Brand:

Beamex 8075644 Battery Pack MC6-Ex, NiMH RB-796-Ex

Description

Overview of Beamex MC6-Ex NiMH battery pack Beamex 8075644

The Beamex 8075644 is the rechargeable nickel metal hydride battery pack, type RB-796-Ex, for the intrinsically safe MC6-Ex calibrator. Capacity is 4200 mAh at 9.6 V.

Keeping a spare pack on the shelf avoids losing a classified-area calibrator while the first pack is being charged.

This page describes Beamex MC6-Ex NiMH battery pack for buyers who need the exact part number Beamex 8075644. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the data below is taken from the manufacturer published product pages and brochures.

Key features of 8075644

  • Order code: 8075644.
  • Battery chemistry: Rechargeable NiMH.
  • Pack type: RB-796-Ex.
  • Capacity: 4200 mAh.
  • Voltage: 9.6 V.
  • Fits: MC6-Ex calibrator.
  • Typical operation time in MC6-Ex: 4 to 8 hours.

Technical specifications for 8075644

Order code 8075644
Battery chemistry Rechargeable NiMH
Pack type RB-796-Ex
Capacity 4200 mAh
Voltage 9.6 V
Fits MC6-Ex calibrator
Typical operation time in MC6-Ex 4 to 8 hours
Charging time in MC6-Ex 10 hours from 0 to 100 percent at 0 to 30 degrees C

All values above come from the manufacturer documentation and may change with later revisions. Please quote 8075644 when you need the matching datasheet or a confirmation of the current revision.

Typical applications in Oman and the GCC

Battery packs are the part of a portable calibrator that ages first. Plants in Oman and the GCC that run calibrators daily for turnarounds, shutdown checks and routine rounds see capacity fall after repeated charge cycles, and a fresh pack restores full working time between charges.

Maintenance contractors working on oil and gas sites, utilities, desalination and manufacturing lines keep spare packs in the kit so that a flat battery never stops a loop check or a documentation run.

The part is relevant wherever the related calibration equipment is used: oil and gas, utilities, water, process manufacturing and calibration service providers in Oman and the wider GCC.

Equipment used in Oman and the wider GCC faces high ambient temperatures, dust and coastal humidity. Keep instruments and accessories out of direct sun, avoid leaving them in closed vehicles, and allow cold equipment to acclimatise before use when moving from an air-conditioned room to an outdoor unit. Cap connectors and threads when they are not in use so that sand and moisture stay out.

Selection and compatibility notes for 8075644

This part affects intrinsic safety. The manufacturer requires the serial number of the calibrator when it is ordered as a spare part, so that the replacement is traceable.

The pack must only be charged with the BC15-Ex charger (8075784) and must not be charged in a hazardous area.

Before ordering 8075644, confirm the model and, where relevant, the serial number or option code of the instrument it will serve. Confirm voltage, plug type, thread type or pressure rating as applicable, and check the manufacturer documentation for the firmware or hardware revision of the equipment.

If an item looks similar but carries a different part number, do not assume interchangeability. A short note of the calibrator model and application lets us confirm the match for 8075644 before it is supplied.

Installation and commissioning of 8075644

Switch the calibrator off and disconnect the charger and all test leads before opening the battery compartment. Follow the replacement procedure in the calibrator user manual, keep the connector orientation exactly as found, and refit the cover before switching on. After fitting 8075644, charge the pack fully with the matching charger before relying on it in the field.

Reset the date and time if the calibrator asks for it, and confirm that the battery indicator reads correctly. Dispose of the old pack through a battery recycling channel in line with local regulations.

Maintenance and care

Store spare battery packs partly charged in a cool, dry place and charge them before use. Avoid leaving a pack discharged for a long time, and do not charge outside the temperature limits given in the calibrator specification. Replace the pack when operating time becomes noticeably shorter than expected.

Use only the matching charger listed for the calibrator, and keep the contacts clean. Record the installation date of 8075644 so that replacement can be planned.

Calibration is only as useful as its records. Keep a log of serial numbers, certificate dates, replacement parts and any faults, and store the manufacturer documents with the equipment. This makes audits easier, helps predict when spares will be needed, and shortens the time needed to prepare a purchase request when a part has to be replaced at short notice.

Related products and ordering notes for 8075644

Related items include the matching power supply and power cord, a protective case and spare test leads. The calibrator brochure and the manufacturer webshop list each accessory by part number.

Hard-to-find and discontinued spare parts are a daily topic for maintenance planners in oil, gas, power and water facilities. When a plant standardises on one calibrator family, a small stock of the exact spares is far cheaper than a day of lost production, and an early enquiry gives the supplier time to confirm availability and shipping options to Oman and neighbouring countries.

Please note that Seven Star LLC prepares each quotation for 8075644 against the exact part number, so a request that quotes the number and the quantity is answered faster than a general description.

The part number 8075644 should be quoted exactly as printed in this page, because accessories and spares with similar descriptions often differ by one digit.

Frequently asked questions about 8075644

  • Which model does 8075644 fit? It is the battery pack for the MC6-Ex intrinsically safe calibrator.
  • Why is a serial number needed to order it? Replacement of components that affect intrinsic safety must use traceable parts, so the manufacturer asks for the calibrator serial number.
  • Which charger may be used? Only the BC15-Ex charger, and charging must take place outside the hazardous area.
  • What is the capacity? 4200 mAh at 9.6 V, pack type RB-796-Ex, according to the manufacturer documentation for 8075644.
  • How long does a charge last in use? About 4 to 8 hours depending on usage, according to the MC6-Ex brochure.

Documents and quotation

The official Beamex MC6-Ex User Manual is attached to this page as a PDF. Its battery sections cover the intrinsically safe battery pack of the MC6-Ex, the BC15-Ex charger and the rules for charging outside the hazardous area. Quote order code 8075644 in your request and we will confirm compatibility with your unit in a written quotation.

Datasheets & Documents
  • PDF Datasheet Beamex MC6-Ex User Manual (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 8075644 Battery Pack MC6-Ex, NiMH RB-796-Ex

Answers from our engineering team on installation, compatibility and integration.

01Which model does 8075644 fit?
It is the battery pack for the MC6-Ex intrinsically safe calibrator.
02Why is a serial number needed to order it?
Replacement of components that affect intrinsic safety must use traceable parts, so the manufacturer asks for the calibrator serial number.
03Which charger may be used?
Only the BC15-Ex charger, and charging must take place outside the hazardous area.
04What is the capacity?
4200 mAh at 9.6 V, pack type RB-796-Ex, according to the manufacturer documentation for 8075644.
05How long does a charge last in use?
About 4 to 8 hours depending on usage, according to the MC6-Ex brochure.