Autonics SR1-1450 50 A Single-Phase Solid State Relay
Description
Overview
A heater of 10 kW at 230 V draws about 43 A, and switching it thousands of times a day would destroy a contactor. The Autonics SR1-1450 is a single-phase solid state relay that can switch 50 A at loads from 48 to 480 V AC, controlled by any 4 to 30 V DC signal such as a PLC transistor output or the SSR drive of a temperature controller. It switches silently with no moving contacts, at zero voltage crossing, so it is a standard choice for heater control and fast cycling. Seven Star LLC is an independent supplier serving Oman and the GCC.
What the code Autonics SR1-1450 says
SR1 is the single-phase relay series. The first digit 1 is the rated input voltage, 4 to 30 V DC, whereas a 4 would be 90 to 240 V AC. The second digit 4 is the rated load voltage of 48 to 480 V AC, as opposed to 2 for 24 to 240 V AC. The number 50 is the rated load current in amperes. The code has no R at the end, so the turn-on is zero cross; an R version would be random turn-on.
Specification of Autonics SR1-1450
| Item | Data |
|---|---|
| Input voltage | Rated 4 to 30 V DC, allowable 4 to 32 V DC |
| Maximum input current | 18 mA |
| Operating and releasing voltage | 4 V DC or more; 1 V DC or less |
| Turn-on type | Zero cross |
| Operate and release time | 0.5 cycle of load power plus 1 ms or less |
| Rated load voltage | 48 to 480 V AC rms, 50/60 Hz, allowable 48 to 528 V |
| Rated load current | 50 A rms resistive (AC-1) at 25 degrees C |
| Minimum load current | 0.5 A rms |
| One-cycle surge current | 800 A at 60 Hz |
| Non-repetitive I2t | 3,000 A2s |
| Peak voltage | 1,200 V non-repetitive (zero cross) |
| On-state voltage drop | 1.6 V peak or less |
| Leakage current | 10 mA rms or less at 480 V AC |
| Static dv/dt | 500 V per microsecond |
| Dielectric strength | 2,500 V AC for 1 minute |
| Ambient | minus 30 to plus 80 degrees C (DC input) |
| Terminals | Input M3.5, 0.75 to 0.96 N m; output M5, 1.6 to 2.2 N m |
| Weight | about 80 g, about 120 g packaged |
How the Autonics SR1-1450 differs from other SR1 variants
The SR1 family spans rated currents of 10, 15, 20, 25, 30, 40, 50 and 75 A, in both 24 to 240 V AC and 48 to 480 V AC load classes. At 50 A, the Autonics SR1-1450 sits near the top: its one-cycle surge rating of 800 A and I2t of 3,000 A2s compare with 160 A and 128 A2s for the 10 A model, and its heat sink must have a thermal resistance of 0.9 degrees C per watt or less, against 2.5 for the smallest units. The 75 A model needs 0.5 degrees C per watt and withstands 1,000 A. The 480 V class has a higher peak voltage rating, 1,200 V, than the 600 V of the 240 V class, and a minimum load of 0.5 A.
Heat sink and derating
An SSR drops about 1.6 V across the output when conducting, so at 50 A it dissipates around 80 watts. That heat has to leave through a heat sink or a ventilated panel. The manufacturer does not supply a heat sink, and the manual says to check thermal resistance before use and attach the relay with thermal grease. The derating curves are measured with a heat sink of 0.9 degrees C per watt or lower for the 50 A model, and the curves are UL approved. When several SSRs are mounted close together, the manual advises loading each to less than half of its rated current, or adding a cooling fan. Never touch the body or heat sink while in service, since both can be hot.
Applications in Oman and the GCC
Zero-cross SSRs are used for heater banks in ovens, furnaces, extruders, heat-tracing panels, water and oil heaters, and for resistive loads in laboratories. With a 4 to 30 V DC input, they connect directly to the SSR drive output of controllers such as the Autonics TK, TX and TC series, which supply about 11 to 13 V DC at 20 mA. In hot regions, the ambient temperature of the panel decides the usable current, so use the derating curve at the actual panel temperature, not at 25 degrees C.
Sizing the Autonics SR1-1450 for a real heater
Start from the load: divide the heater power in watts by the supply voltage to find the current, for example 15 kW at 400 V is about 37.5 A. The manual rates the relay at 50 A resistive at an ambient of 25 degrees C, so the relay is used at 75 percent of its rating, but that rating falls with panel temperature. In a Gulf panel at 50 degrees C the derating curve may allow only a fraction of the rated current, so read the curve for the specific model and the specific heat sink. A heater with a positive temperature coefficient or a cold resistance well below the hot value, such as tungsten or some ceramic elements, draws a much higher current at switch-on; the one-cycle surge rating of 800 A and the I2t of 3,000 A2s limit how large that inrush may be.
Next, check the minimum load current of 0.5 A. A small trace heater of 100 W at 230 V draws less than half an ampere and the relay may not latch reliably, in which case a smaller SSR from the same family is a better fit. For multiple heaters in one panel, remember the rule from the manual that closely mounted SSRs should be loaded to less than half of the rated current, which means that eight 40 A heaters need larger relays or more spacing than the nameplate suggests.
Finally, define the protection: a semiconductor fuse sized to the I2t figure, a thermal cutout on the heater, and an upstream contactor that opens when the temperature limit trips, since a relay that has failed shorted cannot switch the load off by itself.
Wiring
Connect the control signal to the input terminals, positive and negative, using wire of 0.5 to 1.5 mm2 and tightening to the specified torque. The load goes in series with the supply on the output terminals, using wire sized for the load current, up to 16 mm2, with crimp terminals of the round type. A CAP across the output may be needed to meet EMC rules. When the input comes from a DC supply, use an insulated and limited voltage supply, as the manual requires. Ground the panel.
Protection
An SSR can fail short-circuited, so protect the load with a thermal cutout, and use a fast semiconductor fuse sized by the I2t of 3,000 A2s. A leakage current of up to 10 mA flows even when off, so the output is never fully isolated: do not touch the load terminals even in the off state. Add a varistor across inductive loads, and for motor or transformer loads size the relay for inrush.
Maintenance
Check the heat sink, thermal grease and terminal torque at each shutdown, because loose output terminals overheat first. The green input indicator shows that the control signal is present, but it does not prove that the output is working, so measure the load current to confirm. Replace the relay if the output is stuck on or off, and record the load current and heat sink temperature at commissioning so that later readings can be compared and a slowly rising temperature is noticed before the relay fails.
Related items you may also need: Autonics E40S6-2500-6-L-5 Rotary Encoder Incremental | SICK WTB250-2P2441 Background Suppression Sensor | ifm OGH580 Diffuse Sensor BGS, 200 mm, Metal Housing, M18 | All Autonics products.
Documents and quotation
The SR1 series product manual covering the Autonics SR1-1450 is attached with ordering information, specifications, derating curves and dimensions. Send an RFQ with the part number Autonics SR1-1450, quantity and delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Autonics SR1-1450 50 A Single-Phase Solid State Relay Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Autonics is a South Korean maker of sensors and controllers, founded in 1977 as a small engineering business making controllers for looms. It took the Autonics name in 1988 and opened a new corporate headquarters in Busan in 2014. Autonics makes proximity and photoelectric sensors, rotary encoders, temperature controllers, counters, timers and stepper motor systems, with factories in Busan and Yangsan.
Seven Star LLC lists the Autonics E40S6-2500-6-L-5 incremental rotary encoder and supplies Autonics sensors and control devices in Oman and the GCC.
Autonics company profile
| Founded | 1977, South Korea |
|---|---|
| Current name | Autonics, since 1988 |
| Headquarters | Busan, South Korea |
| Factories | Busan and Yangsan |
| Product families | E40 and E50 rotary encoders, PR proximity sensors, BJ photoelectric sensors, TK temperature controllers |
Milestones
- 1977: The company is founded.
- 1988: Renamed Autonics Corporation.
- 2014: Opens its Busan headquarters.
Reading the Autonics E40S encoder code
E40S is the 40 mm diameter shaft-type incremental encoder, and the 6 that follows is the 6 mm shaft. 2500 is the resolution in pulses per revolution. The next 6 means six output signals: A, B and Z with their inverted signals. L is a line driver output and the final 5 is a 5 V DC supply. The same 40 mm body is made in hollow shaft form as the E40H and E40HB series.
Where Autonics encoders are used
Servo and spindle feedback, conveyor length measurement, packaging and printing machines.
Ordering Autonics encoders: what we need
Send the complete model string from the label. If it is worn off, give the body and shaft diameter, pulses per revolution, output type, supply voltage and cable or connector style.
Facts checked against Autonics corporate profiles, October 2026.
Browse Autonics products by category: Encoders.
FAQ
Questions about the Autonics SR1-1450 50 A Single-Phase Solid State
Answers from our engineering team on installation, compatibility and integration.
01What load can the Autonics SR1-1450 switch?
It is rated 50 A rms resistive at 25 degrees C on loads from 48 to 480 V AC, 50/60 Hz, with a minimum load current of 0.5 A.
02What control signal does the Autonics SR1-1450 need?
A DC input of 4 to 30 V DC, drawing 18 mA at most, which suits PLC outputs and temperature controller SSR drive outputs.
03Is the Autonics SR1-1450 zero cross or random turn-on?
It is zero cross turn-on, because the code has no R at the end; operate and release times are 0.5 cycle of load power plus 1 ms or less.
04Does the Autonics SR1-1450 include a heat sink?
No, the manual states that Autonics does not provide a heat sink and asks for one with thermal resistance of 0.9 degrees C per watt or lower for 50 A.
05What surge current can the Autonics SR1-1450 withstand?
The manual gives 800 A for one cycle at 60 Hz and a non-repetitive I2t of 3,000 A2s.