Extech AN310 Large Vane CFM/CMM Anemometer and Psychrometer
Description
AN310 is the Extech large vane anemometer and psychrometer for HVAC airflow work. The 100 mm (4 in) vane measures air velocity from 0.2 to 30 m/s and calculates air volume in CFM or CMM from a duct area, while built-in sensors give air temperature, relative humidity, wet bulb and dew point. It stores up to 19,999 multi-point readings and offers timed averaging.
Duct and diffuser airflow with humidity in the same reading
A 4 in vane gives a steadier average than small vanes on larger ducts and grilles. The upper display shows air velocity or relative humidity and the lower display scrolls through air flow, temperature, wet bulb and dew point. Enter the duct area in square inches or square centimetres in setup and the meter converts velocity into CFM or CMM.
For diffusers the optional AN300-C airflow cone kit contains round (210 mm) and square (346 mm) adaptors, which the meter recognises automatically; it then uses the vane opening area rather than the setup value. Multi-point and timed average modes help with traverse readings across a duct.
Features stated in the datasheet and manual
- Velocity 0.2 to 30 m/s (40 to 5900 ft/min); airflow 0 to 99,999 CFM or CMM.
- Built-in NTC thermistors for air temperature, humidity, wet bulb and dew point; RH offset in setup.
- Min/Max, data hold, multi-point average to 19,999 points, timed average up to 19,999 seconds.
- Complete with four AAA batteries and hard case; auto power off after 20 minutes (can be disabled).
Technical specification
Measurement specification (manual)
| Parameter | Specification |
|---|---|
| Air velocity | 0.2 to 30 m/s, 0.01 m/s; ± (1.5 % reading + 0.3 m/s) |
| Air velocity (fpm) | 40 to 5900 fpm, 1 fpm; ± (1.5 % reading + 59 fpm) |
| Air flow | 0 to 99,999 m3/min (CMM) or ft3/min (CFM); area 0 to 99,999 square cm or square in |
| Air temperature and wet bulb | -20 to 60 C (-4 to 140 F), 0.1 resolution; ± 0.6 C from -20 to 50 C, ± 1.2 C from 51 to 60 C |
| Relative humidity | 0.1 to 99.9 % RH; ± 3 % RH (10 to 90 % RH), ± 5 % RH outside that range |
| Dew point | -5 to 60 C (23 to 140 F); ± 1.1 F from -5 to 122 F, ± 2.2 F from 123 to 140 F |
| Sampling rate | About 1 reading per second |
General specification
| Parameter | Specification |
|---|---|
| Display | Dual function 13 mm (0.5 in) 4-digit backlit LCD |
| Sensors | Angled vane arms with low-friction ball bearing; NTC precision thermistors |
| Power supply | Four 1.5 V AAA batteries; battery life above 40 hours |
| Operating conditions | 0 to 50 C; below 80 % RH; altitude up to 2000 m |
| Storage conditions | -10 to 50 C; below 90 % RH |
| Dimensions | Main instrument 269 x 106 x 51 mm; vane inner diameter 100 mm |
| Weight | About 725 g including battery and probe (manual); datasheet quotes 200 g for the meter only |
| Optional adaptors | AN300-C: round 210 mm and square 346 x 346 mm airflow cones |
Choosing between AN300, AN310 and AN320
The datasheet lists AN300 (thermo-anemometer), AN310 (adds humidity, wet bulb and dew point), AN320 (adds CO2 0 to 9999 ppm) and AN300-C (airflow cone and funnel adapters). The AN310 sits in the middle: choose it when psychrometric values are needed but CO2 is not.
The datasheet gives a temperature accuracy of 0.6 C; the manual breaks accuracy into ranges, which are listed above. Use the manual values for acceptance work.
Operating notes from the manual
Air must enter the vane from the rear of the meter, with the temperature and humidity sensors in the centre of the vane. To measure duct volume, measure the duct area first, enter it in setup mode and select CMM or CFM on the lower display. Do not use the area setting when a cone adaptor is attached.
Allow the meter about 30 minutes at room temperature if an out-of-range temperature error appears. Remove the batteries if the meter is stored for a long period.
Typical uses in Gulf HVAC work
Datasheet applications include HVAC, manufacturing, engineering, appliance testing and research and design. General engineering note: in hot, humid Gulf buildings, supply air velocity and dew point checks on AHU outlets, ducts and diffusers help verify balancing reports and spot condensation risk; hold the meter still and take several readings for a reliable average.
Related Extech items
For light level surveys see the LT300, for machine speed the 461995 tachometer, and for temperature the IR400. See the portable test and measurement category.
Field use and calibration notes
Vane anemometers are used in the region by HVAC contractors and maintenance teams to balance air systems, check air conditioning diffusers and grilles, and test fresh air rates in buildings. For duct and grille measurements, enter the correct area and take several readings across the face, or use the averaging function, as velocity varies across the opening. Keep the vane clean and protect it from dust. Arrange calibration at regular intervals.
Record the duct areas and readings, so later checks can be compared directly.
Information to send with an enquiry
- Measurement tasks and air velocities
- Calibration certificate requirement
- Quantity
Related Extech products: Extech PQ3450 3-Phase Power Analyzer and Datalogger, Extech IR400 Mini IR Thermometer with Laser Pointer, 332 C, Extech VB450 Pocket Vibration Meter, 10 Hz to 1500 Hz, Extech EX530A Heavy Duty True RMS Multimeter, 50000 Count, Extech LT300 Digital Light Meter, 400,000 Lux and Extech MA445 400 A True RMS AC/DC Clamp Meter with NCV.
Documents and quotation
For quotation, send your required quantity and destination. The Extech datasheet and user manual for AN310 are provided below the description on this page. Seven Star LLC works as an independent supplier from Muscat. Please compare code, ratings and options with the documents before you place an order; see also the category listing.
Datasheets & Documents
Reviews (0)
How would you rate this product? Cancel reply
About brand
Extech Instruments is an American brand of handheld test and measurement instruments, founded in the early 1970s in Waltham, Massachusetts. FLIR Systems acquired Extech in 2007 for about $40 million, and FLIR itself became part of Teledyne in 2021. Extech is based in Nashua, New Hampshire, and makes meters for electrical, environmental and HVAC testing.
Extech company profile
| Founded | Early 1970s, Waltham, Massachusetts |
|---|---|
| Headquarters | Nashua, New Hampshire (since 2011) |
| Ownership | Teledyne FLIR |
| Acquired by FLIR | 2007 |
| Product families | True RMS clamp meters and multimeters, insulation testers, power analysers, IR thermometers, light meters, vibration meters, sound, humidity and air quality meters |
Milestones
- 2007: FLIR Systems acquires Extech.
- 2011: Extech moves to Nashua.
- 2021: FLIR becomes part of Teledyne.
Meters, testers and inspection tools
The Extech range includes multimeters and clamp meters, insulation and resistance testers, power analyzers, thermometers, light and sound level meters, anemometers, tachometers, vibration meters, moisture meters, borescopes and water quality meters. Each datasheet and user manual lists ranges, accuracy, safety category and ordering codes, and many models are listed with NIST-traceable calibration versions ordered by adding -NIST to the part number.
Supply through Seven Star LLC
Seven Star LLC is an independent supplier in Muscat that quotes Extech products for projects in Oman and the GCC, with the official Extech datasheet and user manual attached to each product page.
Extech products we list
Facts checked against FLIR's 2007 announcement and published Extech histories, October 2026.
FAQ
Questions about the Extech AN310 Large Vane CFM/CMM Anemometer and
Answers from our engineering team on installation, compatibility and integration.
01What does the AN310 measure?
Air velocity, air flow (CFM or CMM from a duct area), air temperature, relative humidity, wet bulb and dew point.
02How accurate is the velocity reading?
The manual gives ± (1.5 % of reading + 0.3 m/s) over 0.2 to 30 m/s.
03Can it measure at diffusers?
Yes, with the optional AN300-C round and square airflow cone adaptors, which the meter recognises automatically.
04How many readings can it store for averaging?
Up to 19,999 points in multi-point average mode, or a timed average up to 19,999 seconds.
05Does Seven Star LLC act as an Extech distributor?
No. Seven Star LLC is an independent supplier in Muscat that sources Extech products on request.