Brand: Moore Industries
Moore Industries SST/4-20MA/2X4-20MA/24DC/-EP [DIN] Splitter
Description
Moore Industries SST/4-20MA/2X4-20MA/24DC/-EP [DIN]: SIL-capable splitter for safety loops
Moore Industries SST/4-20MA/2X4-20MA/24DC/-EP [DIN] is a four-wire, line-powered safety isolator and splitter from the FS Functional Safety Series. It takes a 4-20 mA signal, with HART data, from a field transmitter and delivers two fully isolated 4-20 mA outputs, one for the safety system and one for the control system or a monitoring system. The -EP option means that the outputs are powered by an external source rather than from the unit.
Splitting the signal this way isolates the SIS from the basic process control system, so a disconnection or failure on one output does not affect the other output loop.
The ordering string makes the configuration clear: 4-20MA at the input, 2X4-20MA at the output (two channels), 24DC as the power supply, and -EP as the option. Because the supply is a separate 24 V DC feed, the SST can continue to work even if one of the output loops is open or being serviced.
What the SST brings to SST/4-20MA/2X4-20MA/24DC/-EP [DIN]
- HART pass-through: HART data from the field transmitter is available on either side, rather than being stripped as with many isolators.
- 1500 Vrms test isolation to protect safety I/O cards from surges and transients.
- FMEDA data from exida available on request for the safety practitioner.
- Standard 20 V/m RFI/EMI protection and a 100 ms response.
- Optional loop maintenance diode, reverse output and HART options are listed for other codes; this one adds external power.
The SST can also provide loop power to a 2-wire transmitter connected to its input.
SST/4-20MA/2X4-20MA/24DC/-EP [DIN] specification summary
Values are taken from the SSX/SST datasheet.
| Parameter | Value for SST/4-20MA/2X4-20MA/24DC/-EP [DIN] |
|---|---|
| Model code | SST/4-20MA/2X4-20MA/24DC/-EP [DIN] |
| Unit | SST 4-wire (line/mains powered) safety isolator and splitter |
| Safety | exida certified IEC 61508:2010: SIL 3 capable in monitor mode where only the input circuit is part of the safety function; SIL 2 in single use |
| Input | 4-20 mA into 100 ohms with HART digital data |
| Output | Two isolated 4-20 mA channels into 600 ohms each, HART superimposed on channel A |
| Power | 24 V DC plus or minus 10%; 5 watts maximum for dual output |
| Option -EP | External power: outputs powered by an external source; only on 2X4-20mA output models; voltage limit 30 V DC maximum |
| Accuracy | Plus or minus 0.1% of span |
| Isolation | 500 Vrms between input, outputs, case and power; tested at 1500 Vrms for one minute |
| Response | 100 ms maximum to 99% of output |
| Stability | Plus or minus 0.2% of reading per year |
| Input overrange protection | 250% of full scale |
| Common mode rejection | Exceeds 95 dB at 60 Hz |
| Weight | SST splitter DC version 15 oz (425 g) |
| Adjustments | Front panel pots, span and zero plus or minus 2% |
| Ambient | -40 to +85 C operating; 5-95% RH non-condensing |
Among the numbers, the 100 ms response to 99% and the plus or minus 0.2% of reading per year stability are most relevant to safety engineers, since they feed into the process safety time and the proof-test interval. The splitter version draws up to 5 watts with both outputs, a modest load for a 24 V DC distribution.
How SST/4-20MA/2X4-20MA/24DC/-EP [DIN] differs from other SST and SSX variants
The SSX is the two-wire, loop-powered sibling and weighs 8 oz (227 g); the SST is mains or 24 V powered and the splitter version weighs 15 oz (425 g) in the DC version. The -EP option is only available on 2X4-20mA output models, like this one, and limits the voltage to 30 V DC.
Other SST options include -IZ250 for a 250 ohm input, -0HART for no HART pass-through, -2HART for HART on both channels, -RO for reverse outputs and -LMD for a loop maintenance diode; this code uses none of them.
Applications
Use it to feed a logic solver and a DCS from one safety transmitter, so that the BPCS and the SIS each have an isolated signal. Common in emergency shutdown systems for pressure, level and temperature transmitters at oil and gas facilities.
The splitter also eases maintenance: either output loop can be worked on without losing the signal on the other loop.
Selection notes for SST/4-20MA/2X4-20MA/24DC/-EP [DIN]
Verify that the external power source for -EP stays within the 30 V DC limit and can drive the 600 ohm load on each channel. Confirm the power supply is 24 V DC plus or minus 10% and capable of the 5 watts required for dual output.
Decide whether HART pass-through is needed on both channels; the default places HART on channel A.
Keep in mind that the HART pass-through on a splitter applies to channel A in the standard model, while HART on both channels needs the -2HART option, which is a different code. If your asset management package must reach the transmitter from both systems, discuss the option set with us before ordering.
Installation
Snap the aluminum DIN housing onto a 35 mm Top Hat rail, wire the input, the two outputs, the external power and the 24 V DC supply, and trim zero and span if needed using the front panel pots. A flange bracket is optional for high vibration.
After wiring, check each output with a calibrator against the input.
Proof test and maintenance
Follow the safety manual and FMEDA data for the proof-test interval. Inspect terminals, verify the isolation function, and test the response of both outputs to input steps.
Keep spare units under control with the same option set.
Supply of SST/4-20MA/2X4-20MA/24DC/-EP [DIN]
Please quote SST/4-20MA/2X4-20MA/24DC/-EP [DIN] in full and state whether FMEDA documentation is needed.
Seven Star LLC is an independent supplier serving Oman and the wider GCC and is not affiliated with the manufacturer; all names and part numbers are used only to identify the product being requested.
Documents and quotation
A datasheet for Moore Industries SST/4-20MA/2X4-20MA/24DC/-EP [DIN] can accompany our quotation. Send an RFQ with part number, quantity and delivery point.
Other Models in the SSX SST Range
Seven Star LLC supplies models from the SSX SST range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Moore Industries SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN] Isolator | Isolator & Barrier | View details |
| Moore Industries SST/4-20MA/2X4-20MA/24DC/-EP [DIN] Splitter | Isolator & Barrier | You are viewing this model |
Datasheets & Documents
- Datasheet Moore Industries SST/4-20MA/2X4-20MA/24DC/-EP [DIN] Splitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.
Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.
Moore Industries company profile
| Founded | 1968, North Hills, California, USA, by Leonard W. Moore |
|---|---|
| Headquarters | North Hills, California, since 1974 |
| Ownership | Privately owned (Moore Industries-International, Inc.) |
| First product | SCT signal converter |
| Product families | Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA) |
Milestones
- 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
- 1974: The company moves into its North Hills headquarters.
- 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.
Moore Industries product families on this page
The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:
- Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
- Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
- Signal isolators, repeaters and converters: the SIX
- PID controllers and backup stations: the 535 in 1/4 DIN format
Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.
Where Moore Industries instruments are used
These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.
Moore Industries products we list
Ordering Moore Industries instruments: what we need
Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.
Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.
Browse Moore Industries products by category: Temperature Instrumentation, Controllers & Data Acquisition, Isolator & Barrier.
FAQ
Questions about the Moore Industries SST/4-20MA/2X4-20MA/24DC/-EP [DIN]
Answers from our engineering team on installation, compatibility and integration.
01What does the -EP option do?
It uses external power so the outputs are powered by an external source; it is available only on 2X4-20mA output models and limits voltage to 30 V DC.
02What SIL level is the SST suitable for?
SIL 3 in monitor mode where only the input circuit is part of the safety function, and SIL 2 in single use.
03Does it pass HART?
Yes. HART data passes through, with HART on channel A on the standard dual model.
04What power does it need?
24 V DC plus or minus 10% for this code, with up to 5 watts for the dual-output model.
05How many outputs does it provide?
Two isolated 4-20 mA outputs, each into 600 ohms.

















![Moore Industries SST/4-20MA/2X4-20MA/24DC/-EP [DIN] Splitter Moore Industries SST/4-20MA/2X4-20MA/24DC/-EP [DIN] Splitter](https://omansevenstar.com/wp-content/uploads/2026/11/moore-industries-sst-4-20ma-2x4-20ma-24dc-ep-din-safety-isolator-splitter-external-power.webp)