Brand: Hydac
Hydac MFDBN160AULF10A1.1/16-3B3.4 Duplex Spin-On Filter
Description
A dual-can spin-on filter that is quick to service
The Hydac MFDBN160AULF10A1.1/16-3B3.4 (HYDAC part number 2064368) is an in-line duplex spin-on filter from the MF, MFD and MFDS family. Two filter heads and elements are mounted end to end, so you get the quick, tool-free element changes of spin-on cans with the flow capacity of two cans. This code is rated 30 gpm (114 L/min) at a working pressure of 8 bar (120 psi) with a 10 micron Betamicron low-collapse element.
The head is aluminum and the can is steel, with a combined connection for 1 1/2 inch NPT and 2 inch SAE Code 61 flange, a 50 psid bypass and a plugged indicator port.
Technical specifications
| Parameter | Specification |
|---|---|
| HYDAC part number | 2064368 |
| Model code | MFDBN160AULF10A1.1/16-3B3.4 |
| Filter type | In-line duplex spin-on, end to end |
| Size | 160 |
| Flow capacity | 30 gpm (114 L/min) as listed in the catalogue |
| Max. allowable working pressure | 8 bar (120 psi) |
| Filter rating | 10 micron, Betamicron low-collapse (BN), microglass |
| Port connection | 1 1/2 in NPT and 2 in SAE Code 61 flange combination |
| Head / can material | Aluminum / steel |
| Element connection | UN thread |
| Bypass valve | 50 psid (3.4 bar), code B3.4 |
| Element collapse rating | 80 psid (5.5 bar) |
| Clogging indicator | A: no indicator, port plugged |
| Fluid temperature | -10 to +100 °C (14 to 212 °F) |
| Mounting | 2 mounting holes |
| Fluids | Petroleum oils and synthetic fluids compatible with NBR |
| Weight | 8.8 lb |
Order code explained
MFD BN 160 A U LF 10 A 1 . 1 / 16-3 B3.4: MFD is the dual-head end-to-end filter, BN the Betamicron low-collapse media, 160 the size, A the 120 psi pressure rating, U the UN element thread, LF the 1 1/2 inch threaded and 2 inch flange combination, 10 the micron rating, A no indicator, the first 1 the type number, the second 1 the modification number, /16-3 the combined NPT and SAE Code 61 flange ports and B3.4 the 50 psid bypass, standard on BN elements. In the datasheet the 16-3 port code is listed for the side-by-side MFDS filters, so confirm the port arrangement against the drawing.
Using it
The datasheet says MF filters suit hydrocarbon-based fluids only and are not suitable for high-water-based fluids or phosphate esters. Typical applications listed include agricultural, automotive, construction, gearbox, industrial, pulp and paper and steel industry equipment. Note that the maximum allowable working pressure drops to 60 psi when certain static VMF indicators (B, BM, E, ES, GC, LE or LZ) are fitted, so check the indicator choice. Spare elements are the size 160 type, and two are needed per filter.
Spin-on cans are quick to change but should be replaced as a set when the indicator trips. Mount the filter with the cans pointing down and leave room below for removal, and keep a spare pair of elements, since the datasheet lists size 160 elements as the replacement part.
Where the system cannot be stopped, consider a bypass or a changeover arrangement, because a spin-on element has to be replaced with the line depressurised. The 50 psid bypass opens when the elements load up and the indicator port allows a gauge or switch to be fitted later, so plan that port location when you install the filter.
Related Hydac products: Hydac RFD330DALXXA1.1/16V Duplex Return Filter, 330 L/min, Hydac HF4R-BN-18VF10E1.2/3B2.7T In-Tank Return Filter, Hydac NFH ON 1300EP10A1.1/16 Return Filter, 1300 L/min, Hydac LPFH ON 325 E F 10 A 1.0/12 Inline Filter, 500 psi, Hydac MF and MFD Spin-On Filter, up to 300 l/min and 8 bar and Hydac DFP160QCXXA1.0 Manifold Mount Pressure Filter, 160 L/min.
Documents and quotation
The MF/MFD/MFDS datasheet is attached. Please give the flow, fluid and indicator requirements. See also our hydraulic filter housings range.
How the MFDBN160AULF10A1.1/16-3B3.4 works
Oil enters the aluminum head through the side inlet port and is divided between two spin-on cans mounted end to end. Each can holds a size 160 Betamicron® (BN) low-collapse element, so the two elements share the flow and give a larger dirt-holding area than a single can of the same size. Clean oil leaves through the side outlet port. If the elements become loaded, or the oil is cold and thick at start-up, the differential pressure rises until the 50 psid (3.4 bar) bypass valve opens. This protects the elements against collapse, which the datasheet rates at 80 psid (5.5 bar) for BN, P and AM media.
The A indicator code means the filter is supplied with the indicator port plugged. A static VMF indicator or a visual gauge can be added later. The datasheet notes that the maximum allowable working pressure of all MF, MFD and MFDS filters drops from 120 psi (8 bar) to 60 psi (4 bar) when VMF indicator types B, BM, E, ES, GC, LE or LZ are used.
Dimensions and installation data from the datasheet
| Item | MFD 160 value |
|---|---|
| Overall length | 16.73 in (425.05 mm) |
| Inlet and outlet ports | 1 1/2 in NPT with 2 in SAE Code 61 flange (or 1 7/8–12UN SAE-24 port) |
| Mounting holes | 3/8–16UNC-2B |
| Gauge port | 1/8 in NPT |
| Clearance for element removal | 1.5 in (38.1 mm) |
| Weight including elements | 8.8 lb |
| Max. torque on flanged ports | 26 ft-lb (1/2–13 UNC bolts), per the MFDS note |
| Housing pressure (code A) | 120 psi (8.3 bar) |
Dimensions are given by HYDAC for general information and envelope size only. For a certified drawing, contact HYDAC through our team.
Selection & ordering guide
The MFD code builds up in a fixed order, and changing one field gives a different filter. Points to check before ordering:
- Size: 160 is rated 30 gpm (114 L/min) per can; the 180 is rated 60 gpm (227 L/min) per can and is 11 lb instead of 8.8 lb.
- Media and rating: BN elements are offered in 3, 5, 10 and 20 µm. P (paper) and AM (water removal) media are also listed for size 160.
- Bypass: B3.4 (50 psid) is standard on BN and AM elements. B1.7 (25 psid) is standard on paper. KB (no bypass) is not available with NPT ports.
- Pressure code: A is 120 psi. Y is 60 psi, used when an E-type static pressure gauge is fitted, with a B1.7 bypass.
- Indicator: A (plugged) on this code; static VMF indicators are listed for sizes 80, 85, 160 and 180.
- Replacement elements: order two size 0160 elements of the same media and rating, for example 0160 MA 010 BN for a 10 µm BN element (confirm the exact element code with HYDAC).
If you send us the nameplate or the old part number, our team can help confirm the correct ordering code for the MFDBN160AULF10A1.1/16-3B3.4 or an equivalent HYDAC model.
Installation & maintenance
- Fit the filter only on hydrocarbon-based fluids that are compatible with NBR seals, aluminum and steel. The datasheet says MF filters are not for high-water-based fluids or phosphate esters.
- Keep the fluid temperature between –10 °C and +100 °C (14 to 212 °F). HYDAC asks to be consulted for use below –10 °C.
- Respect the 26 ft-lb maximum bolt torque on SAE flange connections to avoid damaging the aluminum head.
- Leave at least 1.5 in (38.1 mm) below each can for removal.
- Change both elements at the same time, lubricate the seals with clean oil and tighten by hand as described for spin-on elements.
- Fill the system and bleed air before running at full flow.
Typical applications in Oman & the GCC
HYDAC lists agricultural, automotive, construction, gearbox, industrial, pulp and paper and steel industry applications for the MF family. In Oman and the GCC the MFDBN160AULF10A1.1/16-3B3.4 suits return lines and off-line kidney-loop circuits on power units, gearbox lubrication systems, mobile and construction machinery and industrial presses, where hot ambient conditions and dust make reliable filtration important.
Why source the MFDBN160AULF10A1.1/16-3B3.4 from Seven Star LLC
Seven Star LLC supplies HYDAC filters, elements and indicators across Oman and the GCC. Send us the model code, flow rate, fluid and required micron rating to request a quote, and our team can help confirm the correct ordering code and matching replacement elements.
Datasheets & Documents
- Datasheet Hydac MF, MFD and MFDS spin-on filter datasheet (FIL1907, USA edition) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
FAQ
Questions about the Hydac MFDBN160AULF10A1.1/16-3B3.4 Duplex Spin-On
Answers from our engineering team on installation, compatibility and integration.
01What does MFD mean?
A dual-head spin-on filter with two elements mounted end to end.
02What flow does the MFDBN160AULF10A1.1/16-3B3.4 handle?
30 gpm (114 L/min) per the catalogue item.
03What is the working pressure?
8 bar (120 psi).
04What is the bypass setting?
50 psid (3.4 bar), code B3.4.
05What is the filter rating?
10 micron, using a Betamicron low-collapse element.


















Reviews