Hydraulic presses, power packs and injection machines subject a pressure sensor to shock, vibration and pressure peaks that would shorten the life of a lighter transducer. The Gefran KS-E-E-C-B04C-M-V is the 400 bar, 2-wire 4 to 20 mA version of the KS compact transmitter, built from stainless steel around a thin-film sensing element deposited on a stainless steel diaphragm. The code appears as the worked example in the manufacturer datasheet. Seven Star LLC is an independent supplier serving Oman and the GCC and supplies the Gefran KS-E-E-C-B04C-M-V against that decoded specification.

Reading the Gefran KS-E-E-C-B04C-M-V code

  • KS: compact pressure transmitter family with SIL 2 certification supplied as standard.
  • E (first): output signal 4 to 20 mA, two wires.
  • E (second): pressure connection G 1/4 gas male, DIN 3852-E.
  • C: electrical connection by 4-pin microDIN connector (EN 175301-803 Form C, also called P8).
  • B04C: measuring range 0 to 400 bar.
  • M: non-linearity class plus or minus 0.25 percent of full scale, BFSL.
  • V: fast response time, less than 1 millisecond.

The ordering line also ends with a version field: 000 for the standard version or 00U for the cULus listed version, which is available on request. Confirm that field on the nameplate if UL listing matters to your project.

Performance of Gefran KS-E-E-C-B04C-M-V

Parameter Datasheet value
Range 0 to 400 bar
Overpressure / burst pressure at 400 bar 800 bar / 1500 bar
Non-linearity (BFSL) Plus or minus 0.15 % FS typical, 0.25 % FS maximum
Hysteresis 0.1 % FS typical, 0.15 % FS maximum
Repeatability Plus or minus 0.025 % FS typical, 0.05 % FS maximum
Accuracy at room temperature Less than plus or minus 0.5 % FS (IEC 61298-2)
Output 4 mA zero, 20 mA full scale
Supply for current output 10 to 30 Vdc, maximum 35 mA
Response time 10 to 90 % FS Less than 1 ms
Warm-up time Less than 30 s
Long-term stability Less than 0.2 % FS per year
Temperatures Process -40 to 125 C, ambient -40 to 105 C, compensated -20 to 85 C, storage -40 to 125 C
Temperature effect (zero and span) 0.01 % FS per C typical, 0.02 % FS per C maximum
Shock / vibration 100 g for 11 ms (IEC 60068-2-27); 20 g from 10 to 2000 Hz (IEC 60068-2-6)
Protection IP65 with mating microDIN connector fitted (cULus listing applies to this connector type)
Materials Wetted parts AISI 430F and 17-4 PH; housing AISI 304
Weight 80 to 120 g nominal

How the 400 bar KS differs from other KS ranges and outputs

The KS range covers 1, 1.6, 2, 2.5, 4, 6, 10, 16, 20, 25, 40, 60, 100, 160, 200, 250, 400, 600 and 1000 bar. Overpressure grows with range: 6 bar at 1 to 2 bar, 200 bar at 100 bar, 400 bar at 200 bar, 800 bar at 400 bar and 1200 bar at 600 and 1000 bar. Burst pressure follows the same trend, and at 400 bar it is 1500 bar. Ranges up to 2.5 bar are not available with SIL or UL certification, and the 0-5 V and 0-10 V outputs are not available with SIL certification. Other outputs exist, such as 0.1 to 5.1 V, 0.1 to 10.1 V, 1 to 5 V, 1 to 6 V, 1 to 10 V, 0.2 to 10.2 V and ratiometric 0.5 to 4.5 V, but this part number is the current output and therefore draws up to 35 mA instead of 15 mA, and requires a supply of 10 to 30 V. Ranges of 60 bar and below need a vented cable or mating connector for atmospheric reference, which is not a concern at 400 bar.

Where the KS-E-E-C-B04C-M-V is used

The datasheet recommends the KS for industrial uses and especially hydraulics: presses, pumps, power packs and fluid power with high shock, vibration, pressure and temperature peaks. In Oman and the GCC, 400 bar is typical for hydraulic presses, wellhead service units, hydraulic torque and tensioning equipment, mobile workshop hydraulics and test benches for pumps and valves. The 4 to 20 mA output keeps the signal usable over long cable runs to a PLC panel and tolerates electrical noise better than low-level voltage outputs.

Installation and wiring

Thread the G 1/4 male port into the DIN 3852-E seat and tighten according to the seal type used. The housing should not be loaded by the electrical connection. A 2-wire loop needs a supply between 10 and 30 V and an allowed load shown in the datasheet load diagram. The device must be powered by a Class 2 or LPS supply, and if it is permanently connected to the machine an external switch or circuit breaker and overcurrent protection are required. Output short circuit and reverse polarity protection is included. The microDIN connector is a 4-pin Form C connector that must be tightened with its seal to reach IP65. Apply the full pressure only after the loop is wired, then check zero at 4 mA with the system vented.

Maintenance and calibration

Instruments from this manufacturer are calibrated against precision pressure equipment traceable to international standards. In service, check the output at zero pressure at each shutdown, inspect seals and the connector, and compare the reading with a reference gauge when the machine is tested. Long-term stability below 0.2 percent of full scale per year means a yearly check is usually adequate for hydraulic machine controls.

Selection checklist for the Gefran KS-E-E-C-B04C-M-V

Check that the working pressure peaks stay below 800 bar, that the process temperature stays within -40 to 125 C and that the medium is compatible with 430F and 17-4 PH stainless steel. Confirm the electrical connector against the cable assembly in your machine, because the microDIN type differs from the larger DIN Form A and the M12 type that exist for other codes of the same family. Confirm whether a cULus listed version is required.

Why a thin-film element suits hydraulic duty

The sensing element is a film deposited directly on the stainless steel diaphragm rather than a separate die. With surface-mount electronics and an all-stainless construction, the transmitter keeps its calibration through the vibration and pressure spikes that appear when a hydraulic valve shifts. For the Gefran KS-E-E-C-B04C-M-V the manufacturer quotes 0.025 percent typical repeatability and a response time under 1 ms, so a PLC sees pressure peaks that slower sensors would smooth out. Because the measuring range is operating pressure from 0.5 percent to 100 percent of full scale, a 400 bar unit is specified from about 2 bar upward.

Related items you may also need: Honeywell STG79S SmartLine STG700 Gauge Pressure Transmitter | JUMO SIRAS P21 DP SIL Differential Pressure Transmitter | Hydac HDA 4775-A-5000-000 High-Pressure Transducer 5000 psi | All Gefran products.

Documents and quotation

The manufacturer datasheet showing this ordering example is attached to this page. To receive an offer, send the RFQ with the part number, quantity, whether a cULus version is needed and the delivery location in Oman or the GCC. If you are replacing an installed sensor, include a photograph of its label.

Datasheets & Documents
  • PDF Datasheet Gefran KS-E-E-C-B04C-M-V Pressure Transmitter 400 bar Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Gefran is an Italian maker of sensors, controllers and power control equipment for industrial process and machine automation. The company traces its start to 1969, when its first workshop opened in Provaglio d'Iseo, in the province of Brescia, to build electric panels for machines that process plastics. In the 1970s Gefran introduced the Adamello controller, later renamed the 1000 model, and in the 1980s it added sensor production. The company has been listed on the Milan stock exchange since 1998 and today reports about 800 employees in its production sites and 17 sales offices worldwide.

Gefran company profile

Founded 1969, Provaglio d'Iseo (Brescia), Italy
Headquarters Via Sebina 74, Provaglio d'Iseo (BS), Italy, with the main production plant
Ownership Listed on the Milan stock exchange since 1998
Core technology Pressure, position, temperature and force sensors; PID controllers; solid state relays and thyristor power controllers; automation platforms
Typical applications Plastics extrusion and injection, metal processing, heating processes, glass, food, wood, packaging, energy and mobile machines
Standards UL 508 short-circuit ratings on power controllers, SIL 2 pressure transmitters (IEC/EN 62061), IO-Link and NAMUR NE21/NE43 on selected sensors, CE and RoHS

Milestones

  • 1969: The first Gefran workshop opens in Provaglio d'Iseo to produce electric panels for plastics machinery.
  • 1970s: The Adamello controller, later called the 1000 model, becomes an industry reference.
  • 1980s: Production expands to sensors and the company internationalises.
  • 1998: Gefran is listed on the Milan stock exchange.
  • Today: Sensors, controllers, power control and automation platforms are sold through 17 sales offices and a worldwide dealer network.

How Gefran fluid-free melt pressure sensing works

Measuring the pressure of molten polymer at more than 300 C used to mean a capillary filled with mercury or sodium-potassium alloy. The Gefran IMPACT series removes the fill fluid. Process pressure bears on a thick stainless steel diaphragm, which the datasheet says can be up to 15 times thicker than in traditional melt sensors, and the load passes directly to a micro-machined silicon element. Piezoresistors on that element change resistance with strain, and on-board electronics turn the change into a 4 to 20 mA, voltage or digital signal with 16-bit resolution. Because the element barely deflects, the housing can be rugged, diaphragm temperatures reach 350 C and there is nothing to leak into the product. When selecting a probe, match the range to the die pressure with margin, choose the stem length for the barrel depth and add the relay version where an overpressure trip is required.

Where Gefran products are used in Oman and the GCC

In the Gulf the typical Gefran installation is a process that must hold temperature or pressure with little drift: plastic pipe and film extruders, food ovens and dryers, electric furnaces, packaging machinery, test benches and hydraulic presses. Controllers and solid state relays regulate heater zones, while pressure transmitters watch die pressure or hydraulic circuits, and replacements are often requested when a machine is refurbished or an older instrument is no longer easy to find.

Gefran models we list

Family Examples
PID temperature controllers 600, 1300
Solid state relays GRP, GRZ-3P-3S
Thyristor power controllers GTF-25-480
Melt pressure transmitters IE1S-6-M-B07C-1-4-D-P
Industrial pressure transmitters KS-E-E-C-B04C-M-V

Ordering Gefran products: what we need

Send the complete order code from the nameplate or the drawing, the quantity and the delivery point. For controllers include the output, input and supply digits; for relays the rated current, voltage and control type; for pressure transmitters the range, thread, connector and output. Seven Star LLC is an independent supplier serving Oman and the GCC and will confirm the code against the manufacturer datasheet before quoting.

Facts checked against the Gefran group history pages and Gefran product datasheets, November 2026.

FAQ

Questions about the Gefran KS-E-E-C-B04C-M-V Pressure Transmitter 400

Answers from our engineering team on installation, compatibility and integration.

01What does the code Gefran KS-E-E-C-B04C-M-V describe?
A KS pressure transmitter with 4-20 mA 2-wire output, G 1/4 gas male pressure connection, 4-pin microDIN electrical connector, 0 to 400 bar range, 0.25 percent non-linearity class and less than 1 ms response time.
02What is the overpressure and burst pressure of the Gefran KS-E-E-C-B04C-M-V?
For the 400 bar range the datasheet gives an overpressure limit of 800 bar and a burst pressure of 1500 bar, without degrading performance below the overpressure limit.
03What supply does Gefran KS-E-E-C-B04C-M-V need?
10 to 30 Vdc for the 4-20 mA current output, with maximum current absorption of 35 mA. It has output short-circuit and reverse polarity protection.
04Is Gefran KS-E-E-C-B04C-M-V SIL certified?
The KS family is SIL 2 certified according to IEC/EN 62061 as standard, except for the 0-5 V and 0-10 V outputs and for ranges up to 2.5 bar, which also lack UL listing. A cULus listed version is available on request.
05What shock and vibration can Gefran KS-E-E-C-B04C-M-V tolerate?
The datasheet states mechanical shock of 100 g for 11 ms to IEC 60068-2-27 and vibration of 20 g from 10 to 2000 Hz to IEC 60068-2-6, which suits hydraulic presses and power packs.