- Automation & ControlView all 2,718 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Pepperl+Fuchs
Pepperl+Fuchs KFD2-UT2-Ex1-1 Universal Temperature Converter
Description
Pepperl+Fuchs KFD2-UT2-Ex1-1 overview
The Pepperl+Fuchs KFD2-UT2-Ex1-1 is a universal temperature converter in the K-System of Pepperl+Fuchs. It converts the signal of a resistance thermometer, a thermocouple or a potentiometer, or a millivolt source, to a proportional output voltage of 0 to 5 V or 1 to 5 V. A removable terminal block called K-CJC-** is available as an accessory for internal cold junction compensation of thermocouples, while an external reference is also possible.
A fault is shown by LEDs and by a separate collective error message output. The module is configured with the PACTware software through a programming socket, and the datasheet released on 3 January 2023 states SIL 2. Measuring types cover 2-, 3- and 4-wire RTD connections with sensor breakage and short-circuit monitoring, which makes the KFD2-UT2-Ex1-1 flexible enough to serve as a standard temperature interface in many hazardous-area cabinets.
Key features of the Pepperl+Fuchs KFD2-UT2-Ex1-1
- Universal input for RTD, thermocouple, potentiometer and voltage signals
- RTD types Pt10, Pt50, Pt100, Pt500, Pt1000, Cu10, Cu50, Cu100 and Ni100 plus GOST versions
- Thermocouple types B, E, J, K, N, R, S, T, L, TXK, TXKH and TXA with internal or external cold junction compensation
- Output 0 to 5 V or 1 to 5 V with fault signals downscale and upscale
- Configuration through PACTware and a programming socket
- SIL 2 according to IEC/EN 61508; 20 to 30 V DC supply with up to 0.64 W power
- Fault indication output and Power Rail collective error message
- 20 mm wide housing type B2, IP20, minus 20 to 60 degrees C
KFD2-UT2-Ex1-1 technical specifications
The values below are taken from the manufacturer datasheet of the KFD2-UT2-Ex1-1, release date 2023-01-03. Always confirm the current datasheet and the certificates before final engineering.
| Parameter | Value |
|---|---|
| Model | KFD2-UT2-Ex1-1, Universal Temperature Converter, 1-channel isolated barrier |
| Signal type | Analog input |
| Safety Integrity Level | SIL 2 |
| Rated supply voltage | 20 to 30 V DC (terminals 14+, 15- or Power Rail) |
| Power dissipation / consumption | Up to 0.64 W |
| Input terminals | 1, 2, 3, 4 (field side) |
| RTD types | Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751); GOST versions; Cu10, Cu50, Cu100; Ni100 (DIN 43760) |
| RTD measuring current / lead resistance | Approx. 200 microamperes / up to 50 ohm per line |
| Thermocouples | Types B, E, J, K, N, R, S, T (IEC 584-1), L (DIN 43710), TXK, TXKH, TXA |
| Potentiometer | 0 to 20 kilohm (2-wire); 0.8 to 20 kilohm (3-wire) |
| Voltage input | Selectable within minus 100 to 100 mV; input resistance at least 1 megohm |
| Output | 0 to 5 V or 1 to 5 V; output resistance up to 5 ohm; load at least 10 kilohm; terminals 7-, 8+ |
| Fault signal | Downscale 0 V or 0.5 V; upscale 5.375 V |
| Deviation after calibration, Pt100 | Plus or minus (0.06 percent of measured value in K plus 0.1 K), 4-wire |
| Reaction time (worst case) | Millivolt 1 s; thermocouple with CJC 1.1 s; 3- or 4-wire RTD 920 ms; 2-wire RTD 800 ms; potentiometer 2.05 s |
| Hazardous-area marking | (1)G [Ex ia Ga] IIC, (1)D [Ex ia Da] IIIC, (M1) [Ex ia Ma] I; certificate CESI 04 ATEX 143 |
| Input Ex ia values | Uo 9 V, Io 22 mA, Po 50 mW |
| Zone 2 certificate | TUV 02 ATEX 1797 X, marking Ex nA II T4 |
| Ambient temperature | Minus 20 to 60 degrees C |
| Dimensions / mass | 20 x 119 x 115 mm (W x H x D), housing type B2 / approx. 130 g |
| Degree of protection / mounting | IP20, screw terminals / 35 mm DIN rail |
The datasheet lists accuracy and temperature influence for each sensor type separately. Use those values, plus the cold junction error for thermocouples, when you calculate the loop error budget.
Typical applications in oil and gas, utilities, water and manufacturing
Temperature is the most common measurement in refineries, gas processing, power generation and desalination, and many sensors sit in Zone 1 or Zone 2 areas near furnaces, reactors, heat exchangers and turbine casings. The KFD2-UT2-Ex1-1 takes the raw sensor signal from RTDs or thermocouples in the hazardous area, isolates it, and presents a scaled voltage to the control system in the safe area.
In utilities, water plants and manufacturing across Oman and the GCC, the same converter handles bearing and winding temperatures on large motors, process temperatures in chemical dosing, and flue gas temperatures on boilers. Using one converter type for many sensor types keeps the spare parts list short, and PACTware configuration lets technicians set range, sensor type and fault behaviour without opening the cabinet wiring.
Because the KFD2-UT2-Ex1-1 accepts almost every industrial temperature sensor, it is also used as a spare that covers several loop types, which is useful for remote sites where a spare must match whatever sensor failed.
Selection and compatibility notes for KFD2-UT2-Ex1-1
Confirm that the control system input accepts a 0 to 5 V or 1 to 5 V signal, because the KFD2-UT2-Ex1-1 has a voltage output and not a 4 to 20 mA output. Then check the sensor type, the number of wires and the lead resistance, which must stay within 50 ohm per line, and choose internal or external cold junction compensation if you use thermocouples.
Check the intrinsic safety data of the sensor circuit as well. The input values given in the datasheet are low-energy values suited to passive sensors, so simple apparatus such as RTDs and thermocouples is normally easy to assess. If you need a 4 to 20 mA output or a different configuration method, send us your loop data and we will propose a matching module instead of the KFD2-UT2-Ex1-1.
Installation and commissioning of the KFD2-UT2-Ex1-1
Before mounting the KFD2-UT2-Ex1-1, confirm the field device and cable parameters against the entity values in the datasheet and the certificate, and decide whether the module will be powered from a Power Rail or from its own supply terminals. Mount it on a 35 mm DIN rail in a clean, ventilated cabinet in the safe area, keep hazardous-area and safe-area wiring physically separated and labelled, and respect the spacing and marking required by your site rules for intrinsically safe circuits. Order the K-CJC-** removable terminal block together with the converter if you want internal cold junction compensation for thermocouples, and keep a PACTware cable ready for configuration of the KFD2-UT2-Ex1-1.
Wire the KFD2-UT2-Ex1-1 only to the terminal assignment printed in the wiring diagram, tighten the screws and check that no strands are left outside the clamp. After applying the supply, check the power indication, then simulate the field signal and prove the complete loop from field to control system before the plant is handed over. Record the as-found readings so that later loop checks of the KFD2-UT2-Ex1-1 can be compared with the commissioning values.
Maintenance and service life
The KFD2-UT2-Ex1-1 has no serviceable parts, so maintenance is mostly inspection. During planned shutdowns, check terminals for looseness and corrosion, verify the supply voltage at the module, and repeat the loop check that was recorded at commissioning. In coastal and humid locations such as Muscat, Sohar and Duqm, a clean, dry and sealed cabinet greatly extends the life of any electronic interface. Keep the PACTware configuration file of each KFD2-UT2-Ex1-1 with the loop folder so that a replacement module can be programmed to the same range quickly.
If a loop drifts out of tolerance or the unit shows no power indication with a healthy supply, replace the module instead of attempting a repair, and keep the replacement documentation in the loop folder. Certified intrinsically safe equipment must not be modified, and any change to cabling, load or field device should be re-assessed against the KFD2-UT2-Ex1-1 entity parameters before it returns to service.
Related products and ordering notes
Customers who ask for the KFD2-UT2-Ex1-1 often need neighbouring models or accessories from the same system, such as other universal temperature converters of the KFD2-UT family, the K-CJC removable cold junction terminal block, the Power Rail and PACTware configuration cables. If you are standardising a cabinet on one family, send us the loop list and we can quote the matching modules together.
When you send an enquiry for the KFD2-UT2-Ex1-1, quote the full part number exactly as printed on the nameplate, the quantity and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the exact variant you need. We can arrange a quotation with delivery to Oman and across the GCC.
Frequently asked questions about KFD2-UT2-Ex1-1
The KFD2-UT2-Ex1-1 is a SIL 2 universal temperature converter for RTD, thermocouple, potentiometer and millivolt inputs with a 0 to 5 V or 1 to 5 V output, PACTware configuration and a collective error message.
Documents and quotation
A copy of the manufacturer datasheet for the KFD2-UT2-Ex1-1 is attached to this page for your engineering review. To request a quotation, send the RFQ with the part number KFD2-UT2-Ex1-1, the quantity, the delivery location and any certification or documentation requirements, and we will reply with availability and lead time. Please check the specification against your loop or system requirements before ordering.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with Pepperl+Fuchs. Product names and part numbers are used only to identify the item you ask for.
Other Models in the K System Range
Seven Star LLC supplies models from the K System range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pepperl+Fuchs KFD2-STC4-Ex1 SMART Transmitter Power Supply | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-STC4-Ex1.2O SMART Transmitter Supply, 2 Outputs | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-CD-Ex1.32 Current Driver for I/P Converters | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-CD-Ex1.32-13 Voltage Driver, 4-20 mA to 0-10 V | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-UT2-Ex1-1 Universal Temperature Converter | Isolator & Barrier | You are viewing this model |
Datasheets & Documents
- Datasheet KFD2-UT2-Ex1-1 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KFD2-UT2-Ex1-1 Universal Temperature
Answers from our engineering team on installation, compatibility and integration.
01Which sensors can the KFD2-UT2-Ex1-1 read?
It accepts RTDs such as Pt100, thermocouple types B, E, J, K, N, R, S, T, L, TXK, TXKH and TXA, potentiometers and millivolt signals.
02What is the output signal?
The output is a voltage of 0 to 5 V or 1 to 5 V, with fault signals at 0 V or 0.5 V downscale and 5.375 V upscale.
03How is the KFD2-UT2-Ex1-1 configured?
It is configured with the PACTware software through the programming socket at the front, and a programming cable provides galvanic isolation.
04Does it support cold junction compensation?
Yes, both external and internal compensation are supported, and the K-CJC-** removable terminal block is the accessory for internal compensation.
05How do I order the KFD2-UT2-Ex1-1?
Send an RFQ with the part number KFD2-UT2-Ex1-1, the quantity and the delivery location in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.


















Reviews