Metrohm 831 KF Coulometer for Trace Water Analysis
Description
Overview
The Metrohm 831 KF Coulometer is a coulometric Karl Fischer instrument for measuring very small amounts of water, from the lower microgram range up to about 200 mg absolute. Instead of dosing a titrant from a burette, a coulometer generates iodine electrolytically inside the cell, and the charge needed to consume the water is converted directly into micrograms of water. Seven Star LLC is an independent supplier serving Oman and the GCC. This page draws on the Metrohm brochure that covers the 756 and 831 Coulometers and on the product page for article 2.831.0010.
How coulometric titration differs from volumetric work
Because the iodine comes from the generator electrode, the method is absolute: no titer has to be determined, and no titrant bottle needs to be refilled. That is why coulometry is the first choice when samples contain only traces of water, for example dry solvents, insulating oils, refrigerant liquids, plastics granulate or gases. Metrohm gives 10 micrograms to 200 milligrams as the working range. Larger water amounts consume the cell solution quickly and are better handled by a volumetric titrator such as the 870 or the Titrando series.
Features of the Metrohm 831 KF Coulometer
- Backlit graphical display that shows the live curve of micrograms of water against time, along with the titration parameters.
- Standard mode with only routine functions and an expert mode with the full parameter set.
- Four predefined methods and a method memory for up to 100 methods.
- Automatic conditioning and recalculation of results.
- Two RS-232 interfaces for a balance, an external printer or a computer running tiamo software.
- Seven dialog languages: English, German, French, Spanish, Italian, Portuguese and Swedish.
Specification of Metrohm 831 KF Coulometer
| Item | Value |
|---|---|
| Method | coulometric Karl Fischer titration |
| Water content range | 10 micrograms to 200 mg |
| Sample types | solid, liquid, gaseous |
| Generator cell | with diaphragm (2.831.0010) or without diaphragm (2.831.0110) |
| Predefined methods | 4 |
| Stored methods | up to 100 |
| Automatic conditioning | yes |
| Live curve | yes, micrograms water versus time |
| Recalculation of results | yes |
| Interfaces | 2 x RS-232 |
| Thermal sample preparation | manual or automated KF oven |
| Software control | tiamo (light, full, multi) via RS-232 |
| Printer | external; the 756 sister model has one built in |
| Included with 2.831.0010 | 728 magnetic stirrer and comprehensive accessories |
Choosing between the two article numbers
Metrohm offers two generator electrode types. The version with a diaphragm separates the anode and cathode compartments, which suits most routine samples and is the configuration of 2.831.0010, delivered with a 728 magnetic stirrer. The version without a diaphragm, article 2.831.0110, is delivered without the stirrer and is the sensible option for cell solutions that are formulated for diaphragm-free operation. Always check the cell solution maker’s instructions for the generator type that matches the cell solution you intend to use.
Using an oven for difficult samples
Some materials cannot go into the cell directly because they react with the iodine, dissolve poorly or release water only at high temperature. For these the brochure recommends thermal sample preparation: the sample is weighed into a vial, sealed, heated in an oven, and the evaporated water is swept by dry carrier gas into the cell. This avoids harmful solvents, side reactions and cell contamination, and it extends the life of the cell solution. The coulometer can work with the 860 KF Thermoprep for manual vial handling, with the 885 Compact Oven Sample Changer or with the 874 Oven Sample Processor for automation.
How 831 KF Coulometer differs from the 756 Coulometer
The two models share the same measuring electronics, working range and operating concept. The 756 has a printer built in and its articles 2.756.0010 and 2.756.0110 include one, whereas the 831 relies on an external printer connected through RS-232. If a printed record at the instrument is important and you do not want a separate printer, the 756 is the better match; if bench space and cost matter more, the 831 does the same analytical job.
Interfaces and data handling
Both RS-232 ports have a job. One is normally used for a balance so that the sample weight, which many methods need for a result in percent or ppm, arrives without typing; the other can drive an external printer for a hard-copy record or connect a computer where tiamo software takes over method handling, sample tables and result databases. The tiamo options in the brochure are the light, full and multi editions, which differ in how many instruments and how much data management they cover. Because the instrument has its own method memory, it keeps working as a stand-alone unit when the computer is switched off, so a power-cycled PC never interrupts a run.
Results can be recalculated after a run, for instance when a sample weight was entered wrongly. That feature is more useful than it sounds in a busy laboratory, because it avoids repeating a determination that has consumed a precious sample. The graphic display shows the curve of micrograms of water over time, so a drifting baseline or a slow side reaction is visible at once and can be corrected before the next sample.
Practical notes for Gulf laboratories
High ambient humidity is the main enemy of trace-water work in the region. Keep the cell sealed, use fresh desiccant in the drying tubes, and allow the conditioning routine to bring the drift to a low and steady figure before weighing a sample. Transformer oil laboratories at utilities, petrochemical quality departments and pharmaceutical packaging plants all benefit from a dedicated coulometer, because it reaches ranges that volumetric systems cannot resolve.
Installation and care
Fill the cell with the recommended solution, insert the generator electrode and the indicator electrode, start the stirrer and let the instrument condition. Where a 700 Dosino is attached, spent solution can be replaced at the touch of a button. Clean the diaphragm according to the manual when the drift rises and replace cell solution on schedule rather than waiting for erratic results.
Related items you may also need: Metrohm 916 Ti-Touch Compact Potentiometric Titrator | Metrohm 905 Titrando Potentiometric Titrator | Metrohm 2035 Process Analyzer | All Metrohm products.
Metrohm 831 KF Coulometer ordering checklist
- When the Metrohm 831 KF Coulometer replaces an installed unit, check the existing nameplate against the code on this page before ordering.
- Every enquiry for the Metrohm 831 KF Coulometer is answered with a written confirmation of the code and expected lead time.
- Use the attached datasheet to check the Metrohm 831 KF Coulometer ratings, dimensions and connection details against your drawings.
- We supply the Metrohm 831 KF Coulometer as part of our liquid analytical systems range to plants in Oman and the GCC.
- For critical duty, keeping one Metrohm 831 KF Coulometer as a site spare shortens downtime after a failure.
Documents and quotation
The Metrohm brochure for the 756 and 831 Coulometers, including its ordering list for the stirrer, Dosino, titration stand, oven options and tiamo software, is attached to this page. Please send your RFQ with the model name, the article number, the quantity and your delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Metrohm 831 KF Coulometer for Trace Water Analysis Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Metrohm is a Swiss maker of instruments for chemical analysis, founded in 1943 by Bertold Suhner in Herisau, where it is still headquartered. It is best known for titration and also makes ion chromatography, electrochemistry, spectroscopy and process analysers. Metrohm is owned by a foundation.
Seven Star LLC lists the Metrohm 905 Titrando, the 916 Ti-Touch and the 2035 Process Analyzer, and supplies Metrohm instruments and accessories to laboratories and plants in Oman and the GCC.
Metrohm company profile
| Founded | 1943, Herisau, Switzerland |
|---|---|
| Founder | Bertold Suhner |
| Headquarters | Herisau, Switzerland |
| Ownership | Metrohm Foundation |
| Product families | Titrando and Ti-Touch titrators, ion chromatography systems, 2035 and 2060 process analysers, electrodes |
Metrohm instruments listed here
The 905 Titrando is a high-end potentiometric titrator for use with Dosino dosing units. It runs dynamic (DET), monotonic (MET) and set endpoint (SET) titrations, takes up to four 800 Dosino units, recognizes intelligent iTrode electrodes, and is operated from tiamo or OMNIS software or a Touch Control. The 2035 Process Analyzer is an online wet-chemistry analyzer for automatic analysis of samples drawn from the process.
Metrohm products we list
| Family | Examples |
|---|---|
| Liquid Analytical Systems | 2035 Process Analyzer, 905 Titrando Potentiometric Titrator, 916 Ti-Touch Compact Potentiometric Titr… |
Ordering Metrohm equipment: what we need
Metrohm article numbers follow a fixed pattern (the 905 Titrando is 2.905.0010), and that number is the best reference for instruments, electrodes and accessories. For a new application, tell us the sample, the parameter and its concentration range, the method or standard you follow, and for a process analyzer the number of sample streams and the signals your control system needs.
Facts checked against Metrohm's published company history, October 2026.
Browse Metrohm products by category: Liquid Analytical Systems.
FAQ
Questions about the Metrohm 831 KF Coulometer for Trace Water Analysis
Answers from our engineering team on installation, compatibility and integration.
01What water range does the Metrohm 831 KF Coulometer cover?
Metrohm gives the recommended range as 10 micrograms up to 200 mg of absolute water, for solid, liquid and gaseous samples, which is the trace range.
02Does the 831 KF Coulometer need a titer determination?
No. Coulometry is an absolute method because iodine is generated electrolytically in the cell, so no titrant titer has to be determined before measuring.
03What is the difference between 2.831.0010 and 2.831.0110?
The first has a generator electrode with diaphragm and a 728 magnetic stirrer; the second has a generator electrode without diaphragm and is delivered without the stirrer.
04Can the Metrohm 831 KF Coulometer be used with a KF oven?
Yes. It works with the 860 KF Thermoprep, the 885 Compact Oven Sample Changer or the 874 Oven Sample Processor for samples that must be heated to release water.
05How does the 831 compare with the 756 Coulometer?
They share the measuring range and operation, but the 756 has a built-in printer while the 831 needs an external printer through its RS-232 interface.