Brand:

AMETEK 700-0005-018 Drexelbrook PVDF Flex Cable Probe

Description

A flexible element: AMETEK 700-0005-018

Not every tank lets you drop a rigid rod in from the top. Sludge pits, digesters, silos and tall slurry vessels often have a small nozzle, little headroom, and material that clings to anything it touches. AMETEK 700-0005-018 answers that with a 5/16 inch PVDF insulated flexible cable, the element the Drexelbrook datasheet names for coating liquids, slurries, granulars and interface, and for agitated service when it is anchored. Its SE code is 713.

Digesters and floating roofs: the application the datasheet calls out

The Universal IV datasheet singles out 700-0005-018 in its digester discussion, stating that it has many years of proven history there. In a sewage digester under a floating roof, the cable can either measure sludge level while ignoring heavy foam on the sensor, or be mounted to the roof to measure the bio-gas volume above the sludge. The Universal IV Pro model is described as the technology of first choice, because its Cote-Shield 45 degree phasing rejects coating build-up. The same datasheet notes equalization tanks, where manganese, iron and chlorine deposit heavily, as another natural home.

Key figures for 700-0005-018

Parameter Value
Part number 700-0005-018
Sensing element type Flexible RF cable probe
Construction 5/16 inch PVDF insulated flexible cable
Typical application Coating liquids, slurries, granulars and interface; agitated service when anchored
Maximum pressure at 100 F 1000 psi
Maximum pressure at 250 F 500 psi
Maximum temperature in table 250 F
Universal IV SE code 713
Datasheet use case Digesters and equalization tanks
Sensor length range (Universal IV) 1 inch to 800 feet, probe dependent
Capacitance range (Pro) 1 to 45,000 pF
Response time 350 msec nominal, 1 to 90 s damping
Approvals of Universal IV IS, XP, FM, FMc, ATEX, IECEx, CE

Data from the Drexelbrook probe table; lengths are made to order.

What flexibility buys you

  • Installs through narrow nozzles; no rigid rod length to clear.
  • PVDF insulation shrugs off most aqueous and many chemical process fluids.
  • Works with coating liquids when paired with Pro electronics, which use 45 degree phasing.
  • The datasheet expressly allows agitated service provided the cable is anchored at its tip.
  • Lengths range widely because the Universal IV sensor length spans 1 inch to 800 feet depending on the probe.

How 700-0005-018 differs from other Drexelbrook cables

Within the flexible family, 700-0005-018 is the general slurry and coating-liquid cable. Compare it with 700-0005-054, a thin 0.093 inch PFA cable rated 300 F, built for coating applications where you want weight and cost to be low and lengths up to 400 feet. Compare it with 700-0005-019, an urethane cable for coal, ores and other abrasive solids limited to 150 F and 5 psi. Compare it with 700-0005-085, a 0.185 inch FEP cable with integral ground for non-metallic vessels, 200 F and 200 psi. And compare it with 700-0205-078, a three-terminal PVDF cable with anchor and slack adjuster for granular materials. 700-0005-018 sits in the middle: 250 F, 500 psi, PVDF.

Temperature and pressure window

The table pairs 1000 psi at 100 F with 500 psi at 250 F. If your service is hotter, 700-0005-018 is the wrong choice and the 3/4 inch PTFE rod 700-0002-024 or the PFA cable 700-0005-054 should be reviewed. In vacuum or low-pressure silo service the pressure rating is rarely the limit; temperature and abrasion are.

Installation of 700-0005-018 in agitated or deep vessels

Anchor the lower end of 700-0005-018 with the supplied anchor method for the application, keep it away from the mixer blade path, and leave enough slack that the cable can rise and fall with product without kinking. For floating-roof digesters, fix the cable on the roof structure so it follows the roof movement as the manufacturer describes. Complete empty and full setpoints using the Universal IV keypad, then damp the output within 1 to 90 seconds if the surface is turbulent.

Maintenance

Cables see mechanical wear more than rods. Examine the PVDF cover for abrasion at points where it touches nozzles or structure, and replace the cable if the conductor is exposed. Because 700-xxxx-xxx probes are shared across Drexelbrook RF products, a cable that fits a legacy Universal III or RCT can be paired with new Universal IV electronics without changing the element.

Supplier note

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Give us the cable length, process fitting and the electronics model when you request 700-0005-018.

Practical advice for deep tanks with 700-0005-018

Cable probes reward careful planning. Measure the real distance from the nozzle to the lowest level you want to see, then add the length needed for the anchor. Because the Universal IV sensor length can extend to 800 feet for some elements, the actual limit for a given cable is a matter of the specific probe and electronics, so quote the length you need rather than assuming. In tall silos filling can create strong downward pull on the cable; anchoring prevents it from swinging into the wall, which would produce false capacitance. In wastewater service, schedule inspection of the cable during digester cleaning intervals and record the date so wear trends become visible.

Remember that 700-0005-018 is a sensing element only: the transmitter, the process connection and the weight or anchor are selected separately. A complete assembly is described by a Universal IV model number with the three-digit code 713 in the last block, followed by the length and connection details agreed at order. Clear specification of those details lets us match the spare to your installed unit and avoids repeating the quotation.

Documents and quotation

The Universal IV datasheet attached to this page includes the probe table with 700-0005-018 and the digester application notes. Send an RFQ containing part number 700-0005-018, quantity and required length, and we will confirm availability.

Other Models in the Drexelbrook Rf Probes Range

Seven Star LLC supplies models from the Drexelbrook Rf Probes range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
AMETEK 700-0001-022 Drexelbrook 3/8 in PTFE Level ProbeLevel ControllersView details
AMETEK 700-0005-054 Drexelbrook PFA Thin Cable ProbeLevel ControllersView details
AMETEK 700-1202-001 Drexelbrook 316L PEEK Rod ProbeLevel ControllersView details
AMETEK 700-0002-024 Drexelbrook 3/4 in PTFE High-Temp ProbeLevel ControllersView details
AMETEK 700-0005-018 Drexelbrook PVDF Flex Cable ProbeLevel ControllersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet AMETEK 700-0005-018 Drexelbrook PVDF Flex Cable Probe Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.

Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.

AMETEK company profile

Established 1930, USA, as American Machine and Metals; later renamed AMETEK
Headquarters Berwyn, Pennsylvania
Structure Two groups: Electronic Instruments (EIG) and Electromechanical (EMG)
Process brands Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex

Milestones

  • 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
  • Early 1960s: The company is renamed AMETEK.
  • 2021: AMETEK acquires Magnetrol.

AMETEK products we list

Product Type Typical use
888, 900, 930 Western Research sulfur recovery analysers Tail gas, air demand and H2S in sulfur pits on Claus units
931, 933, 9900RM/WM UV gas analysers H2S in natural gas and multi-component process streams
5000, 3050-OLV, 5100HD, 5100P Moisture analysers Water content in natural gas and process gases; the 5100 models use TDLAS
241CE II, Chanscope II / Model 13 Dew point analysers and testers Hydrocarbon and water dew point of natural gas
WDG 1200/1210, WDG-V, TM2000 Thermox oxygen analysers Combustion control on heaters and boilers, and trace oxygen
SPOT+, Cyclops L Land pyrometers Non-contact temperature of furnaces, kilns, tubes and hot metal
120HD, Ranarex, Drexelbrook RCT-1210 Portable analysers and level Hydrogen purity in generators, gas specific gravity, RF level measurement

Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.

Where AMETEK instruments are used

In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.

Ordering AMETEK products: what we need

Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.

Facts checked against AMETEK company history, October 2026.

FAQ

Questions about the AMETEK 700-0005-018 Drexelbrook PVDF Flex Cable

Answers from our engineering team on installation, compatibility and integration.

01Why is 700-0005-018 used in digesters?
The Universal IV datasheet states that 700-0005-018 has many years of proven history in digesters, where the flexible cable can ignore foam or measure bio-gas volume.
02What is the temperature limit of 700-0005-018?
The manufacturer table gives 250 F at 500 psi, and 1000 psi at 100 F.
03Does 700-0005-018 need to be anchored?
The datasheet lists it for agitated service when anchored, so fix the lower end and keep the cable away from mixers.
04How does 700-0005-018 compare with 700-0005-054?
700-0005-018 is a 5/16 inch PVDF cable at 250 F; 054 is a 0.093 inch PFA cable at 300 F with up to 400 ft insertion length.
05What do you need for an RFQ for 700-0005-018?
Send part number 700-0005-018 with quantity, cable length, process connection and electronics model.