Georg Fischer Type 519 is the three way branched diaphragm valve of the GF 5-Series. Its body has a main run and a branch outlet with a single diaphragm, so one valve can take a tapping from a main line, divert or isolate a branch and provide a dead space free draw off. The body ends in butt fusion spigots and the size range is wide: main line from d20 (DN15) up to d160 (DN150, 6 inch). Seven Star LLC is an independent supplier serving Oman and the GCC.
What is special about the Georg Fischer Type 519
A normal tee plus a valve leaves a stub of stagnant liquid between the two. The Georg Fischer Type 519 integrates both, with the diaphragm weir right at the junction, so the branch can be isolated with virtually no dead leg. This is vital for ultrapure water loops, pharmaceutical and microelectronics service and chemical dosing where dead legs breed bacteria or crystallise. Body materials are PVDF-HP and PEEK at both pressure levels and PP-H and PP-N at PN10.
Data table for Georg Fischer Type 519
| Item | Datasheet value |
|---|---|
| Connection | Butt fusion spigots, 3-way branched valve |
| Main size range | d20 to d160, DN15 to DN150, 1/2 to 6 inch |
| Body materials PN10 | PP-H, PP-N, PVDF-HP, PEEK |
| Body materials PN16 | PVDF-HP, PEEK |
| Kv 100, d20 main and d20 branch | 57 l/min, 3 cubic metres per hour (Cv 4) |
| Kv 100, d32 main and d32 branch | 231 l/min, 14 cubic metres per hour (Cv 16) |
| Kv 100, d63 main and d40 branch | 610 l/min, 37 cubic metres per hour (Cv 42) |
| Kv 100, d63 main and d63 branch | 747 l/min, 45 cubic metres per hour (Cv 52) |
| Kv 100, d160 main and d63 branch | 498 l/min, 30 cubic metres per hour (Cv 34) |
| Pressure levels | PN10 and PN16, depending on body and housing nut material |
| Housing nut | PPGF 30 orange as standard; PPSGF40 black for water applications with PN16 |
| Diaphragm materials | NBR, EPDM, PTFE, FKM |
| Gasket materials | EPDM, FKM |
| Temperature, PVC-U | 0 to 60 degrees C |
| Temperature, PVC-C and PP | 0 to 80 degrees C |
| Temperature, ABS | Minus 30 to plus 60 degrees C |
| Temperature, PVDF and PEEK | Minus 20 to plus 140 degrees C |
| Product standard | EN ISO 16138 |
| Test standards | ISO 9393-2 and EN 12266-1, leakage rate A |
Reading the branch flow table
The Kv value depends on both the main line size and the branch size, and the datasheet lists dozens of combinations. For example, a d25 main with a d15 branch gives 80 l/min, while a d63 main with a d63 branch gives 747 l/min. A big main with a small branch gives only a low flow because the branch bore limits it. Always check the table for the exact pair of d1 and d3 sizes you plan to order.
How Georg Fischer Type 519 differs from the straight through 5-Series valves
The 514, 515 and 517 are two way valves limited to d63. The Georg Fischer Type 519 is the only member that reaches d160 on the main line, and the only one with butt fusion spigots as its single connection type. Its material list is shorter and strongly aimed at high purity and chemical service: PP and PVDF-HP and PEEK, with no PVC, no ABS and no PVC-C in the table.
Applications in Oman and GCC plants
Use it for sampling points on desalination permeate, take off valves on circulating ultrapure loops, dosing injection points, and branch isolation on chemical headers. Where a dedicated three way valve replaces a tee and valve, the space and welds saved on a crowded skid can be significant.
Welding and installation
Butt fusion needs a proper welding machine, matched wall thickness and a trained operator, following the pipe maker’s parameters. Support the body so the branch is not loaded by hoses or instrument lines. Mount the valve with the handwheel accessible and keep the branch drainable to retain the dead space free advantage.
Service, spares and automation
The diaphragm is the wear part, and the housing nut gives access to it in place. The valve takes the same DIASTAR and e-DIASTAR actuators as the other 5-Series valves, so an automatic sampling valve is possible. Spare part and accessory lists are given in the datasheet.
Standards and approvals
The 5-Series follows EN ISO 16138, is tested to ISO 9393-2 and EN 12266-1 with leakage rate A, and lists ACS, FDA and DIBt approvals, with the note that some certification is temporarily unavailable during requalification.
Hygiene and ultrapure water practice
In high purity systems, the Georg Fischer Type 519 serves as a sampling and take off point that does not create a dead leg. Keep the branch short, install the branch pointing down or sideways so it drains, and flush it as part of the regular sanitisation routine. PVDF-HP and PEEK are well suited to hot water sanitisation and to ozone or peroxide cleaning solutions, while PP-H is used for cold, lower cost loops. Use the diaphragm material that matches the sanitising chemical, with PTFE faced diaphragms often chosen for the harshest media.
Planning a branch layout
When laying out the system, decide which port is the inlet and which the branch before ordering, because the datasheet’s flow table is read by main size and branch size. Leave clear space for the handwheel, plan supports so the branch pipe is not hanging from the valve, and mark the valve on the isometric drawing with its type and size. For long mains with many tappings, keep a short list of the branch Kv values, because the sum of all open branches can exceed the capacity of the main and starve the farthest user.
Related items you may also need: GF Type 546 Pro Linear Thermoplastic Ball Valve | GF Type 567 Wafer Thermoplastic Butterfly Valve | GF Signet 3-2551 Magmeter Insertion Electromagnetic Flow Sensor | All Georg Fischer products.
Documents and quotation
The GF datasheet for the Georg Fischer Type 519 is attached, including the full branch flow table. Send your RFQ with the Georg Fischer Type 519 main and branch sizes, body material, quantity and delivery location in Oman or the GCC.
Other Models in the Gf 5series Range
Seven Star LLC supplies models from the Gf 5series range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Georg Fischer Type 514 Manual Diaphragm Valve with Unions | Globe Valves | View details |
| Georg Fischer Type 515 Spigot End Diaphragm Valve | Globe Valves | View details |
Datasheets & Documents
- Datasheet Georg Fischer Type 519 Three-Way Diaphragm Valve Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Georg Fischer (GF) is a Swiss industrial group founded in 1802, when Johann Conrad Fischer bought a mill near Schaffhausen and turned it into a foundry. In 1864 his grandson Georg Fischer began making malleable iron fittings, introducing the GF fish trademark, and piping is one of the company's oldest businesses. GF Piping Systems makes plastic and metal piping systems, valves and Signet flow and water quality instruments.
Seven Star LLC, an independent supplier in Oman, lists the GF Signet 3-2551 Magmeter insertion electromagnetic flow sensor and the GF Signet 8550-1 flow transmitter.
Georg Fischer company profile
| Founded | 1802, Schaffhausen, Switzerland |
|---|---|
| Founder | Johann Conrad Fischer |
| Headquarters | Schaffhausen, Switzerland |
| Piping business | Fittings since 1864 |
| Product families | Type 546 ball valves, Type 567 butterfly valves, Signet flow sensors and transmitters, thermoplastic pipes and fittings |
Milestones
- 1802: Johann Conrad Fischer founds the company.
- 1864: GF begins making malleable iron fittings.
GF Signet instruments listed here
The 3-2551 Magmeter is an insertion flow sensor: it is mounted through a fitting in the pipe wall, has no moving parts and needs a liquid with some electrical conductivity. The 8550-1 is a flow transmitter that takes the signal from a Signet flow sensor and provides a display and outputs for the control system. Sensor, pipe fitting and transmitter are chosen together, because the fitting sets the insertion depth for a given pipe size and material.
Georg Fischer products we list
Ordering GF Signet parts: what we need
Copy the manufacturer part number from the label, which normally starts with 3- followed by the model and option digits. Add pipe size, pipe material, the fitting you have, the fluid and its conductivity, sensor body material, output required and cable length. Water treatment, desalination and chemical dosing sites in the GCC often have older Signet transmitters; if a model is no longer produced we ask for the manufacturer's current replacement, which for the 8550 is listed by distributors as the Signet 9900.
Facts checked against the Historical Dictionary of Switzerland and GF histories, October 2026.
Browse Georg Fischer products by category: Flowmeters.
FAQ
Questions about the Georg Fischer Type 519 Three-Way Diaphragm Valve
Answers from our engineering team on installation, compatibility and integration.
01What is Georg Fischer Type 519?
It is a three way branched manual diaphragm valve with butt fusion spigots, part of the GF 5-Series.
02What sizes does Georg Fischer Type 519 cover?
The main line runs from d20 to d160, which is DN15 to DN150 or 1/2 to 6 inch.
03Which body materials suit Georg Fischer Type 519?
PP-H, PP-N, PVDF-HP and PEEK at PN10, and PVDF-HP and PEEK at PN16.
04Why use Georg Fischer Type 519 instead of a tee and valve?
The weir sits at the junction, which removes the dead leg and keeps the branch dead space free and drainable.
05How is flow in Georg Fischer Type 519 specified?
Kv depends on both main and branch size; for instance d63 main with d63 branch gives 747 l/min.