Eaton ZB65-10 thermal overload relay, 6 – 10 A

The Eaton ZB65-10 (catalog number 278455) is a three-pole thermal overload relay from the Moeller ZB range with an adjustable setting range of 6 to 10 A. It protects small motors from 6 to 10 A on contactors that take the ZB65 frame against overload and phase failure, and it is designed for direct mounting on suitable DILM contactors. It has class 10 A tripping, one N/O and one N/C auxiliary contact, manual or automatic reset and a test/off button. Seven Star LLC supplies the ZB65-10 in Oman and the GCC.

The ZB65 frame is the larger frame of the ZB family, and the ZB65-10 is its lowest setting range at 6 to 10 A. Use it when a contactor that takes the ZB65 frame is installed but the motor is small, for example in a conveyor or pump starter sized with spare capacity.

How to read the model code ZB65-10

ZB is the series of thermal overload relays, the first number is the frame size (65) and the second number is the upper end of the setting range in amperes, here 10 A. The lower end of the range is given on the sheet as 6 A. The relay is set to the motor nameplate current on the dial; it does not contain a separate part number for coil voltage or terminal type, which makes the model code short and simple.

ZB65-10 technical specifications

Parameter Specification
Manufacturer / part number Eaton ZB65-10 (catalog number 278455)
Series / type Eaton Moeller ZB thermal overload relay, frame ZB65
Current setting range 6 – 10 A
Trip class Class 10 A (IEC 60947-4-1)
Auxiliary contacts 1 N/O + 1 N/C
Reset Manual / automatic, selectable by push-button
Functions Test/off button, trip-free release, phase-failure sensitivity (IEC/EN 60947, VDE 0660 Part 102)
Rated operational voltage Ue / voltage rating, max 690 V / 600 V AC
Rated impulse withstand voltage Uimp 6000 V AC (4000 V for auxiliary and control circuits)
Auxiliary contact rating AC-15: 1.5 A at 120–240 V, 0.9 A at 380–415 V; DC-13: 0.9 A at 24 V, 0.75 A at 60 V, 0.4 A at 110 V, 0.2 A at 220–230 V
Back-up fuse, type 1 coordination (100 kA, 690 V) 50 A gG/gL
Back-up fuse, type 2 coordination (100 kA, 690 V) 25 A gG/gL
Back-up fuse for auxiliary circuit max. 6 A gG/gL
Temperature compensation Continuous, residual error ≤ 0.25 %/K above 40 °C
Ambient temperature, open / enclosed -25 to 55 °C / -25 to 40 °C
Heat dissipation, total / per pole 7.5 W / 2.5 W
Main terminals, flexible with ferrule / stripping length 2 x (1 – 25) mm² / 11 mm
Tightening torque, main terminals 3.5 Nm
Degree of protection / pollution degree IP00 / 3
Mounting Direct mounting on the contactor
Dimensions (depth x height x width) 88 x 75 x 60 mm
Weight 0.22 kg

All data above follows the manufacturer specification sheet for catalog number 278455. The sheet also lists UL and CSA short-circuit ratings and pilot-duty ratings for the auxiliary contacts.

How the ZB65-10 protects the motor

A thermal overload relay measures motor current through bimetal strips heated by the current itself. When the current is above the set value for long enough, the strips bend and release the tripping mechanism, which opens the N/C contact (95-96) in the contactor coil circuit and closes the N/O contact (97-98) for signalling. Class 10 A means that the relay trips within 10 seconds at 7.2 times the set current, the usual requirement for normal starting duty. The phase-failure sensitivity of the ZB65-10 shortens the trip time if one phase is lost, which protects the motor winding from the higher current in the two remaining phases.

Setting and testing the ZB65-10

  • Set the dial to the full-load current on the motor nameplate, not to the contactor rating; the 6 to 10 A range covers motors up to roughly 10 A.
  • Use the test/off button to check the contact action; check the sheet or the leaflet for the exact function of the button.
  • Select manual reset for machines that must not restart unattended and automatic reset for unattended pumping stations where restart is acceptable.

Selection checklist for the ZB65-10

  • Check that the motor nameplate current falls inside 6 to 10 A, ideally in the middle third of the range.
  • Confirm the relay frame ZB65 matches the contactor you intend to use; the mounting is direct, so the pairing must be correct.
  • Use a back-up fuse of 25 A gG/gL for type 2 coordination or 50 A gG/gL for type 1 coordination, as listed on the sheet.
  • Wire the N/C contact into the coil circuit and the N/O contact into an alarm if needed.
  • Check conductor size against the terminal capacity of 2 x (1 to 25) mmmm2 per main terminal.

Installation and maintenance of the ZB65-10

The relay measures 88 x 75 x 60 mm in depth, height and width and weighs 0.22 kg. Slide it onto the terminals of the contactor and tighten the connection screws; use a stripping length of 11 mm on the main cables. The relay should be fitted in an enclosure with ambient temperature up to 40 °C or in open air up to 55 °C. After a trip, find the cause (mechanical overload, voltage imbalance, phase loss or a worn bearing) before resetting. Check the setting dial and terminals at scheduled maintenance, and verify the trip function with the test button.

Applications of the ZB65-10 in Oman and the GCC

In Oman and the Gulf, overload relays protect pumps, fans, compressors and conveyors in oil and gas, water and desalination, power and building services. High ambient temperature is common in panels and outdoor enclosures, so the temperature compensation above 40 °C and the heat dissipation figure of 7.5 W per relay should be considered when you size the panel. Dust and humidity make periodic inspection of terminals worthwhile.

Eaton ZB overload relay family

Model Setting range Frame
ZB12-10 6 – 10 A ZB12
ZB32-24 16 – 24 A ZB32
ZB65-10 6 – 10 A ZB65
ZB65-16 10 – 16 A ZB65
ZB65-24 16 – 24 A ZB65
ZB65-65 50 – 65 A ZB65

The table lists the models covered by sibling pages. Other ranges of the ZB family exist; the exact current range is part of the model name, so quote the full ZB65-10 when you request a price.

Information to send with an RFQ for ZB65-10

  • Exact model ZB65-10 (catalog number 278455) and the quantity, including spares.
  • Motor nameplate current, voltage and starting duty.
  • Contactor model that the relay will be fitted to.
  • Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
  • Any documents you need with the quotation, such as an installation leaflet or declaration of conformity.

Documents and quotation

The manufacturer specification sheet for ZB65-10 is attached on this page, so you can check the ratings, dimensions and approvals against your project before you order. Installation leaflets and declarations of conformity can be requested separately.

Seven Star LLC supplies Eaton industrial control products in Oman and the GCC. To request a quotation, send model ZB65-10, the quantity and your delivery location, and we will confirm availability and lead time for your order.

Other Models in the Eaton Zb Overload Relay Range

Seven Star LLC supplies models from the Eaton Zb Overload Relay range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Eaton ZB12-10 Thermal Overload Relay 6-10 AContactors & Overload RelaysView details
Eaton ZB32-24 Thermal Overload Relay 16-24 AContactors & Overload RelaysView details
Eaton ZB65-10 Thermal Overload Relay 6-10 AContactors & Overload RelaysYou are viewing this model
Eaton ZB65-16 Thermal Overload Relay 10-16 AContactors & Overload RelaysView details
Eaton ZB65-24 Thermal Overload Relay 16-24 AContactors & Overload RelaysView details
Eaton ZB65-65 Thermal Overload Relay 50-65 AContactors & Overload RelaysView details
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Eaton is a power management company that began in 1911, when Joseph O. Eaton started a truck axle business in New York and moved it to Cleveland, Ohio, in 1914. It grew from vehicle components into electrical equipment, hydraulics and aerospace systems. Since buying Cooper Industries in 2012, Eaton has been incorporated in Ireland with its head office in Dublin, and it is listed on the New York Stock Exchange.

Seven Star LLC lists Eaton NZM molded case circuit breakers, PKZM0 motor-protective circuit breakers and Bussmann series Class J fuses, and supplies them to panel builders and maintenance teams in Oman and the GCC.

Eaton company profile

Founded 1911, New York, USA, by Joseph O. Eaton
Early move Cleveland, Ohio, 1914
Headquarters Dublin, Ireland, since the 2012 Cooper Industries acquisition
Listing New York Stock Exchange (ETN)
Brands Eaton, Moeller, Bussmann, Crouse-Hinds, MTL and MEDC
Product families FAZ and PL miniature circuit breakers, NZM moulded-case breakers, DILM contactors, PowerXL variable frequency drives, 9PX and 93PM UPS, Bussmann fuses, hazardous-area enclosures and signalling

Milestones

  • 1911: Joseph O. Eaton starts an axle business in New York.
  • 1914: The business moves to Cleveland.
  • 2012: Eaton acquires Cooper Industries and redomiciles in Ireland.

Eaton circuit protection listed here

The NZMN1-A80 is a frame size 1 molded case circuit breaker rated 80 A with a thermomagnetic release for cable and system protection. The PKZM0-1,6 is a motor-protective circuit breaker whose overload release is adjustable from 1 to 1.6 A, used as a manual motor starter. The LPJ-35SP is a Bussmann series Low-Peak Class J time-delay fuse rated 35 A at 600 V AC. Older NZM and PKZ devices carry the Moeller name on the nameplate, and the type designations are the same.

Where Eaton breakers and fuses are used

Motor control centers, feeder panels, machine control cabinets and UL-style fused disconnects.

Eaton products we list

Family Examples
Circuit Breakers LPJ-35SP Class J Time-Delay Fuse, NZMN1-A80 Molded Case Circuit Breaker, NZMN2-A250 Molded Case Circuit Breaker, NZMN3-AE400 Molded Case Circuit Breaker, PKZM0-1
AC Drives DA1-342D2FB-A20C AC Drive, PowerXL DG1-34140FN-C21C Variable Freque…

Ordering Eaton parts: what we need

Send the full type and article number, the number of poles, the current rating or setting range, and any accessories such as auxiliary contacts, trip releases or rotary handles.

Facts checked against Eaton's corporate history and investor materials, October 2026.

FAQ

Questions about the Eaton ZB65-10 Thermal Overload Relay 6-10 A

Answers from our engineering team on installation, compatibility and integration.

01What is the setting range of the ZB65-10?
The relay is adjustable from 6 A to 10 A. Set it to the motor full-load current from the nameplate.
02What trip class does the ZB65-10 have?
It has trip class 10 A according to IEC 60947-4-1, with phase-failure sensitivity per IEC/EN 60947 and VDE 0660 Part 102.
03What auxiliary contacts does the ZB65-10 have?
One N/O and one N/C contact. The N/C contact is normally used in the contactor coil circuit and the N/O contact for an alarm signal.
04Which fuse protects the ZB65-10?
The sheet gives 50 A gG/gL for type 1 coordination and 25 A gG/gL for type 2 coordination, valid at 100 kA and 690 V.
05How large is the ZB65-10?
The sheet gives dimensions of 88 x 75 x 60 mm (depth x height x width) and a weight of 0.22 kg.