Brand:

Pepperl+Fuchs NCB5-18GM40-N0-V1 M18 NAMUR Sensor with M12 Plug

Description

Pepperl+Fuchs NCB5-18GM40-N0-V1 with plug-in M12 connection

If the cable version of this sensor is awkward to swap in a congested junction box, the Pepperl+Fuchs NCB5-18GM40-N0-V1 is the answer: the same M18 x 1 stainless barrel, 5 mm flush NAMUR electronics and yellow switching LED, but terminated in an M12 x 1 connector plug instead of a fixed lead.

The NCB5-18GM40-N0-V1 is a 40 mm long, 18 mm diameter body with a rated operating distance of 5 mm and assured operating distance of 0 to 4.05 mm. It is supplied as a two-wire NAMUR device with 8.2 V nominal voltage, which the datasheet states as usable up to SIL 2 with MTTFd of 1880 years.

What the plug changes about the NCB5-18GM40-N0-V1

  • Connection type is a connector plug with M12 x 1 threading rather than a cable, so the sensor can be unscrewed without opening a terminal box.
  • Degree of protection is IP66 / IP67, the same ratings as the cable version.
  • MTTFd is 1880 years, against 2040 years for NCB5-18GM40-N0.
  • Switching state is indicated by a multihole yellow LED.
  • A mating NAMUR female cordset is chosen separately, which lets the length and cable jacket be matched to the route.

NCB5-18GM40-N0-V1 technical data table

Parameter Value
Part number NCB5-18GM40-N0-V1
Switching function Normally closed (NC), NAMUR
Rated operating distance sn 5 mm flush
Assured operating distance sa 0 to 4.05 mm
Reduction factors rAl 0.35, rCu 0.3, r304 0.74
Nominal voltage Uo 8.2 V, Ri approx. 1 kOhm
Switching frequency 0 to 400 Hz
Hysteresis 1 to 15 percent, typically 5 percent
Current min. 3 mA free, 1 mA or less detected
Short-circuit protection Yes
Indicator Multihole LED, yellow
SIL / MTTFd SIL 2 / 1880 a, TM 20 a, DC 0 percent
Ambient temperature -25 to 100 degrees C
Housing Stainless steel 1.4305 / AISI 303, PBT face
Protection IP66 / IP67
Connector M12 x 1
Length and diameter 40 mm and 18 mm

Typical duties for the NCB5-18GM40-N0-V1

The plug makes the NCB5-18GM40-N0-V1 well suited to skid-mounted equipment that is built, tested and shipped before being connected on site, for example chemical injection packages and metering skids for upstream oil facilities. It also suits pump rooms in desalination plants where the sensor on an actuator stem is occasionally replaced during shutdowns.

Because the electronics are NAMUR, the loop terminates in a barrier in a safe area, so the same sensor family can be fitted across hazardous-area zones. Typical targets are a steel cam, a valve stem flag or a rotating collar.

How NCB5-18GM40-N0-V1 differs from the cable and larger variants

The cable version NCB5-18GM40-N0 has the same 5 mm range, 400 Hz frequency and 1 to 15 percent hysteresis but a 2040 year MTTFd and a 2 m lead. The NCB2-12GM35-N0-V1 drops the range to 2 mm in an M12 barrel at 1000 Hz, and the NJ10-30GM-N-V1 raises it to 10 mm in an M30 barrel at 300 Hz.

Pick the NCB5-18GM40-N0-V1 when 5 mm is the correct gap for your cam and the connection will be replaced in the field.

Compatibility with isolators and cordsets

Use a barrier or switch amplifier rated for EN 60947-5-6 NAMUR sensors. For the related NJ10-30GM-N-V1 the datasheet assigns pin 1 to L+ and pin 2 to L-, and lists the V1-G-N-2M-PUR female M12 NAMUR cordset as an accessory; confirm the pinout in the NCB5-18GM40-N0-V1 datasheet before wiring. Check that the cordset is NAMUR rated, with blue jacket where required by your hazardous-area drawing.

Fitting and commissioning the NCB5-18GM40-N0-V1

Mount the sensor with two nuts in the bracket, keeping the target within 4.05 mm. Screw on the cordset hand tight, taking care not to cross-thread the M12 coupling. Check the yellow LED switches when the target arrives and release, and confirm the barrier output. Do not run the sensor above 100 degrees C ambient.

Care and spare strategy

Plug connections concentrate wear at the coupling nut, so inspect it for corrosion and dried seal. Keep at least one spare plug-in sensor on the shelf for critical valve position loops; the swap takes minutes and needs no rewiring.

Worked example: valve-position feedback with the NCB5-18GM40-N0-V1

Consider a quarter-turn ball valve actuator in a gas metering skid. Two sensors are fixed to a bracket either side of a steel flag on the indicator shaft. One NCB5-18GM40-N0-V1 proves open and the other proves closed. Each M12 plug leads through a NAMUR cordset to a barrier channel, so a cable fault shows up as an open or short circuit on the loop rather than as a silent wrong state.

The 5 mm rated distance leaves useful clearance around a flag moving through a few degrees of arc, and the 400 Hz switching frequency is far above anything a valve stem produces. Typical set-up uses a gap around 2 to 3 mm, comfortably inside the assured distance of 4.05 mm, which tolerates both the thermal growth of the bracket and the wear in the flag pivot.

When the plug-in feature matters most is during turnaround. The maintenance crew can swap a sensor without opening the field junction box, which keeps the box seal intact and avoids re-terminating intrinsically safe conductors. Record the cordset length and colour code on the loop sheet so the next technician reconnects the same polarity.

Electrical behaviour of the NCB5-18GM40-N0-V1 loop

NAMUR sensors behave like a variable resistor in series with a nominal 8.2 V source. When the target is far away, the sensor passes a minimum of 3 mA; when the target is in the sensing field, the current falls to 1 mA or less. The amplifier decides state by a threshold placed between those values, and most barrier channels also offer line fault detection for open and short circuits, so check the channel settings against the barrier datasheet when you choose it. The hysteresis of 1 to 15 percent, typically 5 percent, prevents chatter when a target rests near the switching point.

Ordering notes

Quote the full NCB5-18GM40-N0-V1 suffix including V1 so the plug version is supplied. Include quantity and delivery place in Oman or the GCC. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Documents and quotation

The datasheet for the NCB5-18GM40-N0-V1 is available with this listing. Please send an RFQ to Seven Star LLC stating the part number NCB5-18GM40-N0-V1, quantity and the cordset you intend to use.

Other Models in the Ncb Namur Range

Seven Star LLC supplies models from the Ncb Namur range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pepperl+Fuchs NCB5-18GM40-N0 M18 NAMUR Inductive Sensor 5 mmInductive Proximity SensorsView details
Pepperl+Fuchs NCB2-12GM35-N0 M12 NAMUR Inductive Sensor 2 mmInductive Proximity SensorsView details
Pepperl+Fuchs NCB5-18GM40-N0-V1 M18 NAMUR Sensor with M12 PlugInductive Proximity SensorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Pepperl+Fuchs NCB5-18GM40-N0-V1 M18 NAMUR Sensor with M12 Plug Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.

Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.

Pepperl+Fuchs company profile

Founded 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs
Headquarters Mannheim, Germany
Ownership Privately owned (Pepperl+Fuchs SE)
Origins Radio repair workshop that began making replacement transformers
Product families Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures

Milestones

  • 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
  • 1958: The first proximity switch is developed (some company sources say 1959).

Pepperl+Fuchs product families on this page

On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.

Where Pepperl+Fuchs equipment is used

Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.

Pepperl+Fuchs products we list

Family Examples
Isolator & Barrier HiD2030 SMART Transmitter Power Supply w…, KFD2-SR2-Ex2.W K-System Isolated Switch…, KFD2-UT2-Ex2 Universal Temperature Conve…
Industrial Computers Tab-Ex 05 DZ1 WWAN Hazardous Area Tablet, Smart-Ex® 03 DZ2 smartphone for Zone 2/2…
Inductive Proximity Sensors NJ2-12GK-SN NAMUR Inductive Sensor
Power Modules PS1000-A6-24.20 Power Supply 24 VDC 20 A
Photoelectric Sensors R101 Retro-Reflective Photoelectric Sensor
Laser Distance, LiDAR & Radar Sensors R2000 2-D LiDAR Laser Scanner

Ordering Pepperl+Fuchs parts: what we need

Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.

Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.

FAQ

Questions about the Pepperl+Fuchs NCB5-18GM40-N0-V1 M18 NAMUR Sensor

Answers from our engineering team on installation, compatibility and integration.

01How does the NCB5-18GM40-N0-V1 connect to the loop?
It has an M12 x 1 connector plug, so a NAMUR cordset is screwed on rather than wiring a fixed cable.
02What is the sensing range of this version?
Rated operating distance is 5 mm flush, with an assured range of 0 to 4.05 mm and 1 to 15 percent hysteresis.
03What is its MTTFd value?
The datasheet lists 1880 years with 20 years mission time and diagnostic coverage of 0 percent, usable up to SIL 2.
04Is the housing suitable for washdown?
Yes, stainless steel 1.4305 housing with IP66 / IP67 protection and operation from -25 to 100 degrees C.
05How do I request a quotation?
Send an RFQ to Seven Star LLC listing the part number NCB5-18GM40-N0-V1 and quantity.