Brand: Moore Industries
Moore Industries IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP] Ex-Proof I/P
Description
Moore Industries IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP] overview
The Moore Industries IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP] is an explosion-proof, field-mount current-to-pressure transmitter from the Moore Industries IPX family. It converts a 4-20 mA input to a 3-15 psig pneumatic output from a 20 psi supply and includes the -FR1 coalescing filter, miniature supply regulator and pressure gauge.
In the model string, EXI is the explosion-proof (NEMA 4X and 7) housing with a 1/2-inch NPT entry, and the P suffix adds hardware for mounting on a 2-inch pipe, giving the EXIP designation. The housing is rugged extruded aluminum and can be installed in nearly any location.
The two-wire IPX accepts 4-20 mA or 10-50 mA and converts it to a proportional pneumatic output for controlling valves, actuators and other pneumatic devices. The IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP] is a suitable choice when the converter has to be placed next to the final element in a harsh, classified area.
The part number written as IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP] is the model string given in the manufacturer datasheet as a worked ordering example for the IPX family, so it describes one complete, orderable configuration rather than a loose product family. Every field of the string (unit, input, output, supply or power, option and housing) can be changed when a different configuration is needed, and the datasheet table lists the allowed choices. If your plant standard differs from this example, send the configuration you need with your RFQ and we will check it against the table.
Key features of the Moore Industries IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP]
- Explosion-proof and intrinsically safe options in an extruded aluminum housing designed for NEMA 4X, IP65 and NEMA 7 requirements.
- Insensitive to shock and vibration thanks to a high-technology sensor.
- RFI/EMI effects are negligible at 20-500 MHz.
- Mounts in any vertical or horizontal position; surface or 2-inch pipe mounting.
- -FR1 option: coalescing filter, miniature supply regulator and gauge reading psi (0-60) and bar (0-4).
- Standard and metric conduit entry versions are offered in the family.
Technical specifications for IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP]
| Parameter | Value |
|---|---|
| Model string | IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP] |
| Input | 4-20 mA into 280 ohms nominal (200 ohms for intrinsically safe units) |
| Output | 3-15 psig |
| Supply pressure | 20 psi |
| Accuracy | Less than 0.5% of span including linearity, hysteresis and repeatability |
| Step response | 0.3 seconds into 100 ml (6 cubic inches) at 90% of span |
| Supply pressure effect | Maximum 0.3% per 1.4 psig change (0.3% per 0.1 bar) |
| Air consumption | 0.1 SCFM (0.18 kg/hr) dead-ended |
| Air capacity | 1.4 SCFM |
| Ambient operating range | -40 to +85 degrees C (-40 to +185 degrees F) |
| Adjustments | Zero: multiturn screw, plus or minus 3% of span; span: multiturn potentiometer to 100% of output span |
| Weight | 1.8 kg (3 lb 15 oz) |
| Housing | EXI explosion-proof, NEMA 4X and 7, 1/2-inch NPT entry; P suffix for 2-inch pipe mounting |
| Certifications | FM explosion-proof Class I, Division 1, Groups A (conduits sealed within 18 inches), B, C, D [FMEXI]; CSA explosion-proof Class I, Division 1, Groups A, B, C, D and Class II and III, Groups E, F, G; ATEX Type N Ex N IIC T6 IP65 [EXI, EXIM]; TUV intrinsically safe EEx ia IIC T4/T5/T6 |
The values above come from the manufacturer datasheet for the IPX family. Specifications can depend on the option and housing chosen, so always read the matching page of the datasheet before you finalise a purchase specification, and keep the full model string on your purchase documents.
Typical applications in Oman and the GCC
Current-to-pressure converters sit between an electronic control system and a pneumatic device. Common uses in the region include:
- Oil and gas wellhead, pipeline and processing sites, where pneumatic control valves and actuators are driven from a DCS or PLC.
- Power and desalination plants, for dampers, steam and water control valves and other pneumatic final elements.
- Water and wastewater facilities, for pneumatic valves on dosing, aeration and distribution lines.
- Manufacturing plants that retrofit electronic control onto older pneumatic actuators and positioners.
Running a two-wire signal cable instead of long runs of instrument tubing reduces installation effort, and the converter can be placed next to the valve or actuator for a short, fast pneumatic connection.
Selection and compatibility notes
Certifications depend on the option and housing letters. The datasheet lists -ISE (TUV intrinsically safe), -NE (ATEX Type N, Moore inherent), -PTJ (pneumatic test jack) and -GA1 (installed output gauge) as options, and FMEXI as the FM-approved version of the EXI housing. Specify the approval you need in your RFQ so that the correct housing and option letters are quoted.
The EXIM housing has an M20 x 1.5 metric entry instead of 1/2-inch NPT. The IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP] uses the NPT housing.
Check the pneumatic side first. The output range (for example 3-15 psig, 0.2-1 bar or 20-100 kPa) must suit the actuator or positioner, and the supply pressure given in the model string must match the output range, because the datasheet states that the output must match the supply pressure to its right in the ordering table. Reverse-acting ranges such as 15-3 psig are available when the valve logic requires them.
Then check the electrical side: the loop must be able to drive the stated input impedance, and any hazardous-area certification you need must be present in the option field. Mounting style, conduit entry thread (NPT or metric) and whether pipe-mounting hardware is required are set by the housing designator at the end of the model string.
Questions to settle before ordering IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP]:
- What pneumatic output range and supply pressure does the actuator need?
- Is a direct or reverse output required?
- Is a filter/regulator or pressure gauge option required?
- Which conduit thread and mounting arrangement suit the site?
- Which hazardous-area approval is required, if any?
Installation and commissioning
Because the housing is explosion-proof, conduit sealing, entry-device selection and cover tightening must follow the rules of the applicable area classification and local code. Group A installations require conduits to be sealed within 18 inches, as noted in the datasheet certification list.
Mount the transmitter close to the pneumatic device it serves, supply it with clean, dry, regulated instrument air only, and connect the pneumatic output port to the actuator. The datasheet notes that the unit can be mounted in any position but should be calibrated in its final orientation, so do the zero and span adjustments after the unit is fixed in place.
Wire the two-wire 4-20 mA loop with the correct polarity, seal the conduit entry as required by the area classification, then apply a 4 mA signal and adjust zero, followed by 20 mA and adjust span. Repeat until both points are within tolerance, then check mid-range.
Maintenance and service life
Most field problems with I/P converters are caused by contaminated or wet supply air. Keep the supply filter and regulator serviced, drain moisture regularly and confirm the supply pressure still matches the model string. The datasheet describes an optional coalescing filter and regulator for this purpose.
At scheduled shutdowns, run a five-point calibration check against a reference pressure gauge and mA source. Replace the unit or send it for repair if it cannot be brought within the published accuracy.
Related products and ordering notes
Related Moore Industries current-to-pressure products on this site include the IPT2 transmitter. Other housings in the same family (DIN-rail, polymer field-mount, aluminum field-mount and explosion-proof) cover different environments, so tell us where the unit will be installed if you are unsure which one to quote.
State the complete model string, including options and housing, when you ask for a price, and mention whether a datasheet or certificate is required with the delivery.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model designations belong to their owners and are used here only to identify the equipment you are asking about.
Frequently asked questions in brief
- What does the IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP] do? It converts a 4-20 mA signal to a 3-15 psig pneumatic output in an explosion-proof aluminum housing with a filter/regulator.
- What does the P suffix mean on the IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP]? The datasheet states that adding P to the EXI or EXIM housing designation includes hardware for mounting on a 2-inch pipe.
- What air supply does the IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP] need? This configuration is specified for a 20 psi supply; the air must be instrument air only.
- Can the IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP] be used in hazardous areas? The family carries explosion-proof and intrinsically safe approvals according to option; confirm the exact certificate you need before ordering.
- How do I get a quotation for the IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP]? Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.
Documents and quotation
The manufacturer datasheet for the IPX family is available for download from this page, and it contains the full ordering table, dimensional drawings and wiring diagrams referred to above. To request a quotation, send an RFQ that includes the part number IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP], the quantity you need, the delivery location in Oman or the GCC and any special requirements such as certification or documentation. We will confirm availability and lead time and reply with a written offer. Please check the datasheet and your own hazardous-area and safety requirements before you place an order.
Datasheets & Documents
- Datasheet IPX Explosion-Proof Current-to-Pressure Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.
Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.
Moore Industries company profile
| Founded | 1968, North Hills, California, USA, by Leonard W. Moore |
|---|---|
| Headquarters | North Hills, California, since 1974 |
| Ownership | Privately owned (Moore Industries-International, Inc.) |
| First product | SCT signal converter |
| Product families | Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA) |
Milestones
- 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
- 1974: The company moves into its North Hills headquarters.
- 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.
Moore Industries product families on this page
The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:
- Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
- Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
- Signal isolators, repeaters and converters: the SIX
- PID controllers and backup stations: the 535 in 1/4 DIN format
Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.
Where Moore Industries instruments are used
These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.
Moore Industries products we list
Ordering Moore Industries instruments: what we need
Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.
Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.
Browse Moore Industries products by category: Temperature Instrumentation, Controllers & Data Acquisition, Isolator & Barrier.
FAQ
Questions about the Moore Industries IPX/4-20MA/3-15PSIG/20PSI/-FR1
Answers from our engineering team on installation, compatibility and integration.
01What does the {pn} do?
It converts a 4-20 mA signal to a 3-15 psig pneumatic output in an explosion-proof aluminum housing with a filter/regulator.
02What does the P suffix mean on the {pn}?
The datasheet states that adding P to the EXI or EXIM housing designation includes hardware for mounting on a 2-inch pipe.
03What air supply does the {pn} need?
This configuration is specified for a 20 psi supply; the air must be instrument air only.
04Can the {pn} be used in hazardous areas?
The family carries explosion-proof and intrinsically safe approvals according to option; confirm the exact certificate you need before ordering.
05How do I get a quotation for the {pn}?
Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.

















![Moore Industries IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP] Ex-Proof I/P Moore Industries IPX/4-20MA/3-15PSIG/20PSI/-FR1 [EXIP] Ex-Proof I/P](https://omansevenstar.com/wp-content/uploads/2026/11/moore-industries-ipx-4-20ma-3-15psig-explosion-proof-ip.webp)
Reviews