Condumax CDP301 Portable Hydrocarbon Dew-Point Tester
Description
Michell CDP301 overview: portable manual hydrocarbon and water dew-point tester for natural gas
The Michell CDP301 is a field-portable, battery-powered chilled-mirror tester that lets an operator watch condensation form on a cooled mirror and record both the hydrocarbon dew point and the water dew point of natural gas. The manufacturer describes it as a modern successor to the manual Bureau of Mines style dew-point tester, with an integral camera that captures time-stamped still images and video of the mirror surface.
This page repeats the facts published by the manufacturer for Michell CDP301 so that engineers, maintenance planners and buyers can confirm the code before sending an enquiry. The photograph shows the Michell product line that the CDP301 code belongs to, taken from the manufacturer product page.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list CDP301 so that procurement teams can quote the exact code that appears in the manufacturer documentation.
Key features of CDP301
- Fundamental chilled-mirror principle with visual identification of water and hydrocarbon condensate
- High-definition colour display with split-screen view for hydrocarbon and water dew-point modes
- Automatic mirror cooling-rate control selectable to the ISO 6327 or ASTM D1142 test practice
- Self-contained rechargeable lithium-ion battery with up to 8 hours of operation
- ATEX, IECEx and cQPSus hazardous-area certification as standard
- Operating pressure up to 100 barg (1450 psig), accuracy of ±0.5 °C on the mirror measurement
CDP301 technical specifications
| Parameter | Value |
|---|---|
| Order code | CDP301 (parent code CDP301, configuration A) |
| Measuring technique | Chilled mirror, manual visual detection |
| Accuracy | ±0.5 °C (±0.9 °F) |
| Maximum measurement depression | Up to 65 °C (149 °F) delta T |
| Resolution | 0.1 °C, 0.1 °F |
| Sample flow | 0.25 to 0.5 Nl/min |
| Operating pressure | Up to 100 barg (1450 psig) |
| Sample supply pressure | 20 to 100 barg (290 to 1450 psig) |
| Pressure measurement accuracy | ±0.25 % of full scale |
| Enclosure | Cast LM25 alloy, IP64 (NEMA 4 equivalent) |
| Gas connections | 1/8 inch NPT |
| Operating environment | -30 to +50 °C, maximum 95 % relative humidity |
| Supplied with | Rucksack, wheeled hard case, cleaning kit, power supply and charger |
Values above are taken from the manufacturer datasheet and order-code sheet listed on this page. The manufacturer states that specifications can change as part of continuous development, so confirm the current revision when the CDP301 is part of a tender or a certified installation.
Typical applications of CDP301 in Oman and the GCC
Natural gas processing, transmission pipeline checking, sour natural gas service and validation of online hydrocarbon dew-point analyzers are the applications named by the manufacturer. In Oman and the GCC this makes the CDP301 a typical spot-check tool for gas plants, custody-transfer stations and pipeline terminals.
- Oil and gas: gas processing plants, wellsites, export pipelines and metering stations
- Utilities and power: turbine fuel gas, instrument air and compressed air systems
- Water and desalination: process air, gas generation and laboratory support
- Manufacturing and laboratories: calibration, electronics, pharmaceutical and industrial gas production
Dew point is the temperature at which water vapour in a gas begins to condense at a given pressure, so a lower dew point means drier gas. Pressure dew point is the value at line pressure and is the figure that matters for compressed air and process gas, while atmospheric dew point refers to the same gas expanded to ambient pressure and reads much lower. Moisture can also be expressed in ppmV, a pressure-corrected volume fraction, so always confirm the unit and the reference pressure on a specification.
Good sample handling decides the quality of any moisture or dew-point reading. Use stainless steel tubing, keep lines short, avoid dead legs and filter out particles and liquids before the sensor. Plastic or rubber tubing absorbs and releases water vapour and slows the response, particularly at low dew points, and ambient moisture can enter through poorly made fittings, so check for leaks after commissioning.
Selection and compatibility notes for CDP301
The CDP301 is a manual tester that needs an operator, while the Condumax II and CD603 are automatic online analyzers. Choose CDP301 when portability and visual confirmation matter; the CDP301-SG code adds Kalrez seals. Confirm the sample supply pressure range of 20 to 100 barg against your tapping point and plan a suitable sample system.
Many Michell codes are built from a parent code followed by option letters. When you ask for a quotation for CDP301, copy the complete code from the instrument label or from your purchase specification, including every letter after the parent code, and state the serial number if the unit replaces an installed one.
Before ordering, collect the data that avoids mistakes: the complete code and option letters, the serial number and year of any installed unit, the supply voltage, the hazardous-area certificate required by the site, the process pressure and temperature, the gas composition and the connection type. For spares from older installations, a photograph of the nameplate helps confirm the match, and it is useful to say whether the item replaces a failed device or is for a new installation.
Ask for the calibration certificate type your quality system needs, such as a traceable factory certificate or an accredited laboratory certificate where the manufacturer offers it, and keep it with the asset record so the next calibration date is visible during audits.
Installation and commissioning of CDP301
Data transfer and charging or replacement of the batteries must be carried out in a safe area, as stated by the manufacturer. Connect the sample through the 1/8 inch NPT gas input, keep the flow within 0.25 to 0.5 Nl/min and follow the manual for the cooling-rate setting.
Always read the current manufacturer manual before commissioning, check the hazardous-area certificate where one applies, verify the supply and signal wiring, and record the as-found settings so that the next service visit has a reference.
Gulf installations add heat, dust and humidity. Instruments mounted outdoors need shade or a suitable enclosure, cable glands that match the enclosure rating and sample lines that avoid condensation on cold desert nights. Compare the ambient temperature range in the table with the highest site temperature before choosing a mounting position.
Maintenance and calibration of CDP301
Clean the mirror with the supplied cleaning kit at intervals set by your procedure, keep the battery charged in a safe area and review stored images and logs. Return the tester for calibration according to your quality system.
Moisture and dew-point measurements drift only slowly when the sample is clean, so most problems seen on installations of this kind come from contaminated sample lines, leaking fittings, wrong flow or damaged cables rather than from the instrument itself. A planned calibration interval agreed with your quality system keeps the measurement traceable.
Related products and ordering notes for CDP301
The same manufacturer family includes sensors, transmitters, online hygrometers, chilled-mirror reference instruments, hydrocarbon dew-point analyzers, sampling systems and calibration equipment. Other Michell codes already listed on this site, such as the Easidew transmitters, the Promet EExd analyzer and the Condumax II, can be quoted together in a single RFQ.
CDP301 FAQ summary
Typical questions concern what the code means, which options apply and what to send with an enquiry. In short, it is a portable manual hydrocarbon and water dew-point tester for natural gas, and the figures in the table above come from the manufacturer documents. Questions that are not answered here can be sent with the RFQ.
Documents and quotation
The manufacturer datasheet for CDP301 is attached to this page where available. To request a quotation, send an RFQ with the part number CDP301, the quantity and your delivery location in Oman or the GCC, and we will reply with availability and lead time.
Datasheets & Documents
- Datasheet Condumax CDP301 Portable Hydrocarbon Dew-Point Tester Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Condumax CDP301 Portable Hydrocarbon Dew-Point
Answers from our engineering team on installation, compatibility and integration.
01What is CDP301?
CDP301 is a portable manual hydrocarbon and water dew-point tester for natural gas, as described in the manufacturer datasheet and order-code sheet.
02Is the CDP301 an automatic analyzer?
No. The CDP301 is a manual, visual dew-point tester operated by a person; the Condumax II and CD603 are the automatic online analyzers in the same family.
03How long does the CDP301 battery last?
The datasheet states up to 8 hours of life from a full charge, and a spare battery can be swapped in if required, with charging done in a safe area.
04Can Seven Star LLC supply CDP301 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for CDP301?
Send the part number CDP301, the quantity, the full option string or instrument serial number, any certificate needs and the delivery location so we can prepare an accurate quotation.