Pepperl+Fuchs KFD2-CD-Ex1.32 Current Driver for I/P Converters
Description
Pepperl+Fuchs KFD2-CD-Ex1.32 overview
The Pepperl+Fuchs KFD2-CD-Ex1.32 is a one-channel current driver from the K-System of Pepperl+Fuchs. It drives I/P converters, electrical valves and positioners in a hazardous area, taking a current signal from the control side and providing an isolated current output on the field side. The datasheet released on 16 December 2021 describes a current limit circuit in series with terminal 9 that protects the device from damage.
The maximum voltage drop at the input is 4 V DC, so several devices can be connected in series to create multiple galvanically isolated outputs from one signal, which is known as signal duplication. The open circuit voltage at terminals 1 and 2 is 24 V DC within the permitted supply range, and the maximum load that can be applied is 850 ohm. It is a 20 mm wide type B1 housing for DIN rail mounting.
Key features of the Pepperl+Fuchs KFD2-CD-Ex1.32
- One-channel isolated current driver for I/P converters, electrical valves and positioners
- Current input and current output of 0 to 20 mA, with a deviation below 0.1 percent of full scale
- Voltage drop at the input of approximately 4 V at 20 mA, which permits signal duplication
- Current limit circuit on terminal 9 protects the device
- Maximum load 850 ohm and output voltage of 17 V at 20 mA
- SIL 2 according to IEC/EN 61508; supply 20 to 35 V DC from Power Rail or terminals 7 and 8
- Marking [Ex ia Ga] IIC, [Ex ia Da] IIIC and [Ex ia Ma] I
- 20 mm wide housing type B1, IP20, minus 20 to 60 degrees C
KFD2-CD-Ex1.32 technical specifications
The values below are taken from the manufacturer datasheet of the KFD2-CD-Ex1.32, release date 2021-12-16. Always confirm the current datasheet and the certificates before final engineering.
| Parameter | Value |
|---|---|
| Model | KFD2-CD-Ex1.32, Current Driver, 1-channel isolated barrier |
| Signal type | Analog output |
| Safety Integrity Level | SIL 2 |
| Rated supply voltage | 20 to 35 V DC (Power Rail or terminals 7+, 😎 |
| Rated current / power dissipation | Up to 50 mA / 1.4 W |
| Input (control side) | Terminals 9+, 10-, 11+; transmission range 0 to 20 mA; limit up to 40 mA |
| Voltage drop at input | Approx. 4 V at 20 mA |
| Input current | Up to 100 microamperes up to 50 degrees C at 10 V |
| Output (field side) | Terminals 1+, 2-; current 0 to 20 mA; voltage 17 V at 20 mA |
| Output resistance | Up to 3 ohm |
| Deviation at 20 degrees C | Below 0.1 percent of full scale including non-linearity and hysteresis |
| Influence of ambient temperature | Up to 0.01 percent per K |
| Rise time | Below 10 ms |
| Isolation | Input to supply: functional insulation, 50 V AC |
| Hazardous-area marking | (1)G [Ex ia Ga] IIC, (1)D [Ex ia Da] IIIC, (M1) [Ex ia Ma] I |
| EU-type examination certificate | BAS 02 ATEX 7203 X |
| Zone 2 certificate | TUV 99 ATEX 1499 X, marking Ex nA II T4 |
| IECEx | IECEx BAS 05.0041X; IECEx CML 19.0051X |
| Ambient temperature | Minus 20 to 60 degrees C |
| Dimensions / mass | 20 x 107 x 115 mm (W x H x D), housing type B1 / approx. 100 g |
| Degree of protection / mounting | IP20, screw terminals / 35 mm DIN rail |
Specific entity values for the output terminals are given in the datasheet and certificate. Compare them with the input data and cable parameters of the I/P converter or positioner you will connect.
Typical applications in oil and gas, utilities, water and manufacturing
Control valves, I/P converters and electropneumatic positioners are the final elements of most process loops in oil and gas, power and water plants, and many of them sit in Zone 1 or Zone 2 areas. The KFD2-CD-Ex1.32 delivers the control signal from the safe area to such devices through an intrinsically safe circuit, so the plant can keep a standard analog output card while the field circuit stays safe.
Typical uses in Oman and the wider GCC include flow and pressure control valves on pipelines, anti-surge and recycle valves on compressor trains, and dosing or level control in water treatment works. Because the module is a galvanic isolator, ground loops between the control room and a distant field device are also avoided, which can improve signal quality on long cable runs.
Selection and compatibility notes for KFD2-CD-Ex1.32
Compare the load of the field device with the output capability of the KFD2-CD-Ex1.32. Positioners and I/P converters differ in their input resistance and operating voltage, and the datasheet gives the maximum load and available voltage at 20 mA. The control-side input must also be able to drive the module, which presents a voltage drop in series with the loop.
Decide whether you need HART signals to pass through. Where an asset management system communicates with smart positioners, the signal path must support bi-directional digital communication; where the loop carries a plain analog signal, a simpler driver may be sufficient. Share the loop data with us if you are unsure which variant of the KFD2-CD-Ex1.32 family suits the device.
Installation and commissioning of the KFD2-CD-Ex1.32
Before mounting the KFD2-CD-Ex1.32, confirm the field device and cable parameters against the entity values in the datasheet and the certificate, and decide whether the module will be powered from a Power Rail or from its own supply terminals. Mount it on a 35 mm DIN rail in a clean, ventilated cabinet in the safe area, keep hazardous-area and safe-area wiring physically separated and labelled, and respect the spacing and marking required by your site rules for intrinsically safe circuits. Check the polarity of terminals 9, 10 and 11 against the control system output before the first power-up, because the current limit circuit protects the KFD2-CD-Ex1.32 but a wrong connection will still prevent correct operation.
Wire the KFD2-CD-Ex1.32 only to the terminal assignment printed in the wiring diagram, tighten the screws and check that no strands are left outside the clamp. After applying the supply, check the power indication, then simulate the field signal and prove the complete loop from field to control system before the plant is handed over. Record the as-found readings so that later loop checks of the KFD2-CD-Ex1.32 can be compared with the commissioning values.
Maintenance and service life
The KFD2-CD-Ex1.32 has no serviceable parts, so maintenance is mostly inspection. During planned shutdowns, check terminals for looseness and corrosion, verify the supply voltage at the module, and repeat the loop check that was recorded at commissioning. In coastal and humid locations such as Muscat, Sohar and Duqm, a clean, dry and sealed cabinet greatly extends the life of any electronic interface. When troubleshooting a valve that does not move, measure the loop current at the control side and at terminals 1 and 2 to see whether the KFD2-CD-Ex1.32 or the field device is responsible.
If a loop drifts out of tolerance or the unit shows no power indication with a healthy supply, replace the module instead of attempting a repair, and keep the replacement documentation in the loop folder. Certified intrinsically safe equipment must not be modified, and any change to cabling, load or field device should be re-assessed against the KFD2-CD-Ex1.32 entity parameters before it returns to service.
Related products and ordering notes
Customers who ask for the KFD2-CD-Ex1.32 often need neighbouring models or accessories from the same system, such as other K-System current and voltage drivers, SMART current drivers, the Power Rail and power feed modules, and matching KFD2 transmitter power supplies. If you are standardising a cabinet on one family, send us the loop list and we can quote the matching modules together.
When you send an enquiry for the KFD2-CD-Ex1.32, quote the full part number exactly as printed on the nameplate, the quantity and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the exact variant you need. We can arrange a quotation with delivery to Oman and across the GCC.
Frequently asked questions about KFD2-CD-Ex1.32
The KFD2-CD-Ex1.32 is a SIL 2 current driver for I/P converters and positioners with a 0 to 20 mA output, a 4 V input voltage drop for signal duplication and an 850 ohm maximum load.
Documents and quotation
A copy of the manufacturer datasheet for the KFD2-CD-Ex1.32 is attached to this page for your engineering review. To request a quotation, send the RFQ with the part number KFD2-CD-Ex1.32, the quantity, the delivery location and any certification or documentation requirements, and we will reply with availability and lead time. Please check the specification against your loop or system requirements before ordering.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with Pepperl+Fuchs. Product names and part numbers are used only to identify the item you ask for.
Other Models in the K System Range
Seven Star LLC supplies models from the K System range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pepperl+Fuchs KFD2-STC4-Ex1 SMART Transmitter Power Supply | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-STC4-Ex1.2O SMART Transmitter Supply, 2 Outputs | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-CD-Ex1.32 Current Driver for I/P Converters | Isolator & Barrier | You are viewing this model |
Datasheets & Documents
- Datasheet KFD2-CD-Ex1.32 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KFD2-CD-Ex1.32 Current Driver for I/P
Answers from our engineering team on installation, compatibility and integration.
01What does the KFD2-CD-Ex1.32 drive?
It drives I/P converters, electrical valves and positioners in a hazardous area from a current signal in the safe area.
02What is the maximum load?
The datasheet states a maximum load of 850 ohm, with an output voltage of 17 V at 20 mA.
03Can several drivers share one signal?
Yes. The input voltage drop is only about 4 V at 20 mA, so several devices can be connected in series to duplicate the signal with galvanic isolation.
04What is the supply range of the KFD2-CD-Ex1.32?
It operates from 20 to 35 V DC through the Power Rail or terminals 7+ and 8-, with a power dissipation of 1.4 W.
05How do I order the KFD2-CD-Ex1.32?
Send an RFQ with the part number KFD2-CD-Ex1.32, the quantity and the delivery location in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.