- Automation & ControlView all 2,718 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Hydac
Hydac EY-1356 Metal Particle Contamination Sensor for Oil
Description
Hydac EY-1356 magnetic metal particle contamination sensor
The Hydac EY-1356 is a simple, robust warning sensor for hydraulic systems and gearboxes. It does not count particles or give a cleanliness class. Instead, a permanent magnet on the measuring face attracts ferromagnetic wear particles from the oil flowing past. As particles collect they form a conductive bridge between the magnet and an adjacent metal contact, and the electrical resistance across the sensor falls with the amount of debris gathered. A control system or relay evaluates that resistance and raises a warning or stops the machine before bearings or gears are seriously damaged. Seven Star LLC supplies Hydac products in Oman and the GCC as an independent supplier in Muscat.
EY-1356 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Hydac / EY-1356 (data sheet EN 18.602.3/08.21) |
| Principle | Permanent magnet collects ferromagnetic particles; resistive bridge between magnet and contact |
| Maximum voltage | 30 V DC |
| Maximum current | 200 mA |
| Maximum oil pressure (absolute) | 16 bar |
| Magnet retention force | About 1.5 N |
| Ambient temperature | -25 to +90°C |
| Protection | Deutsch DT04 2-pole: IP 67; integrated connector EN 175301-803 (ISO 4400): IP 65; M12x1 2-pole: IP 67 / IP 69K |
| Mechanical connections | M14x1.5, M18x1.5, M22x1.5, M26x1.5, M33x2, 7/8-14UNF-2A, G3/4, G1/2, G1/4 (depending on electrical version) |
| Maximum tightening torque | M14x1.5: 15 Nm; M18x1.5: 25 Nm; M22x1.5: 60 Nm; M26x1.5: 70 Nm; M33x2: 140 Nm |
| Seal | NBR seal ring to DIN EN ISO 9974-2 supplied |
| Mounting position | Recommended upside-down, with connector or cable exit pointing down |
How the EY-1356 provides an early warning of wear
Wear metals in oil, such as steel from gears, bearings and pump parts, are ferromagnetic and are drawn to the magnet in the sensor. Early in the life of a machine there are few particles and the contact stays open. As wear rises, the magnet picks up more debris and the particles form a bridge across the magnetic faces, so the resistance drops. The data sheet describes evaluating this ohmic resistance to activate a warning function or to switch the system off. This kind of sensor is therefore a threshold device, similar to a magnetic chip detector, and it fits where a simple alarm is wanted more than a number.
Because it responds only to ferromagnetic debris, it does not detect non-magnetic particles such as dust, sand, aluminium, bronze or rubber. It complements, but does not replace, particle counters like the Hydac CS 1000 or CS 2000 or periodic oil analysis. Think of it as an inexpensive tripwire for gross wear in gearboxes and hydraulic circuits.
Electrical and mechanical versions of the EY-1356
The data sheet lists three electrical connections and many thread sizes, and each combination has its own part number. With the EN 175301-803 (DIN 43650, ISO 4400) connector the numbers are 3836591 for M14x1.5, 3829087 for M18x1.5, 3829086 for M22x1.5, 3829088 for M26x1.5, 3829089 for M33x2, 3836592 for 7/8-14UNF-2A and 3951612 for G3/4. The Deutsch DT04 2-pole strand version uses numbers such as 3836593 (M14x1.5), 3836635 (M18x1.5), 3829090 (M22x1.5), 3647788 (M26x1.5) and 3829092 (M33x2). The M12x1 4-pole versions have numbers from 3886876 (M14x1.5) upward, and also include G1/2 (4169753) and G1/4 (4173036). Mating connectors are supplied only for the EN 175301-803 version; the Deutsch and M12 versions need a separate mating connector.
Pin connections and signal evaluation
All versions have two sensing terminals, called external magnet and internal magnet, and reverse polarity is possible, so the two wires can be connected either way. On the 14 mm version, the external ring magnet is connected to the housing and so is at ground potential, which has to be considered when the sensor is wired to a floating circuit. The sensor is a passive resistive device with a limit of 30 V DC and 200 mA, so it should be connected to a suitable evaluation input, a relay, a PLC digital input with a threshold, or an interface module, and not directly to a lamp or heavy load.
Where EY-1356 fits in a machine or system
Typical fitting positions are in a return line, a gearbox oil sump or a pipe through which the oil circulates, where there is enough flow past the magnet for particles to be carried to it. Oil stop valves are available as accessories to allow the sensor to be changed without draining the system: the data sheet lists M26x1.5, M42x2 and M48x2 types with order numbers 4589833, 4589834 and 4589956. For better monitoring, the EY-1356 can be fitted together with a CS sensor and a temperature sensor, and the signals can be handled in the same PLC.
Selection and ordering checklist for EY-1356
- Thread: choose from M14x1.5 to M33x2, UNF, G3/4, G1/2 and G1/4 to suit the port.
- Electrical connection: EN 175301-803, Deutsch DT04 strands or M12x1, and whether the mating connector is needed.
- Protection class: IP 65 for the plug-in connector, IP 67 for DT04, IP 69K for M12 versions.
- System oil pressure, which must not exceed 16 bar absolute.
- Evaluation device and the resistance threshold that sets the alarm.
- Oil stop valve for easy cleaning of the sensor in service.
Installation and maintenance of the EY-1356
Mount the sensor with the connector pointing downwards where possible, as the data sheet recommends, which also keeps the cable or plug from collecting drips. Use the supplied NBR seal ring and respect the maximum tightening torque for the thread size. After an alarm, remove the sensor, wipe the magnetic faces clean and inspect the collected debris: a small amount of fine dust is normal after run-in, whereas coarse flakes or chips mean a component should be inspected. Record the alarm date, and check the oil for further evidence before resetting.
EY-1356 applications in Oman and the GCC
Gearboxes on pumps, fans and cooling tower drives, hydraulic power units and mobile equipment working in hot dusty conditions suffer wear that is hard to see from outside. A magnetic warning sensor costs little compared with a gearbox replacement, and it is a practical alarm on remote installations, because the alarm can be sent to the PLC as a simple contact. High ambient temperatures up to +90°C are covered by the data sheet, but the oil temperature itself should be checked against the seal material.
Information to send with an EY-1356 RFQ
- Part number from the order table, or thread and electrical connection.
- Oil type, pressure and temperature at the fitting point.
- Evaluation input type and mating connector needs.
- Oil stop valve and quantity.
Documents and quotation
The Hydac EY-1356 data sheet is attached on this page with the technical data, dimensions and order table.
Send the thread and connector requirement and Seven Star LLC will confirm the right EY-1356 part number and quote supply to Oman and the GCC.
Datasheets & Documents
- Datasheet Hydac EY-1356 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
FAQ
Questions about the Hydac EY-1356 Metal Particle Contamination Sensor
Answers from our engineering team on installation, compatibility and integration.
01What does the Hydac EY-1356 detect?
It detects ferromagnetic metal particles in oil. A permanent magnet collects wear debris, which forms a conductive bridge, and the falling resistance gives an early warning of wear in bearings and gears.
02Can the EY-1356 count particles or give an ISO class?
No. It is a threshold warning device, not a particle counter. For cleanliness classes use the Hydac CS 1000 or CS 2000 ContaminationSensor.
03What is the maximum pressure and temperature for the EY-1356?
The maximum oil pressure is 16 bar absolute and the ambient temperature range is -25 to +90°C. The maximum voltage is 30 V DC and the maximum current is 200 mA.
04Which thread sizes does the EY-1356 offer?
The order table lists M14x1.5, M18x1.5, M22x1.5, M26x1.5, M33x2, 7/8-14UNF-2A and G3/4, with G1/2 and G1/4 available in the M12 version. Each combination has a separate part number.
05Can the EY-1356 be changed without draining the system?
Hydac lists oil stop valves as accessories in M26x1.5, M42x2 and M48x2 sizes, which allow the sensor to be replaced or cleaned without draining the hydraulic system.


















Reviews