- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Industrial Computers
- Servo Drives
- HMI Displays
- Motor Soft Starters
- Isolator & Barrier
- Pneumatic Cylinders
- Automation Software
- Machine Vision
- Robotics
Brand: TSI
TSI VelociCalc 5725 Rotating Vane Anemometer 100 mm
Description
A 100 mm vane head for open grilles and large diffusers
The TSI VelociCalc 5725 is a rotating vane anemometer with a 100 mm (4 in.) vane head that screws onto a handle and connects to a logging display unit. Where a hot-wire probe is fragile and directional, a vane head averages the flow over a larger area, which suits grilles, diffusers and open duct ends in HVAC commissioning.
The meter reads velocity from 0.25 to 30 m/s and temperature, calculates volumetric flow from a duct area you enter, and logs up to 12,700+ samples. Browse supporting instruments under Portable Test & Measurement.
Key points from the manual
- Flow set-up for round duct, rectangular duct and direct duct area (0 to 500 ft2, or 0 to 46.45 m2).
- Cont-key logging with a 1 second interval for a sweep measurement across an area.
- Optional articulating extension to angle the head, and optional Air Cone kit for small outlets.
- Menus for display set-up, settings, flow set-up, data logging and calibration; USB download through LogDat2.
Technical specification
Measurement
| Parameter | Specification |
|---|---|
| Velocity range | 50 to 6,000 ft/min (0.25 to 30 m/s) |
| Velocity accuracy | 1.0 % of reading plus or minus 4 ft/min (0.02 m/s) |
| Duct area entry | 0 to 500 ft2 (0 to 46.45 m2) |
| Volumetric flow | Function of actual velocity and duct area |
| Temperature | 5 to 45 C (40 to 113 F); accuracy 1 C (2 F); display step 0.1 |
| Vane head | 100 mm (4 in.) rotating vane, attached by screwing the handle into the head |
Logging, physical and power
| Parameter | Specification |
|---|---|
| Data storage | Over 12,700 samples; 100 test IDs; each sample holds up to fourteen measurements |
| Logging interval | Anywhere from 1 s to 1 h |
| Time constant | Set by the user (moving average) |
| Operating temperature (electronics) | 5 to 45 C (40 to 113 F) |
| Storage temperature | -20 to 60 C |
| Operating conditions | Rated to 4000 m and 80 % RH without condensation; IEC 664 pollution degree 1; overvoltage category II |
| Meter dimensions | 8.4 x 17.8 x 4.4 cm |
| Weight | 0.27 kg with batteries |
| Power | Four AA cells (supplied) or an optional 9 VDC 300 mA adapter drawing 4 to 18 W |
| Air Cone kit (optional) | Rectangular 285 x 235 mm (11.2 x 9.2 in.) and circular 180 mm (7.1 in.) cones |
Vane or hot-wire probe?
Pick the 5725 for large, low-turbulence supply or return openings where an averaged reading across the 100 mm head is helpful, and the 9545 or 9565 with a thermoanemometer probe for small openings and low velocities. The 5725 starts at 0.25 m/s, with accuracy stated as 1 % of reading plus 4 ft/min.
Using the 5725 on site
Screw the handle into the bottom of the vane head until secure and remove it after use so the head is not damaged. The optional articulating extension lets you lock the head at nearly any angle: unscrew the swivel bolt, set the elbow, then tighten the knurled knob beneath the head.
For an air volume balance slide the vane head into the Air Cone for supply or extract measurements. Use Cont-key mode with a 1 second log interval to take a sweep, and set a longer time constant if the display fluctuates. TSI recommends annual factory recalibration.
Data are organised as samples (all parameters stored at the same moment) grouped into Test IDs, with average, minimum, maximum and count calculated per Test ID; up to 100 Test IDs can be kept. Clean the case with a soft cloth and isopropyl alcohol or mild detergent, never immerse it, replace a broken enclosure or AC adapter immediately, and remove the batteries if the unit is stored for more than a month.
Applications in commissioning and maintenance
Typical uses are air balancing of office and hotel supply grilles, airflow at kitchen extract hoods and ventilation checks in plant rooms. Operating electronics range is 5 to 45 C, so the instrument should not be left on a sunlit roof; the temperature reading is only specified up to 45 C and is not suited to hot exhaust air.
Accessories mentioned
The handle, optional articulating extension, Air Cone kit, AC adapter, USB cable, carrying case and LogDat2 software are the items named in the manual.
Selection and installation notes
Handheld air and environment meters are selected from the quantity measured, the range and the accuracy needed. Let the probe settle in the air stream, take readings at the points and the number the test method requires, keep the sensors clean, check the battery before a survey and keep the calibration current according to your quality system. Note the conditions and the probe position with every reading so the survey can be repeated.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Frequently asked questions
What is the vane head size? 100 mm (4 in.).
What is the velocity range? 0.25 to 30 m/s (50 to 6,000 ft/min).
Can it calculate air volume? Yes, from velocity and an entered duct area up to 500 ft2 (46.45 m2), or with the Air Cone kit on small outlets.
How accurate is it? +/-1.0 % of reading plus or minus 4 ft/min (0.02 m/s) per Appendix A.
Is Seven Star LLC a TSI distributor? No, Seven Star LLC is independent. We supply TSI instruments from Muscat without any distributor status.
Documents and quotation
Official source document: TSI P/N 1980566 Rev G, November 2024, attached. Seven Star LLC quotes on request; confirm the variant, probes and accessories first.
Datasheets & Documents
- Datasheet TSI VelociCalc Model 5725 Operation and Service Manual (P/N 1980566 Rev G) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
TSI is an American maker of precision measuring instruments for airflow, aerosols, particles and indoor air quality. It was founded in 1961 in Minneapolis by Mike Fingerson as Thermo-Systems Engineering Co. and moved into its own facility in Shoreview, Minnesota, in 1976, where it is still headquartered.
Seven Star LLC is an independent supplier in Muscat. We list TSI instruments for HVAC, cleanroom and environmental users in Oman and the GCC.
TSI company profile
| Founded | 1961, Minneapolis, Minnesota, USA, as Thermo-Systems Engineering Co. |
|---|---|
| Founder | Mike Fingerson |
| Headquarters | Shoreview, Minnesota, since 1976 |
| Early technology | Thermal anemometry for air velocity measurement |
| Product families | VelociCalc air velocity and multi-function meters, DustTrak aerosol monitors, AeroTrak particle counters, PortaCount respirator fit testers, Alnor balometers, Q-Trak indoor air quality monitors |
Milestones
- 1961: Thermo-Systems Engineering is founded in Minneapolis.
- 1976: TSI opens its Shoreview facility.
TSI product series
Ventilation instruments include the VelociCalc 9545 air velocity meter, the VelociCalc 9565 multi-function ventilation meter, the VelociCalc 5725 rotating vane anemometer, the DP-Calc 5825 micromanometer for duct and filter pressure and the AccuBalance 8380 capture hood for measuring airflow at diffusers and grilles.
Air quality and aerosol instruments include the Q-Trak 7575 indoor air quality monitor with plug-in probes, the IAQ-Calc 7525 for CO2, temperature and humidity, the P-Trak 8525 ultrafine particle counter and the DustTrak II 8530 and DustTrak DRX 8533 desktop aerosol monitors for PM1, PM2.5 and PM10.
Where TSI instruments are used
HVAC testing and balancing, cleanroom and laboratory ventilation checks, fume hood testing, indoor air quality surveys and dust monitoring on construction, industrial and plant sites.
TSI products we list
Ordering TSI instruments: what we need
Send the model, the probes and accessories required, the software and calibration certificate needs, and for dust monitors the measurement mode and inlet. We confirm the configuration against the official manual before quoting.
Facts checked against TSI's corporate capabilities statement and company profiles, October 2026.
Browse TSI products by category: Portable Test & Measurement.
Related products
Frequently Asked Questions
100 mm (4 in.).
0.25 to 30 m/s (50 to 6,000 ft/min).
Yes, from velocity and an entered duct area up to 500 ft2 (46.45 m2), or with the Air Cone kit on small outlets.
+/-1.0 % of reading plus or minus 4 ft/min (0.02 m/s) per Appendix A.
No, Seven Star LLC is independent. We supply TSI instruments from Muscat without any distributor status.

Reviews