Brand:

Autonics MT4W-DV-4N 4-Digit DC Voltage Panel Meter

Description

Overview

Reading a DC voltage on a panel should not need a pile of ranges and parts, and the Autonics MT4W-DV-4N keeps it simple. It is a 96 x 48 mm four-digit panel meter for DC voltage with selectable ranges from 50 mV up to 500 V, a bright red display with 14.2 mm characters, a 100 to 240 V AC supply and no outputs, which makes it a pure indicator. It can also display scaled engineering units, so a 0 to 10 V signal from a transmitter can read as pressure, flow or level. Seven Star LLC is an independent supplier serving Oman and the GCC.

Decoding Autonics MT4W-DV-4N

MT4W is the 4-digit multi panel meter in the W size. DV is the DC voltage input type, whereas DA is DC current, AV is AC voltage and AA is AC current. The digit 4 is the supply, 100 to 240 V AC at 50/60 Hz, and the letter N states that there is no preset output and no sub output, in other words an indicator. Other letters in that place add relay, NPN or PNP open collector preset outputs, BCD dynamic, 4 to 20 mA transmission, low speed serial or RS485 outputs.

Specifications for Autonics MT4W-DV-4N

Item Data
Input DC voltage, terminals for 250 mV or 50 mV, 5 V or 1 V, 50 V or 10 V, 500 V or 100 V
Allowable input minus 5 to 110 percent of full scale of each range
Display 7-segment red LED, 14.2 mm characters, 4 digits
Display range minus 1999 to 9999
Accuracy 0.1 percent F.S. plus or minus 2 digit at 23 degrees C plus or minus 5; 0.5 percent F.S. plus or minus 3 digit from minus 10 to plus 50 degrees C
Conversion Sigma-delta ADC, sampling cycle 50 ms for DC
Supply 100 to 240 V AC 50/60 Hz, 5 VA
Dielectric strength 3,000 V AC for 1 minute
Noise immunity 2 kV square wave
Vibration and shock 0.75 mm, 10 to 55 Hz, 2 hours; 300 m/s2
Ambient minus 10 to plus 50 degrees C
Protection IP56 front
Weight about 211 g, about 326 g packaged

How the Autonics MT4W-DV-4N differs from other MT4W variants

All MT4W models share the display, size and sampling electronics, and the variation lies in the input and the outputs. The MT4W-DA codes measure DC current from 2 mA up to 5 A, the AV and AA codes measure AC voltage and current with a 16.6 ms sampling cycle and a choice of true RMS or average RMS, and they can also display frequency. The suffix digits after the supply choose a relay, an open collector, a 4 to 20 mA transmission, BCD dynamic, low speed serial or RS485 output. The Autonics MT4W-DV-4N has none of those, so it cannot switch a load or send a signal; it only displays, which is why it is the lowest-cost DC voltage choice and has the least wiring.

Ranges, scaling and zero

The terminals offer two ranges per connection pair, for example 5 V or 1 V on one terminal and 50 V or 10 V on another, and the active range is chosen in a parameter. Within a range the display can be scaled: the manual describes high-limit and low-limit scale values, decimal point positions and a deviation correction, so that 1 V can read as 15.000 or a 4 to 20 mA signal can read 0 to 100 percent. The manual warns that when the maximum input is below 30 percent of the terminal range, display accuracy degrades, so choose the smallest range that fits. A zero adjustment can be carried out from the keys or through the HOLD/ZERO terminal, and the HOLD function freezes the reading for recording.

Applications in Oman and the GCC

Panel voltmeters read battery bank and charger voltage in substations and solar installations, supply voltages in control cabinets, and process signals such as 0 to 10 V from transmitters. In water and gas plants they are used as local indicators of analog signals, and in workshops as test-bench displays. The IP56 front is suited to indoor panels with some dust and splashing, in ambient temperatures up to 50 degrees C.

Installation

Cut the panel as shown in the manual’s dimension drawing, insert the meter from the front and fix with the bracket. Connect the AC supply to the source terminals and the measured signal between the common terminal and the terminal for the chosen range. Keep input wiring away from power cables and use shielded cable for low-level signals such as 50 mV, and be careful never to exceed the input limit of 110 percent of the range. When measuring above the voltage of the supply circuits, take care over insulation clearances.

Display behaviour and errors

If the input exceeds the scale setting or the maximum display of 9999, the display flashes an over-range message, and a corresponding under-range message appears below the minimum of minus 1999. The messages clear automatically when the input returns into range. A flashing zero warning appears when the input exceeds the zero range. These messages are useful during commissioning because they show immediately if the wrong range terminal is wired.

Maintenance

Keep the front clean with a dry cloth, check the terminal screws after a few weeks of service, and verify accuracy against a calibrated source at the intervals your quality system requires, and record the range terminal and scale values used on each installation so a replacement can be set identically within minutes. Because the meter has no relays, wear is limited to the display and electronics, and the insulation and noise ratings of the mains model are higher than those of the 12 to 24 V DC powered type.

Related items you may also need: Autonics E40S6-2500-6-L-5 Rotary Encoder Incremental | SICK WTB27-3P2411 Background Suppression Sensor | SICK GL10-P4211 G10 Retro-Reflective Photoelectric Sensor | All Autonics products.

Documents and quotation

The MT4W series product manual covering the Autonics MT4W-DV-4N is attached with its ordering table, range tables, wiring and dimensions. Send an RFQ with the part number Autonics MT4W-DV-4N, quantity and delivery location in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet Autonics MT4W-DV-4N 4-Digit DC Voltage Panel Meter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Autonics is a South Korean maker of sensors and controllers, founded in 1977 as a small engineering business making controllers for looms. It took the Autonics name in 1988 and opened a new corporate headquarters in Busan in 2014. Autonics makes proximity and photoelectric sensors, rotary encoders, temperature controllers, counters, timers and stepper motor systems, with factories in Busan and Yangsan.

Seven Star LLC lists the Autonics E40S6-2500-6-L-5 incremental rotary encoder and supplies Autonics sensors and control devices in Oman and the GCC.

Autonics company profile

Founded 1977, South Korea
Current name Autonics, since 1988
Headquarters Busan, South Korea
Factories Busan and Yangsan
Product families E40 and E50 rotary encoders, PR proximity sensors, BJ photoelectric sensors, TK temperature controllers

Milestones

  • 1977: The company is founded.
  • 1988: Renamed Autonics Corporation.
  • 2014: Opens its Busan headquarters.

Reading the Autonics E40S encoder code

E40S is the 40 mm diameter shaft-type incremental encoder, and the 6 that follows is the 6 mm shaft. 2500 is the resolution in pulses per revolution. The next 6 means six output signals: A, B and Z with their inverted signals. L is a line driver output and the final 5 is a 5 V DC supply. The same 40 mm body is made in hollow shaft form as the E40H and E40HB series.

Where Autonics encoders are used

Servo and spindle feedback, conveyor length measurement, packaging and printing machines.

Ordering Autonics encoders: what we need

Send the complete model string from the label. If it is worn off, give the body and shaft diameter, pulses per revolution, output type, supply voltage and cable or connector style.

Facts checked against Autonics corporate profiles, October 2026.

FAQ

Questions about the Autonics MT4W-DV-4N 4-Digit DC Voltage Panel Meter

Answers from our engineering team on installation, compatibility and integration.

01What does the N mean in Autonics MT4W-DV-4N?
N means no preset output and no sub output, so the meter is a pure indicator without relay, open collector, transmission or communication outputs.
02What input does the Autonics MT4W-DV-4N measure?
DC voltage on selectable ranges of 50 mV, 250 mV, 1 V, 5 V, 10 V, 50 V, 100 V and 500 V, via separate terminals.
03What supply does the Autonics MT4W-DV-4N need?
The digit 4 means 100 to 240 V AC at 50/60 Hz with a consumption of 5 VA.
04How accurate is the Autonics MT4W-DV-4N?
At 23 degrees C plus or minus 5 it is 0.1 percent of full scale plus or minus 2 digits, and 0.5 percent plus or minus 3 digits from minus 10 to plus 50 degrees C.
05Can the Autonics MT4W-DV-4N show scaled values?