Brand:

Metrohm 907 Titrando Potentiometric and KF Titrator

Description

Overview

Where the Metrohm 907 Titrando stands out is the range of titration modes it handles from a single compact housing. The manual lists dynamic equivalence point titration (DET), monotonic equivalence point titration (MET), endpoint titration (SET), STAT titration, volumetric Karl Fischer water determination (KFT) and plain measuring in pH, voltage, polarization current or polarization voltage. The 907 relies entirely on external dosing devices, which keeps the case small and lets each laboratory pick Dosino or Dosimat units as needed. Seven Star LLC is an independent supplier serving Oman and the GCC.

Metrohm lists two orderable versions: 2.907.0010 with one combined analog and digital measuring input and 2.907.0020 with two. This page is written around the 907 Titrando as a product line and highlights what to check before ordering.

Modes and measuring modes of the 907 Titrando

DET adds titrant in variable steps and slows down near the equivalence point, which saves time on curves with a steep jump. MET adds equal steps and is helpful for flat or unusual curves. SET stops at one or two preset endpoints. STAT holds a measured value constant by continuously adding titrant, a technique used for enzyme kinetics and for synthesis control. KFT determines water content with the polarizer, and MEAS reads concentration with or without standard addition. Each titration mode can use pH or voltage; the polarizer modes Ipol and Upol are available for DET, MET, SET and KFT.

Metrohm 907 Titrando data summary

Item 907 Titrando
Order numbers 2.907.0010 (one input), 2.907.0020 (two inputs)
Measuring cycle 100 ms
pH range minus 13 to plus 20 pH with 0.001 pH resolution
Voltage range minus 1,200 to plus 1,200 mV, plus or minus 0.2 mV
Polarization current minus 122.5 to plus 122.5 microamperes, 0.5 microampere increment
Polarization voltage minus 1,225 to plus 1,225 mV, 25 mV increment
Temperature Pt1000 minus 150 to plus 250 degrees C; NTC minus 5 to plus 250 degrees C
Dosing devices Up to 4 external Dosimat or Dosino on MSB
USB host ports 2 sockets, 500 mA each
Mains 100 to 240 V, 50 to 60 Hz, up to 45 W
Housing 142 x 227 x 231 mm, 2.7 kg, PBT plastic
Overvoltage category II, pollution degree 2

How 907 Titrando differs from 904 and 902

Compared with the 904, the 907 has no internal buret drive, so all four MSB sockets can carry external dosing devices, whereas the 904 leaves three. Weight is 2.7 kg against 2.9 kg for the single-input 904. Compared with the 902 Titrando, the 907 adds the polarizer input and therefore Karl Fischer and voltametric measurement; the 902 offers potentiometry only. If your laboratory needs both acid-base titration and water determination on the same base unit, the 907 is usually the natural pick.

Typical use in Oman and the GCC

Fuel and lubricant laboratories at refineries use Karl Fischer titration to follow water in oils, while the same unit can run total acid number titrations. Pharmaceutical and food plants rely on potentiometric assays, and utility chemists track chloride and alkalinity. Equipment that serves two disciplines is attractive for laboratories with limited bench space, a common situation in field laboratories and fabricated cabins.

Selecting accessories

For water determination you will need a Karl Fischer titration cell, a double platinum electrode and a suitable dosing unit; for potentiometry, a pH or ion-selective electrode and a stirrer. A 900 Touch Control provides a stand-alone workflow with direct generation of PDF reports, whereas OMNIS or tiamo gives database storage. Sample processors of the 814 and 815 type extend the system into automatic series analysis, and up to three control instruments can be run in parallel from the Touch Control.

Accuracy and sensor inputs

The high-ohm input has a resistance above 10 to the power 12 ohm and an offset current below 10 to the power minus 12 ampere under reference conditions, which is why ordinary glass electrodes and ion-selective membranes can be used without loading the signal. In pH mode the instrument resolves 0.001 pH with an accuracy of plus or minus 0.003 pH, excluding sensor error. In voltage mode the figures are 0.1 mV resolution and plus or minus 0.2 mV. The temperature input handles Pt1000 sensors from minus 150 to plus 250 degrees C and NTC sensors from minus 5 to plus 250 degrees C, with the NTC resistance at 25 degrees C and its B value configurable. The polarizer reads 0.1 microampere or 0.1 mV, depending on whether current or voltage is forced.

Data integrity and operation

With a Touch Control the Titrando is described as the only stand-alone titration system with an audit trail, and software control adds access rights through login and password. Methods can be stored with names of up to 32 characters in structured directories, and routine users may see only the controls they need. A context-related help key explains the display, and error messages are written in plain text with suggested remedies, which shortens training time for new analysts.

Setup and first start

Connect the controller cable, attach the dosing devices to MSB sockets and use the PREP command to rinse the cylinders. The combined analog and digital input accepts conventional sensors as well as iTrodes with the 854 iConnect. After switching on, the Titrando performs a self-diagnosis. Operate it between 5 and 45 degrees C at no more than 80 percent humidity without condensation.

Care and service

Keep the Dosino housing clean and look for air bubbles regularly. Store electrodes in their recommended electrolyte and replace Karl Fischer solutions according to the method. The device can remind you of validation or service tasks that are due, and the software records electrode calibration history so that ageing can be spotted before it affects a result.

Ordering the Metrohm 907 Titrando

When you contact Seven Star LLC please name the Metrohm 907 Titrando and say whether you need one or two measuring inputs. List the dosing units, stirrers, cells and electrodes that belong to your application so a single quotation can cover them.

Related items you may also need: Metrohm 2035 Process Analyzer | Metrohm 905 Titrando Potentiometric Titrator | Metrohm 888 Titrando Potentiometric Titrator | All Metrohm products.

Documents and quotation

The brochure for the 906 and 907 Titrando range accompanies this page as a datasheet. Please send your RFQ with the part number Metrohm 907 Titrando, the quantity and your delivery location in Oman or elsewhere in the GCC; we will respond with availability and lead time.

Other Models in the Titrando Range

Seven Star LLC supplies models from the Titrando range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Metrohm 902 Titrando Intelligent Potentiometric TitratorLiquid Analytical SystemsView details
Metrohm 904 Titrando Titrator with Internal Dosing DriveLiquid Analytical SystemsView details
Metrohm 907 Titrando Potentiometric and KF TitratorLiquid Analytical SystemsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Metrohm 907 Titrando Potentiometric and KF Titrator Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Metrohm is a Swiss maker of instruments for chemical analysis, founded in 1943 by Bertold Suhner in Herisau, where it is still headquartered. It is best known for titration and also makes ion chromatography, electrochemistry, spectroscopy and process analysers. Metrohm is owned by a foundation.

Seven Star LLC lists the Metrohm 905 Titrando, the 916 Ti-Touch and the 2035 Process Analyzer, and supplies Metrohm instruments and accessories to laboratories and plants in Oman and the GCC.

Metrohm company profile

Founded 1943, Herisau, Switzerland
Founder Bertold Suhner
Headquarters Herisau, Switzerland
Ownership Metrohm Foundation
Product families Titrando and Ti-Touch titrators, ion chromatography systems, 2035 and 2060 process analysers, electrodes

Metrohm instruments listed here

The 905 Titrando is a high-end potentiometric titrator for use with Dosino dosing units. It runs dynamic (DET), monotonic (MET) and set endpoint (SET) titrations, takes up to four 800 Dosino units, recognizes intelligent iTrode electrodes, and is operated from tiamo or OMNIS software or a Touch Control. The 2035 Process Analyzer is an online wet-chemistry analyzer for automatic analysis of samples drawn from the process.

Metrohm products we list

Family Examples
Liquid Analytical Systems 2035 Process Analyzer, 905 Titrando Potentiometric Titrator, 916 Ti-Touch Compact Potentiometric Titr…

Ordering Metrohm equipment: what we need

Metrohm article numbers follow a fixed pattern (the 905 Titrando is 2.905.0010), and that number is the best reference for instruments, electrodes and accessories. For a new application, tell us the sample, the parameter and its concentration range, the method or standard you follow, and for a process analyzer the number of sample streams and the signals your control system needs.

Facts checked against Metrohm's published company history, October 2026.

FAQ

Questions about the Metrohm 907 Titrando Potentiometric and KF Titrator

Answers from our engineering team on installation, compatibility and integration.

01Which titration modes does the Metrohm 907 Titrando support?
The manual lists DET, MET, SET, STAT and KFT titration plus MEAS, using pH, voltage, polarization current or polarization voltage as measuring modes.
02Can the 907 Titrando perform Karl Fischer titration?
Yes. The polarizer input supports volumetric Karl Fischer water determination in KFT mode, in addition to acid-base and redox titrations.
03How many dosing devices can connect to the 907 Titrando?
Up to four external Dosimat or Dosino devices can connect to the MSB sockets because the 907 has no internal dosing drive.
04Does the 907 Titrando come with one or two measuring inputs?
Metrohm lists version 2.907.0010 with one combined analog and digital input and version 2.907.0020 with two inputs.
05What is the weight and mains supply of the 907 Titrando?
It weighs 2.7 kg without accessories and runs on 100 to 240 V at 50 to 60 Hz with a maximum of 45 W.