Brand: AMETEK
AMETEK 700-0005-054 Drexelbrook PFA Thin Cable Probe
Description
AMETEK 700-0005-054 in one paragraph
AMETEK 700-0005-054 is the lightest sensing element in the Drexelbrook range: a PFA insulated flexible cable only 0.093 inch in outside diameter that the manufacturer says can be used in lengths up to 400 feet. A dedicated datasheet exists for continuous level transmitters built on the 700-5-54 series element, and its three key benefits are economy, easy installation and proven performance. The 3-digit code in the Universal IV selection table is 318.
Why a thin cable matters
The datasheet explains the installation advantage plainly: the lightweight element can be installed in any connection of 3/4 inch NPT or larger with only 10 inches of overhead clearance. Compare that with a rigid rod that needs its full length in free headroom above the vessel. For a 100 ft tall silo or a deep storage tank, 700-0005-054 can be coiled, lowered through the nozzle and fixed with a weight. The element can also be shortened in the field, which means one stocked length can serve several tanks.
Specifications of 700-0005-054 assemblies
| Parameter | Value |
|---|---|
| Part number | 700-0005-054 |
| Sensing element | 0.093 inch OD PFA insulated flexible cable |
| Maximum insertion length | 400 ft |
| Standard mounting | 3/4 inch NPT |
| Process pressure and temperature | 300 psi at 300 F (system datasheet) |
| Cooling extension | 6 inch required above 212 F (100 C) |
| Installation clearance | 10 inches overhead |
| Universal IV SE code | 318 |
| Typical systems | UP21010000-318-0, 508-45-25, UL21010000-318-0 |
| Wetted materials | 316L, TFE, PFA |
| Supply | 13 to 30 VDC, 2-wire, 4-20 mA HART |
| Accuracy | 0.25 percent of span (ranges 2 to 6) |
| Startup time | Less than 12 seconds |
| Remote cable | 100 ft maximum |
The dedicated datasheet lists the typical systems below; the cable part 700-0005-054 is the sensing element used in all three.
Choice of electronics with 700-0005-054
The datasheet shows three typical systems. UP21010000-318-0 is the Universal IV Pro for heavy coatings; 508-45-25 is the older Universal II for heavy coatings; and UL21010000-318-0 is the Universal IV Lite for light coatings. For the Lite model the span is reduced at lengths of 140 ft or less. Coating performance comes from the patented Cote-Shield circuitry, which lets the system ignore coatings that build up on the sensing element or vessel wall; the manufacturer says no maintenance is needed for that reason.
How 700-0005-054 differs from other flexible Drexelbrook elements
- Diameter 0.093 inch against 5/16 inch for 700-0005-018.
- Material PFA against PVDF; PFA is compatible with almost all process materials according to the datasheet.
- Temperature 300 F against 250 F for 018, with 300 psi at 300 F on the dedicated datasheet.
- Length up to 400 ft, set by the datasheet.
- Weight: light, with a range of weights available for the process connection, unlike the heavy-duty urethane cable 700-0005-019.
Note that the Universal IV selection table shows 500 psi at 300 F for code 318, while the dedicated datasheet shows 300 psi at 300 F for the typical systems. Use the system datasheet value when you quote a complete assembly and ask the manufacturer for confirmation if your design depends on it.
Temperature extension and pressure
A footnote in the datasheet says temperatures in excess of 212 F (100 C) require a 6 inch cooling extension to maintain the pressure rating. That matters for hot service: without the extension the rated pressure is not guaranteed.
Installation of 700-0005-054
Check the nozzle is at least 3/4 inch NPT, leave 10 inches of overhead clearance, choose the weight suited to your vessel, and feed the cable down gently to avoid kinks. Shorten the cable on site if needed, then recalibrate empty and full with the Universal IV keypad. Remote configuration up to 100 ft is available when the housing cannot sit at the nozzle.
Typical uses and maintenance
The very low weight and price per foot make 700-0005-054 popular for storage tanks, hoppers and sumps in utilities and process plants around Oman. Maintenance is minimal; examine the PFA cover at inspection and replace if damaged. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Electronics that pair with 700-0005-054
The Universal IV is a 2-wire, loop powered unit that runs on 13 to 30 VDC with a 4-20 mA output and HART. Load resistance can be up to 550 ohms at 24 VDC, and at least 250 ohms is needed for HART communication. Ambient temperature range is minus 40 C to 75 C, and process temperature capability is stated as minus 106 C to 815 C depending on the probe. Accuracy is 0.25 percent of span on ranges 2 to 6, response to level change is 350 msec nominal before damping, and supply voltage effect is at most 0.2 percent of full scale. Temperature effect is 0.5 percent per 100 F. Emission and surge protection comply with IEC 61000-4 parts 2, 3, 4, 6 and 8 and CISPR 11 Group I Class B. Approvals cited include intrinsically safe, explosion proof without an IS barrier, FM, FMc, ATEX, IECEx and CE. With 700-0005-054, the Pro model gives a capacitance range of 1 to 45,000 pF and the Lite model 20 to 7,000 pF, autoranging across six ranges.
Retrofit and upgrade path
The datasheet describes a retrofit kit for existing systems, model Unn1010000-R00, where nn can be P0, P2, P1, P3, L0 or L1 to match the old 409 electronics. It includes adapters for all possible connections to the probe, so you do not need to know the probe model number. This is relevant for 700-0005-054 because legacy installations in Oman refineries and water plants often hold old Universal III or RCT housings. Replacing only the housing and keeping the rod in the vessel saves the cost and downtime of vessel entry. Keep a note of the SE code and the insertion length for your asset records.
Documents and quotation
Two datasheets support 700-0005-054: the dedicated 700-5-54 series sheet and the Universal IV probe table. Send an RFQ with part number 700-0005-054, quantity and required length, and we will confirm availability.
Other Models in the Drexelbrook Rf Probes Range
Seven Star LLC supplies models from the Drexelbrook Rf Probes range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| AMETEK 700-0001-022 Drexelbrook 3/8 in PTFE Level Probe | Level Controllers | View details |
| AMETEK 700-0005-054 Drexelbrook PFA Thin Cable Probe | Level Controllers | You are viewing this model |
Datasheets & Documents
- Datasheet AMETEK 700-0005-054 Drexelbrook PFA Thin Cable Probe Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.
Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.
AMETEK company profile
| Established | 1930, USA, as American Machine and Metals; later renamed AMETEK |
|---|---|
| Headquarters | Berwyn, Pennsylvania |
| Structure | Two groups: Electronic Instruments (EIG) and Electromechanical (EMG) |
| Process brands | Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex |
Milestones
- 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
- Early 1960s: The company is renamed AMETEK.
- 2021: AMETEK acquires Magnetrol.
AMETEK products we list
| Product | Type | Typical use |
|---|---|---|
| 888, 900, 930 | Western Research sulfur recovery analysers | Tail gas, air demand and H2S in sulfur pits on Claus units |
| 931, 933, 9900RM/WM | UV gas analysers | H2S in natural gas and multi-component process streams |
| 5000, 3050-OLV, 5100HD, 5100P | Moisture analysers | Water content in natural gas and process gases; the 5100 models use TDLAS |
| 241CE II, Chanscope II / Model 13 | Dew point analysers and testers | Hydrocarbon and water dew point of natural gas |
| WDG 1200/1210, WDG-V, TM2000 | Thermox oxygen analysers | Combustion control on heaters and boilers, and trace oxygen |
| SPOT+, Cyclops L | Land pyrometers | Non-contact temperature of furnaces, kilns, tubes and hot metal |
| 120HD, Ranarex, Drexelbrook RCT-1210 | Portable analysers and level | Hydrogen purity in generators, gas specific gravity, RF level measurement |
Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.
Where AMETEK instruments are used
In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.
Ordering AMETEK products: what we need
Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.
Facts checked against AMETEK company history, October 2026.
Browse AMETEK products by category: Gas Analyzer Accessories, Gas Analyzer Systems, Liquid Analytical Accessories, Level Transmitter.
FAQ
Questions about the AMETEK 700-0005-054 Drexelbrook PFA Thin Cable Probe
Answers from our engineering team on installation, compatibility and integration.
01How long can 700-0005-054 be?
The dedicated datasheet states 700-0005-054 can be used in lengths up to 400 feet.
02What clearance does 700-0005-054 need for installation?
Only about 10 inches overhead in a connection of 3/4 inch NPT or larger.
03When is a cooling extension needed for 700-0005-054?
The datasheet says temperatures above 212 F (100 C) require a 6 inch cooling extension to keep the pressure rating.
04Which electronics suit 700-0005-054?
Typical systems are the Universal IV Pro UP21010000-318-0, Universal IV Lite UL21010000-318-0 and the older Universal II 508-45-25.
05Can 700-0005-054 be cut to length in the field?
Yes, the datasheet says the sensing element is easily shortened in the field.


















Reviews
There are no reviews yet.