Brand: Eaton
Eaton DILM12-10(24VDC) Contactor 12 A with 24 V DC Coil
Description
Eaton DILM12-10(24VDC) contactor, 12 A, 24 V DC coil
The Eaton DILM12-10(24VDC) (catalog number 276845) is the DC-operated version of the DILM12-10 contactor, with a 24 V DC coil. Its power circuit matches the AC versions, three main contacts rated 12 A in AC-3 and one N/O auxiliary contact, but the coil draws 4.5 W from a 24 V DC supply and carries a built-in varistor suppressor circuit. That makes the DILM12-10(24VDC) the natural choice when the contactor is driven by a PLC transistor output or a 24 V DC control supply, as in most modern machine control panels. Seven Star LLC supplies the DILM12-10(24VDC) in Oman and the GCC.
Understanding DILM12-10(24VDC)
DILM12-10 is the base contactor: series DILM, 12 A AC-3 current, one N/O auxiliary contact. The bracket (24VDC) gives the coil, a 24 V DC coil. The sibling DILM12-10(24V50/60HZ) uses a 24 V AC coil and the DILM12-10(230V50/60HZ) a 230 V AC coil. Do not confuse the 24 V AC and 24 V DC versions: they look the same on the rail but their coils are not interchangeable, and the DC version is slightly heavier at 0.296 kg.
DILM12-10(24VDC) technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Eaton DILM12-10(24VDC) (catalog number 276845) |
| Coil voltage Us | 24 V DC |
| Coil power, pick-up / sealing | 4.5 W / 4.5 W |
| Pick-up voltage | 0.8 – 1.1 × Uc (see sheet for conditions) |
| Drop-out voltage | 0.6 – 0.15 × Uc |
| Closing delay (make contacts), max | 31 ms |
| Opening delay (make contacts), max | 12 ms |
| Suppressor circuit | Varistor, fitted |
| Rated making capacity up to 690 V | 168 A |
| Resistance per pole | 4.6 mΩ |
| Heat dissipation, total / per pole | 1.5 W / 0.5 W |
| Static heat dissipation, non-current-dependent | 4.5 W |
| Series | Eaton Moeller DILM |
| Product category | Contactor, 3 main contacts (N/O) plus 1 N/O auxiliary contact |
| Frame size | FS1 |
| Rated operational power AC-3, 240 V / 380/400 V / 415 V, 50 Hz | 4 kW / 5.5 kW / 7 kW |
| Rated operational power AC-3, 440 V / 500 V / 690 V, 50 Hz | 7.5 kW / 7 kW / 6.5 kW |
| Rated operational current AC-3, up to 440 V | 12 A |
| Rated operational current AC-3, 500 V / 660–690 V | 10 A / 7 A |
| Rated operational current AC-1, 380–415 V | 22 A |
| Rated operational current AC-4, 220–240 V and 440 V / 500 V / 660–690 V | 7 A / 6 A / 5 A |
| Conventional thermal current Ith, open at 55 °C / enclosed | 21 A / 18 A |
| Rated insulation voltage Ui | 690 V |
| Rated impulse withstand voltage Uimp | 8000 V AC |
| Rated breaking capacity at 220–400 V / 500 V / 660–690 V | 120 A / 100 A / 70 A |
| Short-circuit protection, type 1 coordination, 400 V / 690 V | 35 A gG/gL / 25 A gG/gL |
| Short-circuit protection, type 2 coordination, 400 V / 690 V | 20 A gG/gL / 20 A gG/gL |
| Degree of protection | IP20, finger and back-of-hand proof |
| Connection | Screw terminals; solid 1 × 0.75–4 mm² or 2 × 0.75–2.5 mm²; flexible with ferrule 1 or 2 × 0.75–2.5 mm² |
| Tightening torque / stripping length | 1.2 Nm / 10 mm |
| Dimensions (depth x height x width) | 75 x 68 x 45 mm |
| Mechanical lifespan | 10,000,000 operations (DC operated) |
| Mechanical operating frequency | 9000 operations per hour |
| Weight | 0.296 kg |
The data follows the manufacturer specification sheet for catalog number 276845. For North American ratings the sheet lists 1 HP at 115/120 V and 2 HP at 230/240 V single-phase, and 3 HP at 200/208 V and 230/240 V, 10 HP at 460/480 V and 10 HP at 575/600 V three-phase at 60 Hz.
How the DILM12-10(24VDC) coil behaves
A DC coil holds the contactor closed with a constant current, which gives silent operation without the hum of an AC magnet. The DILM12-10(24VDC) draws 4.5 W both when pulling in and when holding, so the load on the 24 V supply is about 0.19 A per contactor. When this is added up over a panel with many contactors the PLC output stage or power supply must be sized accordingly: transistor outputs often have a limit of 0.5 A, so one contactor per output is usual.
Because a coil is an inductive load, switching it off produces a voltage spike. The DILM12-10(24VDC) has a varistor suppressor circuit fitted to limit that spike and protect the driving output. Closing takes up to 31 ms and opening up to 12 ms, a little slower than the AC versions. The sheet notes a drop-out voltage of 0.6 to 0.15 times Uc and indicates that the DC supply should be at least a smoothed two-phase bridge rectifier or a three-phase rectifier if it is derived from the mains.
Where the DILM12-10(24VDC) fits
Typical use is a motor starter in a machine panel controlled by a PLC, with the contactor driven from a 24 V DC output. The main contacts carry 12 A in AC-3, 5.5 kW at 380/400 V, with 22 A available in AC-1 for resistive loads. As in the other versions, the contactor is paired with a motor-protective breaker such as the PKZM0-10 or PKZM0-16 for overload and short-circuit protection, and the built-in N/O auxiliary contact can feed back to a PLC input. For control circuits at 230 V AC the DILM12-10(230V50/60HZ) is the matching part.
Selection checklist for the DILM12-10(24VDC)
- Confirm the control voltage is 24 V DC and that the supply can deliver 4.5 W per contactor.
- Check the PLC output rating; use an interposing relay if the output cannot supply the coil current.
- Check the motor current does not exceed 12 A at the operating voltage.
- Verify that the varistor suppression suits the output type; observe polarity as indicated on the coil terminals.
- Decide on short-circuit coordination and protective device.
Installation and maintenance of the DILM12-10(24VDC)
Connect the coil terminals A1 and A2 with the polarity shown on the device and the main contacts as for any DILM12-10. Tighten terminals to 1.2 Nm. Check the 24 V supply under load, because a sagging supply may prevent pick-up. In service, listen for chatter, check terminals for heat marks and verify that the PLC output reaches the coil voltage with all contactors energised.
Typical applications in Oman and the GCC
PLC-controlled skids, packaged pumps and compressor packages supplied to oil and gas, water and industrial sites in Oman and the GCC mostly use 24 V DC control, and the DILM12-10(24VDC) is a typical building block for them. High panel temperatures reduce the margin on coil supply and contact ratings, so keep the enclosure within its rating. Dust and humidity should be managed through sealed enclosures.
Eaton DILM12-10 coil variants
| Model | Catalog number | Coil |
|---|---|---|
| DILM12-10(24V50/60HZ) | 276834 | 24 V, 50/60 Hz AC coil |
| DILM12-10(230V50/60HZ) | 276838 | 230 V, 50/60 Hz AC coil |
| DILM12-10(24VDC) | 276845 | 24 V DC coil, varistor suppressor fitted |
Further coil voltages of the same contactor exist, among them 42 V, 110 V, 220 V, 380 V and 12 V DC; confirm the coil voltage you need against the exact model code.
Information to send with an RFQ for DILM12-10(24VDC)
- Exact model DILM12-10(24VDC) (catalog number 276845) and the quantity, including spares.
- Motor current and voltage, or load type.
- Confirmation of 24 V DC control and the driving PLC output.
- Protective device or overload relay to be combined.
- Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
- Any documents you need with the quotation, such as an installation leaflet or declaration of conformity.
Documents and quotation
The manufacturer specification sheet for DILM12-10(24VDC) is attached on this page, so you can check the ratings, dimensions and approvals against your project before you order. Installation leaflets and declarations of conformity can be requested separately.
Seven Star LLC supplies Eaton industrial control products in Oman and the GCC. To request a quotation, send model DILM12-10(24VDC), the quantity and your delivery location, and we will confirm availability and lead time for your order.
Other Models in the Eaton Dilm12 10 Range
Seven Star LLC supplies models from the Eaton Dilm12 10 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Eaton DILM12-10(24V50/60HZ) Contactor 12 A 24 V AC | Contactors & Overload Relays | View details |
| Eaton DILM12-10(230V50/60HZ) Contactor 12 A 230 V AC | Contactors & Overload Relays | View details |
| Eaton DILM12-10(24VDC) Contactor 12 A with 24 V DC Coil | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Eaton DILM12-10(24VDC) Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Eaton is a power management company that began in 1911, when Joseph O. Eaton started a truck axle business in New York and moved it to Cleveland, Ohio, in 1914. It grew from vehicle components into electrical equipment, hydraulics and aerospace systems. Since buying Cooper Industries in 2012, Eaton has been incorporated in Ireland with its head office in Dublin, and it is listed on the New York Stock Exchange.
Seven Star LLC lists Eaton NZM molded case circuit breakers, PKZM0 motor-protective circuit breakers and Bussmann series Class J fuses, and supplies them to panel builders and maintenance teams in Oman and the GCC.
Eaton company profile
| Founded | 1911, New York, USA, by Joseph O. Eaton |
|---|---|
| Early move | Cleveland, Ohio, 1914 |
| Headquarters | Dublin, Ireland, since the 2012 Cooper Industries acquisition |
| Listing | New York Stock Exchange (ETN) |
| Brands | Eaton, Moeller, Bussmann, Crouse-Hinds, MTL and MEDC |
| Product families | FAZ and PL miniature circuit breakers, NZM moulded-case breakers, DILM contactors, PowerXL variable frequency drives, 9PX and 93PM UPS, Bussmann fuses, hazardous-area enclosures and signalling |
Milestones
- 1911: Joseph O. Eaton starts an axle business in New York.
- 1914: The business moves to Cleveland.
- 2012: Eaton acquires Cooper Industries and redomiciles in Ireland.
Eaton circuit protection listed here
The NZMN1-A80 is a frame size 1 molded case circuit breaker rated 80 A with a thermomagnetic release for cable and system protection. The PKZM0-1,6 is a motor-protective circuit breaker whose overload release is adjustable from 1 to 1.6 A, used as a manual motor starter. The LPJ-35SP is a Bussmann series Low-Peak Class J time-delay fuse rated 35 A at 600 V AC. Older NZM and PKZ devices carry the Moeller name on the nameplate, and the type designations are the same.
Where Eaton breakers and fuses are used
Motor control centers, feeder panels, machine control cabinets and UL-style fused disconnects.
Eaton products we list
Ordering Eaton parts: what we need
Send the full type and article number, the number of poles, the current rating or setting range, and any accessories such as auxiliary contacts, trip releases or rotary handles.
Facts checked against Eaton's corporate history and investor materials, October 2026.
Browse Eaton products by category: Circuit Breaker.
FAQ
Questions about the Eaton DILM12-10(24VDC) Contactor 12 A with 24 V DC
Answers from our engineering team on installation, compatibility and integration.
01What coil does the DILM12-10(24VDC) have?
A 24 V DC coil with a power consumption of 4.5 W at pick-up and 4.5 W when sealed. A varistor suppressor circuit is fitted.
02How fast does the DILM12-10(24VDC) switch?
The sheet lists a maximum closing delay of 31 ms and a maximum opening delay of 12 ms for the make contacts in DC operation.
03What is the rated current of the DILM12-10(24VDC)?
Same power circuit as the AC versions: 12 A in AC-3 up to 440 V, 10 A at 500 V, 7 A at 690 V, and 22 A in AC-1 at 380 to 415 V.
04How much heat does the DILM12-10(24VDC) dissipate?
The sheet gives 1.5 W for the equipment current-dependent loss, 0.5 W per pole, and 4.5 W static non-current-dependent loss from the coil.
05Is the DILM12-10(24VDC) interchangeable with the 24 V AC version?
No. The coils are different. The DC version has a DC coil with varistor and weighs 0.296 kg, while the 24 V AC version weighs 0.24 kg.