Autonics LE4S 48×48 LCD Digital Timer Multi-Function
Description
Overview
Few timers combine as many functions in a 48 x 48 mm case as the Autonics LE4S. It is a digital multi-time, multi-operation timer with a backlit LCD that shows elapsed time and the set time at once, a relay output with a time limit change-over contact, and a supply that accepts anything from 24 to 240 V, AC or DC. One unit can be set as an ON-delay, interval, OFF-delay, flicker, integrating or ON-OFF delay timer, which makes it a very good single stock item for maintenance departments. Seven Star LLC is an independent supplier serving Oman and the GCC.
What the type name Autonics LE4S means
LE4S is the base model, with no suffix. In the ordering code, an empty mark after LE4S indicates the time limit SPDT (1c) output, whereas an A suffix gives the LE4SA with time limit 2c or time limit 1c plus instantaneous 1c. The base model is the one that supports a selectable minimum input signal width of 1 or 20 ms and a start by signal, while the LE4SA is power ON start.
Technical data of Autonics LE4S
| Item | Data |
|---|---|
| Front size | 48 x 48 mm DIN |
| Display | LCD with backlight, elapsed time and set time shown together |
| Supply | 24 to 240 V AC 50/60 Hz, 24 to 240 V DC |
| Consumption | AC 4.5 VA or less; DC 2 W or less |
| Control output | Time limit SPDT (1c) relay, 250 V AC 5 A, 30 V DC 5 A resistive |
| Inputs | START, INHIBIT, RESET; no-voltage; minimum signal width 1 ms or 20 ms |
| Time start | Signal ON start |
| Return time | 100 ms or less |
| Time ranges | 0.001 s to 9.999 s, 0.01 to 99.99 s, 0.1 to 999.9 s, 1 to 9999 s, 0m1s to 99m59s, 0.1 to 999.9 min, 1 to 9999 min and hour ranges |
| Time direction | UP or DOWN |
| One-shot output time | 0.01 to 99.99 s |
| Relay life | 10 million mechanical, 100,000 electrical operations |
| Dielectric strength | 3,000 V AC for 1 minute |
| Noise immunity | 2 kV square wave |
| Ambient | minus 10 to plus 55 degrees C, 35 to 85 percent RH |
| Weight | about 98 g |
How the Autonics LE4S differs from other LE4S variants
Only one sibling exists in this family, the LE4SA, and the differences are concrete. The LE4SA offers two time limit change-over contacts, or one time limit contact plus one instantaneous contact, with a 3 A rating at 250 V AC, instead of the single 5 A contact of the base model. It adds star-delta and twin operation modes for motor starting and alternating pump duty, but it starts timing on power-on and has no start-signal input of the kind described for the base model. Its power consumption is slightly lower, at 4 VA on AC and 1.6 W on DC. Choose the Autonics LE4S where an external start signal and a 5 A contact are needed.
Operation modes in practice
The manual groups the modes. In group one are the delay and interval functions: ON delay (OND, OND.1, OND.2), interval (INT), OFF delay (OFD) and integration time (INTG). Group two holds flicker (FLK, FLK.1) and ON-OFF delay (NFD, NFD.1), where on and off times are set separately. Group three, with star-delta and twin modes, is for the LE4SA. A time that is progressing is shown by a flashing unit, and the current mode and the state of the output contact are displayed on the LCD, so a technician can diagnose a circuit without a manual.
Setting the time
From run mode, press the left key to enter the time setting mode, the last digit flashes, use the keys to shift digits and change the value, and press MD to finish. The manual warns that time keeps progressing while the setting is edited and that, if no key is pressed for 60 seconds, the unit returns to run mode without storing the new value. After any parameter change, all outputs go off and the current values reset. Eight time units and ranges from 1 millisecond to thousands of minutes give wide coverage, and the one-shot output time of 0.01 to 99.99 seconds helps with pulse outputs.
Where it is used in Oman and the GCC
A timer with a universal supply is popular in pump control, ventilation, lighting, dosing and conveyor systems. For example, an ON delay lets a compressor build pressure before loading, an OFF delay keeps a cooling fan running after a motor stops, and a flicker mode drives a beacon. The supply up to 240 V DC covers legacy 110 V DC control circuits in power plants as well as 230 V AC and 24 V panels, which simplifies spares.
Wiring cautions
The power and signal input terminals are not isolated from each other, so take care when connecting sensors and contacts. A no-voltage input is operated by a transistor or a contact, and a contact input requires a contact that can switch 5 V DC at 1 mA. Do not run input wires beside power cables; use shielded cable where noise is likely. Use a switch for power on and off to avoid chattering, and install a breaker within reach.
Maintenance
Wipe with a dry cloth only. The backlight can be turned off with a parameter, and the key lock prevents accidental changes. With a relay life of 100,000 electrical operations at rated load, a high-cycle application should switch a contactor and not a large load directly. Keep the unit away from metal chips and dust. When replacing a failed timer, copy the output operation mode, time range, UP or DOWN direction and the minimum input width to the new unit, and note them on the panel drawing for the next engineer who visits the cabinet.
Related items you may also need: Autonics E40S6-2500-6-L-5 Rotary Encoder Incremental | SICK WTB12-3P2461S58 Proximity Sensor | Omron E3Z-D61 Photoelectric Sensor 100 mm diffuse | All Autonics products.
Documents and quotation
The LE4S series product manual covering the Autonics LE4S is attached with ordering information, mode charts, wiring and dimensions. Send an RFQ with the part number Autonics LE4S, quantity and delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Autonics LE4S 48x48 LCD Digital Timer Multi-Function Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Autonics is a South Korean maker of sensors and controllers, founded in 1977 as a small engineering business making controllers for looms. It took the Autonics name in 1988 and opened a new corporate headquarters in Busan in 2014. Autonics makes proximity and photoelectric sensors, rotary encoders, temperature controllers, counters, timers and stepper motor systems, with factories in Busan and Yangsan.
Seven Star LLC lists the Autonics E40S6-2500-6-L-5 incremental rotary encoder and supplies Autonics sensors and control devices in Oman and the GCC.
Autonics company profile
| Founded | 1977, South Korea |
|---|---|
| Current name | Autonics, since 1988 |
| Headquarters | Busan, South Korea |
| Factories | Busan and Yangsan |
| Product families | E40 and E50 rotary encoders, PR proximity sensors, BJ photoelectric sensors, TK temperature controllers |
Milestones
- 1977: The company is founded.
- 1988: Renamed Autonics Corporation.
- 2014: Opens its Busan headquarters.
Reading the Autonics E40S encoder code
E40S is the 40 mm diameter shaft-type incremental encoder, and the 6 that follows is the 6 mm shaft. 2500 is the resolution in pulses per revolution. The next 6 means six output signals: A, B and Z with their inverted signals. L is a line driver output and the final 5 is a 5 V DC supply. The same 40 mm body is made in hollow shaft form as the E40H and E40HB series.
Where Autonics encoders are used
Servo and spindle feedback, conveyor length measurement, packaging and printing machines.
Ordering Autonics encoders: what we need
Send the complete model string from the label. If it is worn off, give the body and shaft diameter, pulses per revolution, output type, supply voltage and cable or connector style.
Facts checked against Autonics corporate profiles, October 2026.
Browse Autonics products by category: Encoders.
FAQ
Questions about the Autonics LE4S 48×48 LCD Digital Timer Multi-Function
Answers from our engineering team on installation, compatibility and integration.
01What supply can the Autonics LE4S use?
It accepts 24 to 240 V AC at 50/60 Hz and 24 to 240 V DC, within 90 to 110 percent, so one unit covers most control voltages.
02What is the output of the Autonics LE4S?
The base model has one time limit SPDT relay contact rated 250 V AC 5 A or 30 V DC 5 A resistive load.
03How does the Autonics LE4S differ from the LE4SA?
The LE4SA has two time limit contacts or one time limit and one instantaneous contact, adds star-delta and twin modes, and starts on power-on.
04What display does the Autonics LE4S have?
A backlit LCD shows the elapsed time and the set time together with the unit, mode, output contact, UP/DOWN and key lock indicators.
05What is the minimum input signal width on the Autonics LE4S?
It can be set to 1 ms or 20 ms for the RESET, START and INHIBIT inputs.