- Automation & ControlView all 2,946 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Pepperl+Fuchs
Pepperl+Fuchs UC2000-30GM-IUR2-V15 M30 Ultrasonic Sensor 2 m Analog
Description
Pepperl+Fuchs UC2000-30GM-IUR2-V15 in one paragraph
The Pepperl+Fuchs UC2000-30GM-IUR2-V15 is an M30 x 1.5 cylindrical ultrasonic sensor that measures distance to an object from 80 to 2000 mm, with an adjustment range of 120 to 2000 mm and a dead band from 0 to 80 mm. It outputs both a 4 to 20 mA current signal and a 0 to 10 V voltage signal, is made of stainless steel 1.4305 with PBT parts, and connects through a 5-pin M12 x 1 plug.
It is a single head system. A transducer of epoxy resin and hollow glass sphere mixture with polyurethane foam sends bursts at approximately 180 kHz, and a separate temperature probe plug compensates for the way sound speed changes with air temperature. Its parameterization interface, used with the ULTRA 3000 service program, allows the evaluation range, output function and other settings to be adapted.
Datasheet facts
| Parameter | Value |
|---|---|
| Part number | UC2000-30GM-IUR2-V15 |
| Sensing range | 80 to 2000 mm |
| Adjustment range | 120 to 2000 mm |
| Dead band | 0 to 80 mm |
| Standard target plate | 100 mm x 100 mm |
| Transducer frequency | approx. 180 kHz |
| Response delay | 65 ms minimum, 195 ms factory setting |
| Operating voltage | 10 to 30 V DC, ripple 10 percent peak to peak |
| Power consumption | 900 mW or less |
| Time delay before availability | 500 ms or less |
| Outputs | 1 x 4 to 20 mA, 1 x 0 to 10 V |
| Resolution | evaluation range divided by 4000, at least 0.35 mm |
| Linearity deviation | 0.2 percent of full-scale value or less |
| Repeat accuracy | 0.1 percent of full-scale value or less |
| Load impedance | current 500 ohm or less, voltage 1000 ohm or more |
| Temperature influence | 2 percent of full scale with compensation; 0.2 percent per K without |
| Interface | RS 232, 9600 bit/s, 8 data bits, no parity, 1 stop bit |
| Synchronization | bi-directional; common mode up to 30 Hz; multiplex up to 30 Hz divided by n, n up to 5 |
| Ambient temperature | -25 to 70 degrees C |
| Protection / mass | IP65 / 170 g |
| Size | 114 mm long, 30 mm diameter |
| Factory setting | A1 200 mm, A2 2000 mm, rising ramp |
Level and position tasks for the UC2000-30GM-IUR2-V15
Contactless measurement from above is the classic use: tank and silo fill level for water, slurry, bulk granules and chemicals, with the sensor mounted on a nozzle or bracket looking down. Because the 2 m range suits sumps, day tanks, hoppers and open channels, you see this type in water treatment and desalination works, chemical dosing rooms and cement or mining conveyors in Oman.
In manufacturing it measures roll diameter, loop height and stack height, and in material handling it detects pallets or vehicles. Because sound reflects from transparent and coloured surfaces alike, glass, clear film and liquids can be measured when optical sensors struggle.
How UC2000-30GM-IUR2-V15 differs from other UC ultrasonic sensors
The UC4000-30GM-IUR2-V15 has the same M30 style, plug and analog outputs but doubles the reach to 200 to 4000 mm, drops to 85 kHz, lengthens the response delay to 145 ms minimum and extends the body to 128 mm and 40 mm diameter at the head. Common-mode synchronization frequency falls from 30 Hz to 13 Hz.
The UB800-18GM40-E5-V1 is a short M18 sensor with a 50 to 800 mm range and a single PNP switching output rather than analog outputs. Choose the UC2000 when you need a continuous signal over up to 2 m.
Teaching and configuring
The sensor is shipped with an evaluation window of 200 to 2000 mm and a rising output ramp. A coded temperature and teach-in plug on the sensor lets you set the evaluation range, the output function and temperature compensation without a PC, while the RS 232 interface and the ULTRA 3000 program allow detailed parameterisation. The four LEDs show power, an object in the evaluation range and in the detection range, and faults when the plug is missing.
Wiring and mounting the UC2000-30GM-IUR2-V15
The M12 connector assigns brown to +UB and grey to sync, with the analog outputs on the remaining pins as shown on the datasheet connection diagram. Use a shielded cable. Mount the sensor square to the target and keep the sound path clear of tank walls, ladders and nozzle edges, because the beam has a cone shape and echoes from structures inside the dead zone or beam can corrupt readings. When several sensors operate close together, use synchronization or multiplex mode to avoid crosstalk.
Maintenance
Wipe the transducer face of dust, condensation or product build-up and check the connector seal. Foam, steam and strong air movement can disturb ultrasonic echoes, so verify readings against a dip stick after commissioning.
Accuracy and temperature compensation of the UC2000-30GM-IUR2-V15
The datasheet states a linearity deviation of 0.2 percent of full scale and a repeat accuracy of 0.1 percent of full scale, with resolution given as the evaluation range divided by 4000 but never finer than 0.35 mm. Sound speed in air changes with temperature, so the sensor includes a temperature probe in its coded plug. With compensation the temperature influence is held to 2 percent of full scale, whereas without the probe the drift is 0.2 percent per kelvin, which over a 30 K swing could reach 6 percent. In a hot Gulf environment that difference is significant, so leave the compensation plug fitted.
The load limits are practical: the current output drives up to 500 ohm, while the voltage output needs a load of 1000 ohm or more. A typical PLC analog card meets both.
Reading the LED states
The green LED shows power, the two yellow LEDs show whether the object is within the evaluation range and the detection range, and the red LED lights when the temperature or program plug is not connected or flashes on a fault. These indicators let a technician judge the sensor condition without a laptop, which helps in remote pump stations.
Ordering notes
Quote the full UC2000-30GM-IUR2-V15 designation, including V15, when you send your RFQ. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Documents and quotation
The datasheet for the UC2000-30GM-IUR2-V15 is attached to this page. Please send an RFQ to Seven Star LLC with the part number UC2000-30GM-IUR2-V15 and quantity.
Datasheets & Documents
- Datasheet Pepperl+Fuchs UC2000-30GM-IUR2-V15 M30 Ultrasonic Sensor 2 m Analog Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs UC2000-30GM-IUR2-V15 M30 Ultrasonic
Answers from our engineering team on installation, compatibility and integration.
01What range does the UC2000-30GM-IUR2-V15 measure?
Sensing range is 80 to 2000 mm with an adjustment range of 120 to 2000 mm and a dead band of 0 to 80 mm.
02Which outputs does it provide?
One 4 to 20 mA current output and one 0 to 10 V voltage output.
03Can it be configured without a PC?
Yes, the coded teach-in and temperature plug sets the evaluation range, output function and temperature compensation; the ULTRA 3000 program gives more options over RS 232.
04What is the protection rating and size?
IP65, 114 mm long, 30 mm diameter, 170 g, stainless steel 1.4305 housing.
05How do I request a quote?
Send an RFQ to Seven Star LLC with UC2000-30GM-IUR2-V15 and quantity.


















Reviews
There are no reviews yet.