Brand:

Gefran 1300 PID Temperature Controller 1/4 DIN

Description

Overview

When an operator has to read a barrel or oven temperature from several metres away, panel size matters more than anything else on the datasheet. The Gefran 1300 answers that with a 96 x 96 mm (1/4 DIN) PID controller whose process-variable display uses 20 mm green digits, the largest in the Gefran 1200/1300 pair. Behind the Lexan faceplate, which keeps IP65 protection, sit the same universal input, up to four outputs and optional serial line as its smaller sibling. Seven Star LLC is an independent supplier serving Oman and the GCC and offers the Gefran 1300 against your exact output, input and power-supply codes.

Gefran 1300 at a glance

  • Universal main input configured from the faceplate, with 0.2 % of full scale plus or minus 1 digit accuracy and 120 ms acquisition time.
  • Up to four configurable outputs, a 24 V supply for outside transmitters and an analogue retransmission option.
  • Up to two isolated digital inputs, or one digital input plus a 50 mA ac current-transformer input for heater monitoring.
  • Three fully configurable alarms, loop-break alarm, heater-break or probe short-circuit alarm.
  • Self-tuning, auto-tuning, soft-start, bumpless manual/automatic transfer, double setpoint, setpoint ramp and timed output.
  • Optional optically isolated serial line, current loop or RS485, with MODBUS RTU up to 19200 baud.

Technical data for Gefran 1300

Item Gefran 1300 value
Housing 96 x 96 mm (1/4 DIN), depth 100 mm
Displays PV 20 mm green, SV 13 mm green, four red output lamps, three programmable lamps
Faceplate IP65 with Lexan membrane
Weight 400 g (the 1200 weighs 320 g)
Thermocouples J 0-1000 C, K 0-1300 C, R and S 0-1750 C, T -200 to 400 C, B 44-1800 C, E -100 to 750 C, N 0-1300 C, custom -1999 to 9999
RTD (3 wire) Pt100 -200 to 850 C, JPT100 -200 to 600 C
Thermistors PTC 990 ohm -55 to 120 C, NTC 1 kohm -10 to 70 C
Linear scales 0-60 mV, 0-10 V, 0-5 V, 0-1 V, 0-20 mA, 4-20 mA with 32-segment custom linearisation
Digital inputs IN1 / IN2 PNP 4.7 kohm, 24 V, 5 mA, 1500 V isolation, or voltage-free contact
CT input 50 mA ac, 50/60 Hz, Ri 10 ohm
Relay 5 A, 250 Vac / 30 Vdc, cos phi = 1
Logic 24 Vdc, Rout 100 ohm (10 V at 20 mA)
Triac 24 to 240 Vac plus or minus 10 %, 50/60 Hz, 1 A maximum, I2t = 128 A2s
Supply 100 to 240 Vac/dc plus or minus 10 %, maximum 18 VA; 11 to 27 Vac/dc, maximum 11 VA on request
Ambient 0 to 50 C operating, -20 to 70 C storage, humidity 20 to 85 % non-condensing
Approvals c/UL/US file E198546; EN 61000-6-2, EN 61000-6-3, EN 61010-1

How Gefran 1300 differs from the 1200 and the 600

All three share the control algorithms, but the physical and electrical details differ in ways that matter when you order. The 1300 is 96 x 96 mm with 400 g weight, the 1200 is 48 x 96 mm with 320 g and the compact 600 is 48 x 48 mm with 160 g. PV digit height grows from 10 mm on the 1200 to 20 mm on the 1300, while the setpoint digits are 10 mm and 13 mm. Unlike the 600, the 1300 datasheet lists only MODBUS RTU communications and gives a separate field for IN1, IN2 and the current-transformer input. The 1300 also has a dedicated OUT4 field that can be relay or logic, and a continuous or retransmission option on output 3.

Order-code fields explained

The datasheet builds the code from the model number, output 1 (relay), output 2 (relay R, logic D or triac T), output 3 (none, relay, logic, continuous C or analogue W), output 4 (none, relay or logic), the digital communication digit (0 none, 2 RS485), the power-supply digit (0 for 11 to 27 Vac/dc, 1 for 100 to 240 Vac/dc) and a two-digit input field (00 none, 01 for IN1 plus IN2 NPN/PNP, 02 for IN1 plus the 50 mA CT input). Because the manufacturer notes that availability of each combination must be confirmed, we ask buyers to confirm the full order code on the nameplate rather than guess one from the table.

Where the 1300 earns its panel space

The application list in the datasheet reads like a tour of thermal processing: extrusion lines, plastic injection presses, heat punches, rubber presses, packaging and packing machines, polymerisation and synthetic fibre plants, food plants, die-casting, cooling plants, climatic test cells, ceramic dryers, ovens and painting plants. In Oman and the wider GCC the large display is popular on heat-treatment ovens at fabrication yards, on bitumen and resin heating tanks, on plastic film extruders and on thermal test benches at laboratories, where a technician reads the value from the walkway rather than at the door.

Selection tips before you order

Choose the 1300 over the 1200 when readability or panel width is the constraint, and over the 600 when you need the extra digital input or the larger terminal block. Choose the output for the actuator: a logic output drives a solid state relay, a relay output drives a contactor within its 5 A rating, a triac suits small solenoid loads and a continuous 0-10 V or 0/4-20 mA output feeds a thyristor power controller. If heater health matters, order the code with IN1 plus the CT input and enable the heater-break alarm.

Installation and first start-up

Mount the unit vertically in a 96 x 96 panel opening, leaving room behind for 100 mm depth plus wiring. Keep sensor wiring separate from power wiring, use the screw terminals with appropriately sized conductors and confirm the supply digit before energising. The instrument ships with an EASY configuration that shows only the parameters relevant to the ordered model; set the setpoint and alarms, start self-tuning with the dedicated key and then review cycle time, power limits and the soft-start time. Parameters are grouped in blocks such as CFG, Inp and Out, so everything is found in one place.

A PC kit with a cable and guided program is available; the datasheet names it WINSTRUM, while newer configuration work is done with the GF_eXpress utility from the same manufacturer. If you need to read process values over the serial line, set the node address, baud rate and protocol before connecting the PLC.

Service and spare planning

The internal fuse is not user serviceable, so stock a complete spare controller for critical lines instead of a fuse. Record the parameter set, inspect terminals during shutdowns and keep the case within its 0 to 50 C ambient limit. Because the Gefran 1300 is configured entirely from the keys, a replacement can be commissioned in minutes if the old settings were written down.

Related items you may also need: Autonics TC4Y-14R 72×36 PID Temperature Controller, 1 Alarm | Woodward easYgen-3500-5 Genset Controller (5 A CT) | JUMO miroVIEW Smart Digital Panel Indicator, Type 701580 | All Gefran products.

Documents and quotation

The manufacturer datasheet covering the Gefran 1200 and Gefran 1300 is attached to this page. For a quotation, send the RFQ with the part number, the output, input and power-supply configuration, the quantity and the delivery location in Oman or the GCC. A photograph of the nameplate of the controller you are replacing helps us confirm the exact code before we quote.

Datasheets & Documents
  • PDF Datasheet Gefran 1300 PID Temperature Controller 1/4 DIN Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Gefran is an Italian maker of sensors, controllers and power control equipment for industrial process and machine automation. The company traces its start to 1969, when its first workshop opened in Provaglio d'Iseo, in the province of Brescia, to build electric panels for machines that process plastics. In the 1970s Gefran introduced the Adamello controller, later renamed the 1000 model, and in the 1980s it added sensor production. The company has been listed on the Milan stock exchange since 1998 and today reports about 800 employees in its production sites and 17 sales offices worldwide.

Gefran company profile

Founded 1969, Provaglio d'Iseo (Brescia), Italy
Headquarters Via Sebina 74, Provaglio d'Iseo (BS), Italy, with the main production plant
Ownership Listed on the Milan stock exchange since 1998
Core technology Pressure, position, temperature and force sensors; PID controllers; solid state relays and thyristor power controllers; automation platforms
Typical applications Plastics extrusion and injection, metal processing, heating processes, glass, food, wood, packaging, energy and mobile machines
Standards UL 508 short-circuit ratings on power controllers, SIL 2 pressure transmitters (IEC/EN 62061), IO-Link and NAMUR NE21/NE43 on selected sensors, CE and RoHS

Milestones

  • 1969: The first Gefran workshop opens in Provaglio d'Iseo to produce electric panels for plastics machinery.
  • 1970s: The Adamello controller, later called the 1000 model, becomes an industry reference.
  • 1980s: Production expands to sensors and the company internationalises.
  • 1998: Gefran is listed on the Milan stock exchange.
  • Today: Sensors, controllers, power control and automation platforms are sold through 17 sales offices and a worldwide dealer network.

How Gefran fluid-free melt pressure sensing works

Measuring the pressure of molten polymer at more than 300 C used to mean a capillary filled with mercury or sodium-potassium alloy. The Gefran IMPACT series removes the fill fluid. Process pressure bears on a thick stainless steel diaphragm, which the datasheet says can be up to 15 times thicker than in traditional melt sensors, and the load passes directly to a micro-machined silicon element. Piezoresistors on that element change resistance with strain, and on-board electronics turn the change into a 4 to 20 mA, voltage or digital signal with 16-bit resolution. Because the element barely deflects, the housing can be rugged, diaphragm temperatures reach 350 C and there is nothing to leak into the product. When selecting a probe, match the range to the die pressure with margin, choose the stem length for the barrel depth and add the relay version where an overpressure trip is required.

Where Gefran products are used in Oman and the GCC

In the Gulf the typical Gefran installation is a process that must hold temperature or pressure with little drift: plastic pipe and film extruders, food ovens and dryers, electric furnaces, packaging machinery, test benches and hydraulic presses. Controllers and solid state relays regulate heater zones, while pressure transmitters watch die pressure or hydraulic circuits, and replacements are often requested when a machine is refurbished or an older instrument is no longer easy to find.

Gefran models we list

Family Examples
PID temperature controllers 600, 1300
Solid state relays GRP, GRZ-3P-3S
Thyristor power controllers GTF-25-480
Melt pressure transmitters IE1S-6-M-B07C-1-4-D-P
Industrial pressure transmitters KS-E-E-C-B04C-M-V

Ordering Gefran products: what we need

Send the complete order code from the nameplate or the drawing, the quantity and the delivery point. For controllers include the output, input and supply digits; for relays the rated current, voltage and control type; for pressure transmitters the range, thread, connector and output. Seven Star LLC is an independent supplier serving Oman and the GCC and will confirm the code against the manufacturer datasheet before quoting.

Facts checked against the Gefran group history pages and Gefran product datasheets, November 2026.

FAQ

Questions about the Gefran 1300 PID Temperature Controller 1/4 DIN

Answers from our engineering team on installation, compatibility and integration.

01How large is the Gefran 1300 controller and its display?
The Gefran 1300 is a 96 x 96 mm (1/4 DIN) controller, 100 mm deep and weighing 400 g. The process variable is shown on 20 mm green digits and the setpoint on 13 mm digits.
02Which communication protocol does the Gefran 1300 use?
The 1200/1300 datasheet lists optically isolated 2/4-wire RS422/485 or current loop with the MODBUS RTU protocol, at 1200 to 19200 baud. The communication digit of the code is 0 for none and 2 for RS485.
03What digital inputs can be fitted to the Gefran 1300?
The input field offers none (00), IN1 plus IN2 NPN/PNP (01) or IN1 plus a 50 mA ac current-transformer input (02). The digital inputs are rated 24 V, 5 mA with 1500 V isolation.
04Can the Gefran 1300 control both heating and cooling?
Yes, it supports On/Off, P, PD and PID action for heating and cooling, with the cooling setpoint defined relative to the heating setpoint. Continuous outputs 0-10 V or 0/4-20 mA are intended for the heat/cool control output only.
05What power supplies are available for the Gefran 1300?
Standard is 100 to 240 Vac/dc plus or minus 10 % at up to 18 VA, and 11 to 27 Vac/dc at up to 11 VA is available on request. The code digit is 1 for the mains range and 0 for the low-voltage range.