Winsonic DAU02-PNET-16DO PROFINET Remote I/O 16 DO Module
Description
Winsonic DAU02-PNET-16DO is a PROFINET remote I/O module with sixteen open-collector digital outputs. It lets a PROFINET controller switch relays, indicator lamps, solenoid coils and similar low-current loads at a distant cabinet over a single Ethernet cable, and it adds MQTT, RESTful and SNMP access so the same output states can be reached from supervisory or cloud software. Seven Star LLC is the authorized representative of Winsonic in Oman and serves customers across the GCC.
Where the Winsonic DAU02-PNET-16DO fits
Outputs are usually the part of a project that grows late, when a new alarm beacon, interposing relay or valve coil is added far from the PLC. Rather than running more cable to the main rack, a designer can drop the DAU02-PNET-16DO beside the equipment. The module behaves as a PROFINET Device, appears in the engineering tool through the manufacturer’s device description file, and exposes its sixteen sink-type channels as output bits.
Highlights
- 16 open-collector (sink type) outputs on screw-fastened Euroblock terminals.
- Load voltage 4.5 to 32 VDC, 0.3 A maximum, 300 mA per channel.
- DO mode or pulse-output mode, pulse frequency up to 500 Hz.
- Over-current, over-temperature and over-voltage protection.
- Two Ethernet ports with daisy-chain capability.
Winsonic DAU02-PNET-16DO output and system data
| Model | DAU02-PNET-16DO |
|---|---|
| Digital output channels | 16 |
| Output type | Open collector, sink type |
| Load voltage | 4.5 to 32 VDC, 0.3 A maximum |
| Current rating | 300 mA per channel |
| I/O mode | DO or pulse output |
| Pulse output frequency | 500 Hz maximum |
| Over-current protection | 400 to 1000 mA per channel at 25 degrees C |
| Over-temperature shutdown | 175 to 220 degrees C minimum |
| Over-voltage protection | 45 to 60 VDC |
| Industrial protocol | PROFINET Device |
| IoT protocols | MQTT, RESTful API, SNMP V1.0 |
| Cloud connectivity | AWS, Azure, AIoTera |
| Ethernet ports | 2 x 10/100BaseT(X), RJ-45, daisy-chain capable |
| Magnetic isolation | 1.5 kV built-in |
| Configuration | Web console (HTTP), Windows utility (device search) |
| Security | Access control list |
| LED indicators | Power, Status, Port 1, Port 2 |
| Power input | 12 to 36 VDC, one input, screw-fastened Euroblock terminal |
| Housing | Plastic |
| Dimensions | 27.8 x 124 x 84 mm |
| Weight | 200 g |
| Mounting | DIN-rail or wall |
| Operating temperature | -10 to 60 degrees C standard; -40 to 75 degrees C wide-temperature models |
| Storage temperature | -40 to 85 degrees C |
| Humidity | 5 to 95 percent, non-condensing |
| Safety / EMC | UL 508; EN 55032/24, EN 61000-6-2/-6-4; ESD 4 kV contact, 8 kV air |
| Green | RoHS, WEEE |
Protection features explained
The three protection ratings on the DAU02-PNET-16DO sheet matter in practice. Over-current protection trips between 400 and 1000 mA per channel at 25 degrees C, comfortably above the 300 mA rating, so a shorted coil does not take the whole module down. Over-temperature shutdown acts at a junction temperature of 175 to 220 degrees C minimum. Over-voltage protection clamps at 45 to 60 VDC, which helps when inductive loads are switched. None of these replaces a flyback diode or relay interface where heavy inductive loads are used.
How DAU02-PNET-16DO differs from DAU02-PNET-16DI and DAU02-PNET-8AI
Where DAU02-PNET-16DI reads sixteen contacts and DAU02-PNET-8AI measures eight analogue signals at 16 bit, the DAU02-PNET-16DO drives loads. It is the only one of the three with a load voltage figure (4.5 to 32 VDC) and a pulse output of up to 500 Hz. All three share the same plastic housing, the 12 to 36 VDC supply and the two-port Ethernet interface, so mixed stations can be assembled from one family.
Where to use it
Sixteen sink outputs are useful for beacon and horn control at pump stations, interposing relay drives in motor control centres, and indicator lamps on water-treatment panels in Oman. Pulse mode can drive a dosing pump or stepper-style input that needs a train of pulses up to 500 Hz. Because it is sink type, the load connects between a positive supply and the output terminal.
Specifying and commissioning
Check that each load stays below 300 mA and that the external load supply falls within 4.5 to 32 VDC. Add flyback protection to coils. Mount on a DIN rail, power from 12 to 36 VDC, wire loads with 16 to 26 AWG conductors and connect Ethernet. Use the Auto-Search RIO utility or the web console to set the network address, import the device description file into the PLC tool and test each channel before connecting field loads.
Maintenance
Inspect terminals for tightness, check that protection has not been repeatedly tripped by a faulty load, and keep the configuration backed up. SNMP V1.0 helps with remote status checks. During planned shutdowns, exercise each output once and compare the actual load state with the PLC bit, and review the Status and port LEDs for signs of intermittent network cabling that could cause unexpected output behaviour.
Interfacing loads to the DAU02-PNET-16DO
Because the outputs are open-collector sinks, they switch the negative side of the load. A small interposing relay with a flyback diode across its coil is the safest pairing for contactors and larger solenoids, and the relay contacts then handle any mains or higher-current duty. Lamps and beacons should be sized so the combined inrush stays below the 300 mA channel rating, since an incandescent filament draws several times its running current when cold. Keep a spare module on the shelf for critical stations and record which outputs are wired, so a replacement can be configured within minutes after a failure in remote pump stations. Test every output with the loads disconnected first, then reconnect them one at a time while watching the current, so that a wiring mistake or a shorted coil is found before it can trip the channel protection or disturb the process.
Documents and quotation
We can supply the manufacturer datasheet for the DAU02-PNET-16DO as a PDF. Please send an RFQ with part number DAU02-PNET-16DO, the quantity and the delivery destination.
When you send the RFQ, also mention the PROFINET controller you use, the GSDML file version already in your engineering project and whether spare modules are needed for the site. We will confirm the label details, the current hardware revision and the lead time before the order is placed.
Other Models in the Dau02 Pnet Range
Seven Star LLC supplies models from the Dau02 Pnet range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Winsonic DAU02-PNET-16DI PROFINET Remote I/O 16 DI Module | Industrial Communications | View details |
| Winsonic DAU02-PNET-16DO PROFINET Remote I/O 16 DO Module | Industrial Communications | You are viewing this model |
Datasheets & Documents
- Datasheet Winsonic DAU02-PNET-16DO PROFINET Remote I/O 16 DO Module Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rail-grade Ethernet switches with M12 connectors, industrial cellular routers and panel PCs are the Winsonic products buyers ask us for most. Winsonic is known as a maker of industrial LCD monitors and touch displays, and the products listed here add networking and computing hardware for places where office equipment does not survive: trains and buses, roadside cabinets, pump stations and factory floors.
Seven Star LLC is the Winsonic agency for Oman and the GCC and lists Winsonic EN 50155 switches, 4G and 5G routers and gateways, SFP transceivers, panel PCs and rack mount monitors.
Winsonic product families
The M12 switches on this page are specified to EN 50155, the standard for electronic equipment on rail vehicles. Listed models include the L2 managed NE10002 and the NE10003 in IP68 housings, the unmanaged NE10004 with 10G ports and IP65 sealing, the unmanaged NE10005 and the 5-port IP68 NE10006, with PoE+ or PoE++ ports depending on the model. On the cellular side the listing covers NE24 series industrial cellular routers and edge gateways, the NE20001 vehicle-grade 5G transit gateway and the NE31001 outdoor LTE-A router. WSFP Gigabit SFP transceivers provide the fiber uplinks. Computing and display products include the PZB zero bezel panel PC and the RM rack mount monitor, next to the flush mount and zero bezel LCD monitors Winsonic builds for industrial use.
Winsonic series at a glance
| Series | Use | Models listed on this site |
|---|---|---|
| EN 50155 M12 switches | Rail-grade switches with M12 connectors, IP65 or IP68, PoE+ or PoE++ | NE10001, NE10002, NE10003, NE10004, NE10005, NE10006 |
| Industrial Ethernet switches | L3 and L2 managed ring switches and unmanaged switches, with PoE and SFP or SFP+ uplinks | NE11001, NE11002, NE11003, NE11004, NE11005, NE11006, NE11007, NE11008, NE11009 |
| Cellular VPN routers | Industrial 4G and 5G routers, single or dual SIM | NE21001, NE22001, NE22002, NE22003, NE22004, NE22005, NE22006, NE22007 |
| Gateways | 5G EN 50155 transit gateway, edge computing and energy gateways | NE20001, NE24001, NE24002, NE24003, NE24004, NE24005 |
| Outdoor and indoor routers | LTE-A outdoor router and AX3000 WiFi router | NE31001, NE31002 |
| SFP and SFP+ transceivers | Gigabit, SONET/SDH and 10G optical modules | WSFP-C7-M85, WSFP-C7-S13, WSFP-C8-S35, WSFP-C8-S53, WSFP-E7-S13, WSPP-H7-M85, WSPP-H7-S13 |
| Panel PCs and monitors | 32 inch zero bezel panel PC and 27 inch 4K rack mount monitor | PZB32014, RM2705 |
Where Winsonic equipment is used
Typical uses are on-board networks for trains, metro cars and buses, wayside cabinets, traffic management, remote pump stations and water plants, energy metering at unmanned sites, and machine monitoring and operator stations in factories.
Ordering Winsonic switches and routers: what we need
Send the complete part number, including the digits after the hyphen, because they separate variants of the same base model. Where you are still selecting, give us:
- port count, port speed and connector type (M12 coding or RJ45)
- PoE power needed per port and the supply voltage available
- managed or unmanaged operation, and the IP rating required
- for routers: mobile operator, SIM count, serial or Ethernet interfaces
- for panel PCs: screen size, touch type, processor and mounting
Series and model data on this page come from the Winsonic product pages and manufacturer documents published on omansevenstar.com.
Browse Winsonic products by category: Industrial Communications, Industrial Computer, Human Machine Interface (HMI) Displays.
FAQ
Questions about the Winsonic DAU02-PNET-16DO PROFINET Remote I/O 16 DO
Answers from our engineering team on installation, compatibility and integration.
01What output type does the Winsonic DAU02-PNET-16DO use?
It has 16 open-collector sink-type outputs, with a load voltage of 4.5 to 32 VDC and 0.3 A maximum, 300 mA per channel.
02Can the DAU02-PNET-16DO generate pulses?
Yes, each output can work in DO or pulse-output mode, with a maximum pulse output frequency of 500 Hz.
03What protections does the DAU02-PNET-16DO include?
Over-current protection at 400 to 1000 mA per channel at 25 degrees C, over-temperature shutdown at 175 to 220 degrees C minimum, and over-voltage protection at 45 to 60 VDC.
04Which network interfaces does the DAU02-PNET-16DO offer?
A PROFINET Device interface over two 10/100 RJ-45 ports, plus MQTT, RESTful API and SNMP V1.0 and AWS, Azure and AIoTera cloud links.
05What is the supply range of the DAU02-PNET-16DO?
The module is powered from 12 to 36 VDC through a screw-fastened Euroblock terminal; the datasheet lists its power consumption as to be determined.