- Automation & ControlView all 3,079 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Winsonic
Winsonic DAU02-PNET-16DI PROFINET Remote I/O 16 DI Module
Description
The Winsonic DAU02-PNET-16DI is a PROFINET remote I/O module that brings sixteen digital inputs onto an Ethernet network from a compact DIN-rail housing. If a PLC or controller needs more switch, limit or status signals than its own rack provides, this module collects them at the machine and sends them back as PROFINET data, with the added option of MQTT and RESTful access for cloud or dashboard use. Seven Star LLC is the authorized representative of Winsonic in Oman and serves customers across the GCC.
Role of the Winsonic DAU02-PNET-16DI in a control system
A remote I/O block reduces wiring cost: field contacts terminate in the nearest cabinet and only one Ethernet cable returns to the controller. The DAU02-PNET-16DI is the input-only member of the DAU02 PROFINET series, dedicated to sixteen digital channels that accept either dry contacts or wet (NPN) contacts. Every channel can work as a plain digital input or as an event counter, so the same module can count pulses from a flow meter or production sensor.
Key capabilities
- 16 digital input channels on screw-fastened Euroblock terminals.
- Sensor types: dry contact and wet contact (NPN), DI or event counter mode.
- PROFINET Device interface plus MQTT, RESTful API and SNMP V1.0.
- Cloud connectivity for AWS, Azure and AIoTera.
- Two-port Ethernet switch for daisy-chain topologies.
- Web-browser configuration and the Auto-Search RIO utility for mass deployment.
Specifications for Winsonic DAU02-PNET-16DI
| Model | DAU02-PNET-16DI |
|---|---|
| Digital input channels | 16 |
| Input connector | Screw-fastened Euroblock terminal |
| Sensor type | Dry contact; wet contact (NPN) |
| I/O mode | DI or event counter |
| Dry contact | On: short to GND; Off: open |
| Wet contact (DI to common ground) | On: 0 to 1 VDC; Off: 4 to 24 VDC |
| Industrial protocol | PROFINET Device |
| IoT protocols | MQTT, RESTful API, SNMP V1.0 |
| Cloud connectivity | AWS, Azure, AIoTera |
| Ethernet ports | 2 x 10/100BaseT(X), RJ-45, daisy-chain capable |
| Magnetic isolation | 1.5 kV built-in |
| Configuration | Web console (HTTP), Windows utility (device search) |
| Security | Access control list |
| LED indicators | Power, Status, Port 1, Port 2 |
| Power input | 12 to 36 VDC, one input, screw-fastened Euroblock terminal |
| Housing | Plastic |
| Dimensions | 27.8 x 124 x 84 mm |
| Weight | 200 g |
| Mounting | DIN-rail or wall |
| Operating temperature | -10 to 60 degrees C standard; -40 to 75 degrees C wide-temperature models |
| Storage temperature | -40 to 85 degrees C |
| Humidity | 5 to 95 percent, non-condensing |
| Safety / EMC | UL 508; EN 55032/24, EN 61000-6-2/-6-4; ESD 4 kV contact, 8 kV air |
| Green | RoHS, WEEE |
How DAU02-PNET-16DI differs from the other DAU02 PROFINET modules
The DAU02 series uses one housing and one communications platform, so the difference is the channel type. Compared with DAU02-PNET-16DO, which offers sixteen open-collector sink outputs rated 4.5 to 32 VDC at 300 mA per channel, the DAU02-PNET-16DI only senses. Compared with DAU02-PNET-8AI, which has eight differential analogue inputs at 16-bit resolution, the DAU02-PNET-16DI provides twice as many channels but only on/off information. Choose it when the field signal is a contact or an NPN proximity sensor, and pair it with an output module when the cabinet also needs actuation.
Typical uses in Oman and the GCC
Sixteen digital inputs suit status monitoring of pump skids, motor starters, valve limit switches, door contacts and tank level switches. In water and wastewater plants, the DAU02-PNET-16DI can collect lifting-station signals and report them over PROFINET. In oil and gas facilities it can gather auxiliary contacts in a non-classified cabinet. In manufacturing it fits conveyor and packaging lines where pulses from sensors are counted by the event-counter mode.
Selection notes
Confirm that your controller supports PROFINET device import and obtain the device description file from the manufacturer. Check that sensors are dry or NPN wet types, and verify the voltage thresholds: a wet contact reads on at 0 to 1 VDC and off at 4 to 24 VDC. Use a standard operating temperature model in conditioned rooms and ask about wide-temperature versions for outdoor kiosks, because the datasheet separates the two ranges.
Installation and commissioning
Mount the module on a DIN rail or screw it to a wall, wire the 12 to 36 VDC supply to the Euroblock terminal and connect field contacts with 16 to 26 AWG cable. Connect Ethernet port 1 or 2 and daisy-chain onward to the next device if required. Use the Auto-Search RIO utility to find the module, assign the network address through the web console and check the LED states: power, status and the two port LEDs.
Maintenance and diagnostics
With no moving parts, service is limited to terminal tightness checks, cable inspection and firmware or configuration backups. SNMP V1.0 lets a network management system watch the module, and the access control list restricts who may reach it. Keep a configuration record for each module so a spare can be loaded quickly.
Wiring and counting tips for the DAU02-PNET-16DI
Dry contacts connect between the input and ground and read On when shorted to GND; wet NPN sensors share the common ground and read On at 0 to 1 VDC. Keep sensor cables separate from motor and drive power wiring to limit noise, and use shielded cable on long runs. Event-counter mode is helpful for production counts, but the datasheet sets the module apart from a dedicated high-speed counter card, so confirm that your pulse rate suits an Ethernet remote I/O before relying on it. Label each terminal with the tag name used in the PLC program, and keep a printed channel list inside the cabinet door so that fault finding does not depend on the engineering laptop. Switching and contact bounce on mechanical limit switches can cause false counts, so add debounce logic in the controller where needed.
Documents and quotation
We can provide the manufacturer datasheet for the DAU02-PNET-16DI as a PDF. Send the part number DAU02-PNET-16DI, quantity and delivery destination in your RFQ.
Datasheets & Documents
- Datasheet Winsonic DAU02-PNET-16DI PROFINET Remote I/O 16 DI Module Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rail-grade Ethernet switches with M12 connectors, industrial cellular routers and panel PCs are the Winsonic products buyers ask us for most. Winsonic is known as a maker of industrial LCD monitors and touch displays, and the products listed here add networking and computing hardware for places where office equipment does not survive: trains and buses, roadside cabinets, pump stations and factory floors.
Seven Star LLC is the Winsonic agency for Oman and the GCC and lists Winsonic EN 50155 switches, 4G and 5G routers and gateways, SFP transceivers, panel PCs and rack mount monitors.
Winsonic product families
The M12 switches on this page are specified to EN 50155, the standard for electronic equipment on rail vehicles. Listed models include the L2 managed NE10002 and the NE10003 in IP68 housings, the unmanaged NE10004 with 10G ports and IP65 sealing, the unmanaged NE10005 and the 5-port IP68 NE10006, with PoE+ or PoE++ ports depending on the model. On the cellular side the listing covers NE24 series industrial cellular routers and edge gateways, the NE20001 vehicle-grade 5G transit gateway and the NE31001 outdoor LTE-A router. WSFP Gigabit SFP transceivers provide the fiber uplinks. Computing and display products include the PZB zero bezel panel PC and the RM rack mount monitor, next to the flush mount and zero bezel LCD monitors Winsonic builds for industrial use.
Winsonic series at a glance
| Series | Use | Models listed on this site |
|---|---|---|
| EN 50155 M12 switches | Rail-grade switches with M12 connectors, IP65 or IP68, PoE+ or PoE++ | NE10001, NE10002, NE10003, NE10004, NE10005, NE10006 |
| Industrial Ethernet switches | L3 and L2 managed ring switches and unmanaged switches, with PoE and SFP or SFP+ uplinks | NE11001, NE11002, NE11003, NE11004, NE11005, NE11006, NE11007, NE11008, NE11009 |
| Cellular VPN routers | Industrial 4G and 5G routers, single or dual SIM | NE21001, NE22001, NE22002, NE22003, NE22004, NE22005, NE22006, NE22007 |
| Gateways | 5G EN 50155 transit gateway, edge computing and energy gateways | NE20001, NE24001, NE24002, NE24003, NE24004, NE24005 |
| Outdoor and indoor routers | LTE-A outdoor router and AX3000 WiFi router | NE31001, NE31002 |
| SFP and SFP+ transceivers | Gigabit, SONET/SDH and 10G optical modules | WSFP-C7-M85, WSFP-C7-S13, WSFP-C8-S35, WSFP-C8-S53, WSFP-E7-S13, WSPP-H7-M85, WSPP-H7-S13 |
| Panel PCs and monitors | 32 inch zero bezel panel PC and 27 inch 4K rack mount monitor | PZB32014, RM2705 |
Where Winsonic equipment is used
Typical uses are on-board networks for trains, metro cars and buses, wayside cabinets, traffic management, remote pump stations and water plants, energy metering at unmanned sites, and machine monitoring and operator stations in factories.
Ordering Winsonic switches and routers: what we need
Send the complete part number, including the digits after the hyphen, because they separate variants of the same base model. Where you are still selecting, give us:
- port count, port speed and connector type (M12 coding or RJ45)
- PoE power needed per port and the supply voltage available
- managed or unmanaged operation, and the IP rating required
- for routers: mobile operator, SIM count, serial or Ethernet interfaces
- for panel PCs: screen size, touch type, processor and mounting
Series and model data on this page come from the Winsonic product pages and manufacturer documents published on omansevenstar.com.
Browse Winsonic products by category: Industrial Communications, Industrial Computer, Human Machine Interface (HMI) Displays.
FAQ
Questions about the Winsonic DAU02-PNET-16DI PROFINET Remote I/O 16 DI
Answers from our engineering team on installation, compatibility and integration.
01How many inputs does the Winsonic DAU02-PNET-16DI provide?
It provides 16 digital input channels on Euroblock terminals, usable as plain inputs or as event counters, with dry or NPN wet contacts.
02What are the wet contact thresholds of the DAU02-PNET-16DI?
For wet contacts connected to common ground, the datasheet lists On as 0 to 1 VDC and Off as 4 to 24 VDC.
03Which protocols does the DAU02-PNET-16DI support?
It acts as a PROFINET Device and also supports MQTT, a RESTful API and SNMP V1.0, with AWS, Azure and AIoTera cloud connectivity.
04What supply and mounting does the DAU02-PNET-16DI use?
It runs from 12 to 36 VDC on a screw Euroblock terminal and mounts on a DIN rail or wall in a 27.8 x 124 x 84 mm plastic housing.
05Can the DAU02-PNET-16DI be daisy-chained?
Yes, its two 10/100 RJ-45 Ethernet ports act as a built-in switch so modules can be chained without an external switch.


















Reviews
There are no reviews yet.