Brand: Festo
Festo VZXF-L-M22C-M-A-G12-120-H3B1-50-16 Valve
Description
VZXF-L-M22C-M-A-G12-120-H3B1-50-16: a brass angle seat valve for gaseous media
The Festo VZXF-L-M22C-M-A-G12-120-H3B1-50-16 is a process valve of the angle seat type: a poppet is lifted from its seat by a piston drive, and the pipe turns through an angle inside the body. Order number 1002500. It is closed in its home position, held shut by a mechanical spring, and it is opened by pilot air on the G1/8 drive connection. Since it is externally actuated, a separate control valve is needed to supply the pilot air, and that is where many installations place a small solenoid valve.
Compared with a direct-acting solenoid valve, the angle seat design handles much larger flows: with a 12 mm nominal size and a Kv of 3.5 m3/h, it passes far more than a 2 mm solenoid valve.
Datasheet figures for VZXF-L-M22C-M-A-G12-120-H3B1-50-16
| Parameter | Value |
|---|---|
| Part number | 1002500 |
| Product type | Angle seat valve |
| Design | Poppet valve with piston drive |
| Valve function | 2/2-way, closed, mechanical spring reset |
| Type of actuation | Pneumatic, externally actuated |
| Line connection | Female thread G1/2 (DIN ISO 228) |
| Nominal size | 12 mm |
| Flow rate Kv | 3.5 m3/h |
| Nominal pressure PN | 16 |
| Medium pressure | 0 to 1.6 MPa (0 to 16 bar) |
| Operating (control) pressure | 0.6 to 1 MPa (6 to 10 bar) |
| Drive pneumatic connection | Female thread G1/8 |
| Media | Vapour, inert gases, filtered compressed air (200 micrometre filtration) |
| Flow direction | Above valve seat, for gaseous media |
| Max. viscosity | 600 mm2/s |
| Media temperature | -10 to 80 degrees C |
| Ambient temperature | -10 to 60 degrees C |
| Process valve housing | Red brass CC499K |
| Seat seal | PTFE |
| Spindle seal | NBR |
| Drive housing | Brass |
| Mounting | Inline, any position |
| Exhaust function | Cannot be throttled |
| Corrosion class CRC | 1 |
| Weight | 1200 g |
Medium and direction of flow
The data sheet names vapour, inert gases and filtered compressed air (filtration grade 200 micrometres) as the media, with the flow direction above the valve seat, for gaseous media. That detail matters: in angle seat valves the direction of flow decides how the pressure acts on the poppet, and a reversed connection changes the load on the seat and may reduce sealing. Follow the arrow on the body. The maximum medium pressure is 16 bar, equal to the nominal pressure rating PN16, and the maximum viscosity is 600 mm2/s.
The media temperature range of -10 to 80 degrees C is the figure stated for this valve in the data sheet; check it against your process before selecting VZXF-L-M22C-M-A-G12-120-H3B1-50-16.
What differs from other VZXF angle seat valves
The VZXF series appears in the catalogue index with several thread sizes such as G1/2, G1 1/4 and G2, with NPT versions, and with different drive codes such as H3B1 and M1-V4V4T. The final number of the type code of this version, 16, agrees with the 16 bar nominal pressure, while sibling codes end with other numbers. Compare thread, drive and pressure on the data sheet of the sibling itself. VZXF-L-M22C-M-A-G12-120-H3B1-50-16 combines a brass body with a PTFE seat seal and an NBR spindle seal.
Applications
- Shut-off of compressed air or nitrogen headers in plants and workshops.
- Isolating gas lines where the medium and temperature match the data sheet.
- Process skids for water treatment and food production in the Gulf, where inert gas or air is switched in larger bores.
Because corrosion class CRC 1 applies, protect the valve from salt-laden outdoor air with a cabinet or a coating.
Pilot control of VZXF-L-M22C-M-A-G12-120-H3B1-50-16
Because the valve is externally actuated, the control concept is simple but needs planning. A small 3/2-way solenoid valve supplies pilot air at 6 to 10 bar to the G1/8 connection; when the solenoid is switched off, the drive is exhausted and the spring closes the poppet. This makes the valve fail closed on loss of electrical power or pilot air, a behaviour often demanded in safety concepts for gas isolation. The closing time depends on the length of the pilot tubing and on the exhaust capacity of the control valve, so keep the tubing short and use a control valve with a sufficient flow rate. The data sheet does not list switching times for this valve, so do not assume values; measure them on the actual installation if sequencing is critical.
Compare the supply: the control pressure must be at least 6 bar, so if the plant air drops below that, the valve may not open fully and the flow will fall short of the quoted Kv value. Use a pressure switch on the pilot line if a loss of control air should raise an alarm. For VZXF-L-M22C-M-A-G12-120-H3B1-50-16, a filter in the pilot line keeps the small drive free from particles.
Piping and pilot air connection
Screw the valve inline into G1/2 pipework with a suitable sealant; do not exceed the manufacturer torque on the female thread. Supply 6 to 10 bar of pilot air to the G1/8 drive connection through a filter. The exhaust of the drive cannot be throttled, so slow opening is not available through the exhaust and a throttle should be placed in the supply line instead. Mount the valve in any position; the drive can be upright or sideways.
Maintenance
The wearing parts are the PTFE seat seal and the NBR spindle seal. A leaking valve is usually caused by dirt on the seat, so filter the medium. When replacing VZXF-L-M22C-M-A-G12-120-H3B1-50-16, note the nominal size, thread and pressure part of the type code, as an angle seat valve with a different drive can have another pilot pressure range. Record the number 1002500 for later orders.
Documents and quotation
The PDF data sheet for VZXF-L-M22C-M-A-G12-120-H3B1-50-16 is attached. To request a quotation, send an RFQ with the part number VZXF-L-M22C-M-A-G12-120-H3B1-50-16 and the quantity. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Datasheets & Documents
- Datasheet Festo VZXF-L-M22C-M-A-G12-120-H3B1-50-16 Valve Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Festo is a German maker of pneumatic and electric automation technology, founded in 1925 in Esslingen am Neckar by Albert Fezer and Gottlieb Stoll; the name comes from their surnames. It first made woodworking machines and power tools before moving into pneumatics in the 1950s. Festo is family-owned and still headquartered in Esslingen.
Seven Star LLC sources and supplies Festo cylinders, valves and valve terminals for machine maintenance and projects in Oman and the GCC.
Festo company profile
| Founded | 1925, Esslingen am Neckar, Germany |
|---|---|
| Founders | Albert Fezer and Gottlieb Stoll |
| Name | From FEzer and STOll |
| Headquarters | Esslingen am Neckar |
| Ownership | Family-owned |
| Product families | DSBC and ADN pneumatic cylinders, VUVG and VTUG solenoid valves and valve terminals, MS series air preparation units, CPX-AP remote I/O, EMMT servo motors and CMMT servo drives, electric axes and grippers |
Milestones
- 1925: Fezer and Stoll found the company in Esslingen.
- 1950s: Festo begins making pneumatic components.
Festo products listed
Two items show the two halves of a pneumatic circuit. The VTUG is a valve terminal: a manifold that carries a row of directional valves with common air supply and a shared electrical connection. The DSBC-32-100-PPVA-N3 is an ISO standard cylinder. Its type code reads as 32 mm piston diameter and 100 mm stroke, with adjustable end-position cushioning and a piston magnet for position sensing.
Festo products we list
Ordering Festo parts: what we need
Festo parts carry both a type code and a numeric part number on the label. Send both when you can; the part number is the shortest route to an exact match. For a cylinder give the full type code as on the listed DSBC example, plus mounting parts and proximity switches if required. For a VTUG valve terminal send the configuration code or a label photo: number of valve positions, valve functions, coil voltage and the electrical connection type all vary from one terminal to the next.
Facts checked against Festo's corporate history pages, October 2026.
Browse Festo products by category: Solenoid Valve, Valve Actuator.
FAQ
Questions about the Festo VZXF-L-M22C-M-A-G12-120-H3B1-50-16 Valve
Answers from our engineering team on installation, compatibility and integration.
01What type of valve is Festo VZXF-L-M22C-M-A-G12-120-H3B1-50-16?
It is a pneumatically actuated angle seat valve, a poppet valve with piston drive, 2/2-way and closed by a mechanical spring.
02What media can VZXF-L-M22C-M-A-G12-120-H3B1-50-16 switch?
The data sheet lists vapour, inert gases and filtered compressed air with 200 micrometre filtration, flowing above the seat for gaseous media.
03What are the connections of VZXF-L-M22C-M-A-G12-120-H3B1-50-16?
The line connection is a G1/2 female thread to DIN ISO 228 and the pilot air connection is a G1/8 female thread.
04What pressure does VZXF-L-M22C-M-A-G12-120-H3B1-50-16 need to open?
The operating pilot pressure is 0.6 to 1 MPa, equal to 6 to 10 bar, while the medium pressure is 0 to 16 bar.
05What materials are used in VZXF-L-M22C-M-A-G12-120-H3B1-50-16?
The process housing is red brass CC499K, the seat seal is PTFE, the spindle seal is NBR and the drive housing is brass.