Brand:

Eaton DILM9-10(230V50HZ,240V60HZ) Contactor 9 A 230 V AC Coil

Description

Eaton DILM9-10(230V50HZ,240V60HZ) contactor, 9 A AC-3, 230 V 50 Hz coil

The Eaton DILM9-10(230V50HZ,240V60HZ) (catalog number 276690) is a three-pole DILM contactor for motors up to 4 kW at 400 V. It is rated 9 A in AC-3, 22 A in AC-1, and it carries one built-in normally open auxiliary contact. The coil is for 230 V at 50 Hz and 240 V at 60 Hz. The housing is the compact FS1 frame, 45 mm wide, which is shared with the 7 A and 12 A versions of the range, so panel layouts can move between ratings without changing the mounting pattern. Seven Star LLC supplies the DILM9-10(230V50HZ,240V60HZ) in Oman and the GCC.

How to read the model code DILM9-10(230V50HZ,240V60HZ)

The prefix DILM names the series, 9 stands for the 9 A AC-3 rating and 10 for one N/O auxiliary contact with no N/C contact. The bracket defines the coil: 230 V for 50 Hz and 240 V for 60 Hz. Next to it in the range, the DILM9-10(230V50HZ,240V60HZ) sits above the 7 A model DILM7-10 and below the 12 A model DILM12-10, which makes it the usual choice for 4 kW motors at 400 V where the next size down would be too small.

DILM9-10(230V50HZ,240V60HZ) technical specifications

Parameter Specification
Manufacturer / part number Eaton DILM9-10(230V50HZ,240V60HZ) (catalog number 276690)
Series Eaton Moeller DILM
Contacts 3 main contacts (N/O), 1 N/O auxiliary contact built in
Coil 230 V 50 Hz / 240 V 60 Hz AC
Pick-up / drop-out voltage 0.8 – 1.1 × Uc / 0.6 – 0.3 × Uc (AC operated)
Rated operational current AC-3, 380/400/415 V 9 A
Rated operational current AC-3, 500 V / 660–690 V 7 A / 5 A
Rated operational power AC-3 at 380/400 V, 50 Hz 4 kW
Rated operational power AC-3 at 240 V / 415 V / 440 V / 500 V / 690 V, 50 Hz 3 kW / 5.5 kW / 5.5 kW / 4.5 kW / 4.5 kW
Rated operational current AC-1, 380–415 V 22 A
Rated breaking capacity at 220–400 V / 500 V / 660–690 V 90 A / 70 A / 50 A
Rated making capacity up to 690 V 112 A
Rated insulation voltage Ui / impulse withstand Uimp 690 V / 8000 V AC
Short-circuit protection, type 1 coordination, 400 V / 690 V 35 A gG/gL / 20 A gG/gL
Short-circuit protection, type 2 coordination, 400 V / 690 V 20 A gG/gL / 16 A gG/gL
Conventional thermal current Ith, 3-pole open at 55 °C / enclosed 21 A / 18 A
Heat dissipation per pole (current dependent) / static coil loss 0.2 W / 1.4 W
Frame size FS1
Ambient temperature, open / enclosed -25 to 60 °C / -25 to 40 °C
Dimensions (depth x height x width) 75 x 68 x 45 mm
Weight 0.24 kg

The values above follow the manufacturer specification sheet for catalog number 276690. The sheet also lists North American ratings and approvals, including UL and CSA, IEC/EN 60947-4-1 and CE marking.

What the DILM9-10(230V50HZ,240V60HZ) can switch

In utilisation category AC-3 the sheet lists 9 A up to 440 V, 7 A at 500 V and 5 A at 660/690 V. The corresponding motor powers are 3 kW at 240 V, 4 kW at 380/400 V, 5.5 kW at 415 V and 440 V, and 4.5 kW at 500 V and 690 V. For heavy starting duty in AC-4 the sheet gives 6 A at 220-240 V and 440 V and 5 A at 500 V.

Rated breaking capacity is 90 A at 220-400 V, 70 A at 500 V and 50 A at 660/690 V, with a making capacity of 112 A.

Selection checklist for the DILM9-10(230V50HZ,240V60HZ)

  • Confirm the motor nameplate current is 9 A or less at the operating voltage, taking the 500 V and 690 V derating into account.
  • Check that the control supply matches the 230 V 50 Hz or 240 V 60 Hz coil.
  • Choose back-up protection: 20 A gG/gL for type 2 coordination and 35 A gG/gL for type 1 at 400 V.
  • Plan an overload relay such as the ZB12 series or a motor protective breaker for the 6 to 10 A band.
  • Allow for the 0.2 W heat loss per pole at 9 A when you calculate the enclosure temperature rise.

Mounting, wiring and service of the DILM9-10(230V50HZ,240V60HZ)

The contactor is 75 mm deep, 68 mm high and 45 mm wide and weighs 0.24 kg. Wire the coil to A1 and A2, tighten the main terminals to 1.2 Nm and strip conductors by 10 mm. Coil power consumption is 24 VA at 50 Hz pick-up and 3.4 VA or 1.4 W sealed, so a small control transformer can feed many contactors at once.

During service, check that the armature closes quietly and that terminal screws stay tight after thermal cycling. If a contactor is replaced, take the full model code including the coil bracket from the old nameplate so the new part matches.

Where the DILM9-10(230V50HZ,240V60HZ) is used in Oman and the GCC

The DILM9-10(230V50HZ,240V60HZ) fits skid-mounted pumps, small fans and compressors, door and gate motors and conveyor drives delivered to oil and gas, water and building sites in Oman. In hot panels in the Gulf the contactor operates at up to 40 °C enclosed and 60 °C open air, which gives a useful margin when enclosures are shaded or air conditioned.

Eaton DILM family overview

Model Typical AC-3 current Typical power at 400 V
DILM7-10 7 A 3 kW
DILM9-10 9 A 4 kW
DILM12-10 12 A 5.5 kW
DILM17-10 18 A 7.5 kW
DILM25-10 / DILMC25-10 25 A 11 kW
DILM32-10 32 A 15 kW

The table shows representative sizes from the same contactor range; the exact coil and terminal version is defined by the model code, so always quote the full text of DILM9-10(230V50HZ,240V60HZ).

Information to send with an RFQ for DILM9-10(230V50HZ,240V60HZ)

  • Exact model DILM9-10(230V50HZ,240V60HZ) (catalog number 276690) and the quantity, including spares.
  • Motor power, voltage and starting method.
  • Coil voltage and frequency available in the panel.
  • Overload relay to be fitted.
  • Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
  • Any documents you need with the quotation, such as an installation leaflet or declaration of conformity.

Documents and quotation

The manufacturer specification sheet for DILM9-10(230V50HZ,240V60HZ) is attached on this page, so you can check the ratings, dimensions and approvals against your project before you order. Installation leaflets and declarations of conformity can be requested separately.

Seven Star LLC supplies Eaton industrial control products in Oman and the GCC. To request a quotation, send model DILM9-10(230V50HZ,240V60HZ), the quantity and your delivery location, and we will confirm availability and lead time for your order.

Other Models in the Eaton Dilm Contactor Range

Seven Star LLC supplies models from the Eaton Dilm Contactor range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Eaton DILM7-10(230V50HZ,240V60HZ) Contactor 7 A 230 V AC CoilContactors & Overload RelaysView details
Eaton DILM9-10(230V50HZ,240V60HZ) Contactor 9 A 230 V AC CoilContactors & Overload RelaysYou are viewing this model
Eaton DILM17-10(24V50/60HZ) Contactor 18 A with 24 V AC CoilContactors & Overload RelaysView details
Eaton DILM17-10(230V50HZ,240V60HZ) Contactor 18 A 230 V ACContactors & Overload RelaysView details
Eaton DILM17-10(380V50/60HZ) Contactor 18 A 380 V AC CoilContactors & Overload RelaysView details
Eaton DILM25-10(230V50/60HZ) Contactor 25 A 230 V AC CoilContactors & Overload RelaysView details
Eaton DILM32-10(230V50HZ,240V60HZ) Contactor 32 A 230 V ACContactors & Overload RelaysView details
Eaton DILMC25-10(230V50HZ,240V60HZ) Contactor 25 A Spring CageContactors & Overload RelaysView details
Datasheets & Documents
  • PDF Datasheet Eaton DILM9-10(230V50HZ,240V60HZ) Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Eaton is a power management company that began in 1911, when Joseph O. Eaton started a truck axle business in New York and moved it to Cleveland, Ohio, in 1914. It grew from vehicle components into electrical equipment, hydraulics and aerospace systems. Since buying Cooper Industries in 2012, Eaton has been incorporated in Ireland with its head office in Dublin, and it is listed on the New York Stock Exchange.

Seven Star LLC lists Eaton NZM molded case circuit breakers, PKZM0 motor-protective circuit breakers and Bussmann series Class J fuses, and supplies them to panel builders and maintenance teams in Oman and the GCC.

Eaton company profile

Founded 1911, New York, USA, by Joseph O. Eaton
Early move Cleveland, Ohio, 1914
Headquarters Dublin, Ireland, since the 2012 Cooper Industries acquisition
Listing New York Stock Exchange (ETN)
Brands Eaton, Moeller, Bussmann, Crouse-Hinds, MTL and MEDC
Product families FAZ and PL miniature circuit breakers, NZM moulded-case breakers, DILM contactors, PowerXL variable frequency drives, 9PX and 93PM UPS, Bussmann fuses, hazardous-area enclosures and signalling

Milestones

  • 1911: Joseph O. Eaton starts an axle business in New York.
  • 1914: The business moves to Cleveland.
  • 2012: Eaton acquires Cooper Industries and redomiciles in Ireland.

Eaton circuit protection listed here

The NZMN1-A80 is a frame size 1 molded case circuit breaker rated 80 A with a thermomagnetic release for cable and system protection. The PKZM0-1,6 is a motor-protective circuit breaker whose overload release is adjustable from 1 to 1.6 A, used as a manual motor starter. The LPJ-35SP is a Bussmann series Low-Peak Class J time-delay fuse rated 35 A at 600 V AC. Older NZM and PKZ devices carry the Moeller name on the nameplate, and the type designations are the same.

Where Eaton breakers and fuses are used

Motor control centers, feeder panels, machine control cabinets and UL-style fused disconnects.

Eaton products we list

Family Examples
Circuit Breakers LPJ-35SP Class J Time-Delay Fuse, NZMN1-A80 Molded Case Circuit Breaker, NZMN2-A250 Molded Case Circuit Breaker, NZMN3-AE400 Molded Case Circuit Breaker, PKZM0-1
AC Drives DA1-342D2FB-A20C AC Drive, PowerXL DG1-34140FN-C21C Variable Freque…

Ordering Eaton parts: what we need

Send the full type and article number, the number of poles, the current rating or setting range, and any accessories such as auxiliary contacts, trip releases or rotary handles.

Facts checked against Eaton's corporate history and investor materials, October 2026.

FAQ

Questions about the Eaton DILM9-10(230V50HZ,240V60HZ) Contactor 9 A 230

Answers from our engineering team on installation, compatibility and integration.

01What is the AC-3 rating of the DILM9-10(230V50HZ,240V60HZ)?
The sheet lists 9 A at 220 to 440 V, 7 A at 500 V and 5 A at 660 to 690 V, equal to 4 kW at 380/400 V.
02Which coil is fitted to the DILM9-10(230V50HZ,240V60HZ)?
A 230 V coil for 50 Hz mains and 240 V for 60 Hz. The coil pulls in at 0.8 to 1.1 times the rated voltage and drops out between 0.6 and 0.3 times.
03How much power does the DILM9-10(230V50HZ,240V60HZ) coil draw?
The sheet gives 24 VA at 50 Hz and 30 VA at 60 Hz while pulling in, and sealed consumption of 3.4 VA or 1.4 W at 50 Hz and 4.4 VA or 1.4 W at 60 Hz.
04What breaking capacity does the DILM9-10(230V50HZ,240V60HZ) have?
Rated breaking capacity is 90 A at 220 to 400 V, 70 A at 500 V and 50 A at 660 to 690 V, with a rated making capacity of 112 A.
05Which fuse is recommended with the DILM9-10(230V50HZ,240V60HZ)?
At 400 V the sheet gives 20 A gG/gL for type 2 coordination and 35 A gG/gL for type 1. At 690 V the values are 16 A and 20 A gG/gL respectively.