- Automation & ControlView all 3,046 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Bürkert
Bürkert 136881 Type 5470 4/2-Way Valve G1/8 Threaded
Description
Overview
Bürkert 136881 is the threaded sibling of the 4/2-way servo-controlled valves in the Bürkert Type 5470 range. Working ports 2 and 4 are G⅛ internal threads on the side of the module, so rigid fittings, push-in connectors with threaded stems or throttle check valves can be screwed in directly. The coil is 24 V DC/UC with 2 W effective power and the valve belongs to circuit function G. Seven Star LLC is an independent supplier serving Oman and the GCC.
Why threaded ports matter on Bürkert 136881
Threaded working ports allow choice of fitting and make the connection more robust under vibration than a hose connector. Fitting a push-in elbow of the correct thread size gives a tidy tube route, while metal fittings suit hot cabinets. The G⅛ thread is a parallel pipe thread, so use a sealing washer or sealant approved for polyamide, and tighten carefully to avoid cracking the body.
Key data of Bürkert 136881
| Parameter | Value |
|---|---|
| Circuit function | G: 4/2-way, servo-controlled |
| Voltage and power | 24 V DC/UC, 2 W effective coil power |
| Working ports 2 and 4 | G 1/8 lateral thread (variant E) |
| Pressure range | 2 to 10 bar overpressure |
| Orifice | 4.0 mm |
| Flow QNn, air | 300 l/min |
| Body and seal | Polyamide body, NBR seal, Ultramid inner parts |
| Weight | about 120 g |
| Medium | Compressed air and neutral gases, 5 micron filtration |
| Medium temperature | minus 10 to plus 50 degrees C |
| Ambient temperature | minus 10 to plus 55 degrees C |
| Switching time DC | Open 15 ms, close 12 ms |
| Duty cycle | 100 percent |
| Voltage tolerance | plus or minus 10 percent |
| Electrical | Plug contacts form C, DIN EN 175301-803, for cable plug Type 2516 |
| Protection | IP65 with cable plug Type 2516 |
Where Bürkert 136881 sits in the 5470 chart
Variant E in the ordering table means the lateral G⅛ thread. Variant B adds a throttle check valve to the same thread, and variants C and F use 6 mm plug-in couplings. 136881 is therefore the plain threaded option. It shares circuit function, orifice, flow and coil with 136878, so a machine builder can swap between hose and thread versions without changing the electrical design.
Typical machine and plant uses
This valve suits small double-acting cylinders and grippers where cylinders have threaded G⅛ ports, mini rotary actuators, and test benches in workshops. In petrochemical and utility plants it can reverse small instrument actuators and dampers, where compact size and low power are the main advantages.
Manifold and module flange practice
The module flange carries supply channels 1 and 3 through the whole valve row, so one compressed air connection and one exhaust connection serve every valve. Valves are added by extending the flange row, and each valve can be exchanged with two screws without disconnecting the tubes of its neighbours. Plan spare flange capacity during design, as adding a station later means shutting down and depressurising the whole row. Label each working port with the valve article number so that maintenance crews can reorder correctly.
Choosing between servo and direct-acting pneumatic valves
This valve is servo-controlled: the coil operates a small pilot that uses the supply pressure to move the main spool or seat. That is how a 2 W coil can pass 300 l/min, but the price is the minimum pressure of 2 bar quoted in the data sheet. If the application involves very low or fluctuating pressure, a direct-acting valve with a larger coil is the safer choice. For most plant air at 6 bar the servo design is efficient and quick, with 15 ms opening and 12 ms closing times on DC supply.
Thermal layout inside control cabinets
Even a 2 W coil adds heat, and a row of twenty valves can release 40 W into a small enclosure. In Gulf conditions where cabinets sit in direct sun, plan ventilation or an air conditioner, keep valves away from drives and power supplies, and respect the ambient limit of 55 degrees C. Mount the valve row where cooling air passes, and avoid sealing the exhaust silencers in a way that allows moisture to enter the flange.
Fault finding on small solenoid valves
If a valve does not switch, measure the voltage at the plug under load, since a long cable can drop several volts. Check the coil for continuity, listen for the click of the pilot, and confirm that the supply pressure is at least 2 bar. If the valve switches but leaks to exhaust, dirt or oil carry-over has probably lodged under the seat, and replacement is the practical remedy. A slow stroke on the cylinder often has nothing to do with the valve: look at tube length, exhaust throttles and silencers clogged with dust, which are common in desert sites.
Setting and checks after installation
Screw in the fittings first, then mount the valve on its module flange. Pressurise gently from 2 bar upward and test for leaks with a suitable solution. Observe the stroke time of the cylinder and adjust exhaust throttles until movement is smooth and quiet. Keep a log of cycles on heavily used machines to schedule valve replacement before failure.
Thread and fitting details for Bürkert 136881
Each G⅛ port takes fittings with a parallel thread and a flat sealing face or an O-ring washer. Avoid conical sealing tape on the polyamide body, because over-tightening can split the housing. When in doubt, tighten by hand and add a quarter turn. Many installers choose push-in fittings with a threaded stem for 6 mm tube, and others choose throttle check valves screwed directly into the port, giving speed control at the cylinder without an extra block.
If the cylinders to be driven already have G⅛ ports, the short link between valve and cylinder cuts tube volume and gives crisp response, and mounting the valve row near the cylinders reduces the exhaust noise carried by long tubes.
Typical quantities and project planning for Bürkert 136881
Machine builders usually order these valves in multiples that match the number of stations on a manifold, plus one or two spare units. For a plant retrofit, count each double-acting cylinder as one valve and add the cable plugs, silencers and blanking plates for unused stations. Ask for a quotation early when the programme is tight, since several weeks can pass between order and delivery for imported pneumatic components.
Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | Festo VZXF-L-M22C-M-A-G12-120-H3B1-50-16 Valve | All Bürkert products.
Documents and quotation
The Type 5470 data sheet that contains Bürkert 136881 is attached, with dimension drawings and ordering tables. Please send your RFQ with part number 136881, quantity and delivery location in Oman or the GCC.
Other Models in the 5470 Range
Seven Star LLC supplies models from the 5470 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Bürkert 136872 Type 5470 3/2-Way Servo Solenoid Valve NC | Solenoid Valves | View details |
| Bürkert 136875 Type 5470 3/2-Way NO Solenoid Valve | Solenoid Valves | View details |
| Bürkert 136878 Type 5470 4/2-Way Servo Solenoid Valve | Solenoid Valves | View details |
| Bürkert 136881 Type 5470 4/2-Way Valve G1/8 Threaded | Solenoid Valves | You are viewing this model |
Datasheets & Documents
- Datasheet Bürkert 136881 Type 5470 4/2-Way Valve G1/8 Threaded Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.
Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.
Bürkert company profile
| Founded | 1946, by Christian Bürkert |
|---|---|
| Headquarters | Ingelfingen, Germany |
| Ownership | Family-owned |
| Product families | Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers |
Bürkert types listed on this page
Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.
Ordering Bürkert valves: what we need
The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.
Facts checked against Bürkert's published company history, October 2026.
Browse Bürkert products by category: Solenoid Valve, Control Valves.
FAQ
Questions about the Bürkert 136881 Type 5470 4/2-Way Valve G1/8 Threaded
Answers from our engineering team on installation, compatibility and integration.
01What thread do the ports of Bürkert 136881 have?
The working ports 2 and 4 are lateral G 1/8 internal threads, listed as variant E in the Type 5470 ordering chart.
02Is 136881 a 4/2-way valve?
Yes, it is circuit function G, a servo-controlled 4/2-way solenoid valve suited to double-acting cylinders.
03What coil does Bürkert 136881 have?
It has a 24 V DC/UC coil with an effective coil power of 2 W, and the voltage tolerance is plus or minus 10 percent.
04What pressure range applies to 136881?
The family is rated for 2 to 10 bar overpressure with compressed air or neutral gases filtered to 5 micron.
05What body material does 136881 use?
The body is polyamide with Ultramid inner parts and an NBR seal, which keeps the weight at approximately 120 g.


















Reviews