensors, tell us which isolating amplifier is in the loop. Buyers in the GCC who need a successor for a discontinued article can send the old number and we will check the replacement the manufacturer names.

Facts checked against ifm's own 50-year chronicle (ifm.com), October 2026.

FAQ

Questions about the ifm AL1100 IO-Link Master, PROFINET, 4 ports, IP67

Answers from our engineering team on installation, compatibility and integration.

01What fieldbus interface does the ifm AL1100 have?
PROFINET with Conformance Class C (IRT switch) and Netload class III.
02How many ports does the AL1100 have?
Four class A IO-Link ports with eight configurable inputs/outputs.
03What speed does the AL1100 Ethernet run at?
100 Mbit/s (100Base-TX). This is the value published by the manufacturer for the AL1100; confirm details before ordering.
04What is the protection of the AL1100?
IP65, IP66 and IP67. This is the value published by the manufacturer for the AL1100; confirm details before ordering.
05What is the supply of the AL1100?
20 to 30 V DC. This is the value published by the manufacturer for the AL1100; confirm details before ordering.