Brand: Weidmüller
Weidmuller 1175980000 ACT20M-CI-CO-S Signal Isolator
Description
Weidmuller 1175980000 ACT20M-CI-CO-S: fixed 0/4-20 mA isolator
Weidmuller 1175980000 is the ACT20M-CI-CO-S, a non-adjustable DC isolating amplifier for standard current signals. It linearly converts a 0 to 20 mA or 4 to 20 mA input into the same range at the output and galvanically isolates the two circuits and the power supply (3-way isolation). There is no DIP switch and no software: the module follows the input range automatically, so it can be installed and forgotten, which is the main reason maintenance teams like fixed-function isolators.
Details from the 1175980000 datasheet
The input is a current source or a 4-wire sensor with its own supply, with 70 ohm input resistance and a voltage drop of less than 1.5 V. The output is an active current signal that can drive up to 600 ohm at a maximum of 23 mA; the connected control input must be passive. Accuracy is better than 0.05 percent of the range, the temperature coefficient is 0.01 percent per C at most, the step response is 7 ms or less and the cut-off frequency is 100 Hz at minus 3 dB. Supply is 24 V DC plus or minus 30 percent at the terminals or through the CH20M rail bus, with a nominal power consumption of 1.2 VA, 0.8 W maximum and 0.45 W typical. The housing is 6.1 mm wide, 112.5 mm high and 114.3 mm deep and weighs 87 g.
Technical summary of 1175980000
| Parameter | Value |
|---|---|
| Order No. / Type | 1175980000 / ACT20M-CI-CO-S |
| Version | Analogue isolating amplifier, 0(4)-20 mA in, 0(4)-20 mA out |
| Input | 1; current source or 4-wire sensor with own supply |
| Input resistance / voltage drop | 70 ohm / less than 1.5 V |
| Output | 1; active current, up to 600 ohm at 23 mA |
| Accuracy | less than 0.05 percent of range |
| Step response / cut-off | 7 ms or less / 100 Hz |
| Supply | 24 V DC plus or minus 30 percent, terminal or CH20M bus |
| Power | 0.45 W typical; 0.8 W maximum; 1.2 VA nominal |
| Isolation | 3-way; 2.5 kV rms for 1 min; 300 V rms |
| Configuration | none |
| Weight | 87 g |
| Temperature | operating minus 25 to 70 C; storage minus 40 to 85 C |
| Ex marking | II 3 G Ex nA IIC T4 Gc |
| Terminals | screw, 0.5 to 2.5 mm², 0.4 to 0.6 Nm |
| Approvals | cULus E337701 |
| Standards | EN 61326-1; IEC 61010-1 |
How 1175980000 differs from siblings
Unlike the ACT20M-AI-AO-S (1176000000), this module has no DIP switch, no voltage ranges and no sensor supply: it expects an active 4-wire current source. Unlike the loop-powered ACT20M-CI-CO-ILP-S (1176070000) it needs 24 V DC and is 3-way isolated, so supply, input and output are all separated. It is 7 g heavier than the configurable version, and its accuracy of 0.05 percent is twice as good as the 0.1 percent of the loop-powered module. The datasheet also names a two-output variant, the CI-2CO-S, with 4-way isolation.
Applications for the 1175980000 module
It is the standard choice for passing a 4 to 20 mA signal from a transmitter with its own supply to a second system, for example from a flow computer analogue output to a DCS, or from a DCS output to a variable-speed drive. Gulf process plants use it where an analogue signal travels between buildings with different earth potentials, because the 2.5 kV isolation breaks the ground loop.
Installing 1175980000
Mount the module on TS 35 rail, optionally on the CH20M rail bus to share the 24 V DC supply. Wire the screw terminals with 0.5 to 2.5 mm² conductors and tighten to 0.4 to 0.6 Nm. Check that the loop load stays below 600 ohm on the output and that the input source can drive the 70 ohm input resistance with the stated voltage drop below 1.5 V.
Servicing 1175980000
No adjustment is needed. If a loop reads low, measure the output current in series and compare with the input; typical causes are a high load resistance or a loose terminal.
Why choose a fixed isolator such as 1175980000
Configurable devices are flexible but they introduce risk: a DIP switch bumped during maintenance, or a software file that was lost. A non-adjustable isolator removes these risks, because the unit has one function and is documented by its type label alone. For plants that run safety-relevant or custody-related signals, fewer configuration steps means fewer audit findings. The datasheet shows that the module has no configuration (configuration: none) and an accuracy of 0.05 percent, which is adequate for most monitoring and control loops.
Another benefit is stock reduction. One part number covers every 4 to 20 mA to 4 to 20 mA isolation task on site, so the spare shelf needs one item rather than a range of configured devices. Because the module slides onto the CH20M mounting-rail bus, the 24 V supply is distributed through the rail, which eliminates jumper wires and speeds up installation of several modules side by side. Without the rail bus the supply is wired to the terminals directly, and the nominal power of 1.2 VA must be considered when sizing the supply for a row of modules.
Note that the datasheet lists a MTBF figure and that no SIL rating per IEC 61508 applies, so the module should not be used as part of a safety instrumented function without further justification by the plant.
Wiring example for 1175980000
A typical loop: the transmitter output goes to the input terminals, the output terminals go to a DCS analogue input that provides its own supply path (passive input), and 24 V DC goes to the supply terminals. If the receiving device actively drives the loop, the isolator output cannot be used because the datasheet requires a passive control input.
Documents and quotation
The datasheet for 1175980000 is provided with this page. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Please send an RFQ with 1175980000, quantity and delivery location to receive a quotation.
Ordering Checklist for the Weidmüller 1175980000
Before you ask for a quotation for the Weidmüller 1175980000, check the full order code on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If this is an upgrade rather than a like-for-like swap, tell us the existing make and model so that mounting, wiring and connection details can be checked against the isolator & barrier already installed. For multi-unit orders, list the quantity per site and the delivery location in Oman or the wider GCC, so packing, paperwork and lead time can be confirmed in a single quotation.
Datasheets & Documents
- Datasheet Weidmuller 1175980000 ACT20M-CI-CO-S Signal Isolator Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Weidmüller is a German family-owned maker of electrical connection and industrial electronics products, headquartered in Detmold. The company dates from 1850 and was re-established in Detmold in 1948; it specialised in terminal blocks from the 1940s onward. Weidmüller makes Klippon terminal blocks, power supplies, remote I/O and enclosures, and reported over one billion euros in revenue in 2023.
Seven Star LLC lists Weidmüller PRO MAX power supplies and SAK terminal blocks, and supplies Weidmüller components to panel shops and plants in Oman and the GCC.
Weidmüller company profile
| Founded | 1850, Germany |
|---|---|
| Headquarters | Detmold, Germany (since 1948) |
| Ownership | Family-owned |
| Revenue | Over €1 billion (2023) |
| Product families | Klippon Connect terminal blocks, PRO MAX and PRO TOP power supplies, u-remote I/O and fieldbus couplers, Klippon enclosures, connectors and tools |
Milestones
- 1850: Weidmüller is founded.
- 1948: The company is re-established in Detmold.
Weidmüller products listed here
The listed power supplies are DIN rail switch-mode units with 24 V DC output: a PRO MAX single-phase unit rated 180 W and 7.5 A (85 to 277 V AC input), and a PRO MAX3 three-phase unit rated 240 W and 10 A (320 to 575 V AC input). The SAK series is the screw clamp feed-through terminal block family found in many existing panels. Weidmüller now flags several SAK types as being phased out and names a replacement for some of them.
Weidmüller products we list
Ordering Weidmüller parts: what we need
Weidmüller identifies every item by a ten-digit order number, and that number is the surest way to quote. Without it, send the type printed on the part. For power supplies add input voltage and phases, output voltage and current. For terminal blocks add the conductor cross-section, color, and the end plates, cross-connections and markers you need, since accessories are specific to each series.
Facts checked against Weidmüller milestone lists and distributor profiles, October 2026.
Browse Weidmüller products by category: Electrical & Power Modules.
FAQ
Questions about the Weidmuller 1175980000 ACT20M-CI-CO-S Signal Isolator
Answers from our engineering team on installation, compatibility and integration.
01Is 1175980000 adjustable?
No. The datasheet describes it as a non-adjustable isolating amplifier with 0 to 20 mA or 4 to 20 mA on both sides and no configuration.
02What source can feed its input?
A current source or a 4-wire sensor with its own supply; the input resistance is 70 ohm with less than 1.5 V drop.
03What load can the output drive?
Up to 600 ohm at a maximum of 23 mA, as an active output into a passive control input.
04What isolation does it provide?
3-way isolation between supply, input and output, with 2.5 kV rms for 1 minute and 300 V rms rated voltage.
05How wide and heavy is it?
6.1 mm wide, 112.5 mm high, 114.3 mm deep and 87 g.