The Beamex MC6-T660 (product code Beamex 9430010) is the high-temperature model of the MC6-T family. It generates temperatures between 50 and 660 degrees C and adds the functions of a multifunction process calibrator and fieldbus communicator to a portable dry block.

Active triple-zone temperature control gives a flat axial temperature profile and compensates for the heat loss caused by sensors in the insert. The control algorithm heats and cools without overshoot, and the control speed can be adjusted between speed and accuracy. An accredited calibration certificate is included as standard.

This page describes Beamex MC6-T660 multifunction temperature calibrator and communicator for buyers who need the exact part number Beamex 9430010. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the data below is taken from the manufacturer published product pages and brochures.

Key features of 9430010

  • Temperature generation from 50 to 660 degrees C with active triple-zone control.
  • Display uncertainty with internal reference from plus or minus 0.2 degrees C at 50 degrees C to plus or minus 0.5 degrees C at 660 degrees C, per the brochure.
  • Built-in field communicator for HART, FOUNDATION Fieldbus H1 and Profibus PA.
  • Tilt sensor, warning light and stand-alone overheating protection.
  • Heating from 50 to 660 degrees C in about 15 minutes and cooling from 660 to 100 degrees C in about 25 minutes.
  • Works with Beamex CMX and LOGiCAL software for automated, documented calibration.

Technical specifications for 9430010

Product code 9430010 (MC6-T660)
Temperature range at 23 degrees C 50 to 660 degrees C (122 to 1220 degrees F)
Display uncertainty, internal reference 0.2 degrees C at 50; 0.3 at 420; 0.5 at 660 degrees C (plus or minus)
Stability (30 minutes, 2 sigma) 0.02 at 50; 0.03 at 420; 0.04 at 660 degrees C (plus or minus)
Axial uniformity at 40 mm 0.05 at 50; 0.25 at 420; 0.40 at 660 degrees C (plus or minus)
Hysteresis plus or minus 0.15 degrees C
Display resolution 0.001 degrees C / F / K
Immersion depth 150 mm (5.9 in)
Insert outer dimension 24.5 mm (0.96 in)
Heating time 50 to 660 degrees C: 15 min
Cooling time 660 to 50 degrees C: 35 min; 660 to 100 degrees C: 25 min
Stabilization time 10 min
Dimensions (D x W x H) 322 x 180 x 298 mm
Weight 8.6 kg (18.96 lb)
Power requirements 115 V or 230 V plus or minus 10 percent, 50/60 Hz, 1560 W
Mains fuse 230 V: T 8 A 250 V; 115 V: T 16 A 250 V
Display 5.7 inch TFT touch screen
Battery Rechargeable lithium-ion, 4300 mAh, 11.1 V
Warranty 3 years; 1 year for the battery pack

All values above come from the manufacturer documentation and may change with later revisions. Please quote 9430010 when you need the matching datasheet or a confirmation of the current revision.

Typical applications in Oman and the GCC

Power stations, refineries and process plants in the GCC use high-range dry blocks to check thermocouples and RTDs that serve furnaces, boilers and heat exchangers before reinstalling them.

Calibration laboratories and instrument shops value the low gradient and the one-box approach, because the same device can also check the transmitter and loop electronics.

Typical sectors are oil and gas production and processing, refining and petrochemicals, power generation, desalination and water treatment, pharmaceutical and food manufacturing, and calibration service providers across Oman, the UAE, Saudi Arabia, Qatar, Kuwait and Bahrain.

Selection and compatibility notes for 9430010

Choose the T660 for process sensors that need verification up to 660 degrees C, such as thermocouples and RTDs in furnaces, heaters and steam lines. For sub-ambient work down to minus 30 degrees C the lower-range model is MC6-T150 (9430020).

The fuse size depends on the supply: spare kits are 8129770 for 115 V and 8129760 for 230 V. Inserts are ordered separately and removed with tool 8129750. A transport case is sold as 8129900, and the RPRT-660-300 (9405200) is a matching high-range reference sensor.

Before ordering 9430010, confirm the model and, where relevant, the serial number or option code of the instrument it will serve. Confirm voltage, plug type, thread type or pressure rating as applicable, and check the manufacturer documentation for the firmware or hardware revision of the equipment.

If an item looks similar but carries a different part number, do not assume interchangeability. A short note of the calibrator model and application lets us confirm the match for 9430010 before it is supplied.

Installation and commissioning of 9430010

Unpack 9430010 and check the delivery against the standard accessories list before taking it to site. Charge the battery fully before the first job, confirm the date, time and language in the Settings view, and read the user manual for your firmware version. Connect test leads or pressure hoses only when the unit is idle, and always check the connection diagram shown on the screen for the selected function.

For pressure work attach the pressure module, a hose set suited to the pressure range and the right fittings, and vent the system slowly. For loop work use the built-in loop supply and keep the maximum input voltage of the calibrator in mind. After commissioning, run a short verification against a known reference so the first documented result is trustworthy.

Maintenance and care

Keep the calibrator clean and dry, store it in its case and avoid leaving it in a hot vehicle. Check the condition of test leads, clips and pressure hoses before each campaign, because worn accessories are the most common cause of unstable readings. Follow the recalibration interval set by your quality system, and use the accredited certificate delivered with 9430010 as the starting point for the history.

Update firmware and device description files only from the manufacturer download area, and record the version in your calibration log. If a part such as a battery, charger, case or fuse needs replacing, order the exact spare part number rather than a lookalike.

Calibration is only as useful as its records. Keep a log of serial numbers, certificate dates, replacement parts and any faults, and store the manufacturer documents with the equipment. This makes audits easier, helps predict when spares will be needed, and shortens the time needed to prepare a purchase request when a part has to be replaced at short notice.

Related products and ordering notes for 9430010

Typical companions for 9430010 are a protective case, a spare battery pack, pressure hoses and fittings, reference temperature sensors and calibration management software. Many of these are separate part numbers, so list them in the same enquiry to receive one consolidated reply.

Hard-to-find and discontinued spare parts are a daily topic for maintenance planners in oil, gas, power and water facilities. When a plant standardises on one calibrator family, a small stock of the exact spares is far cheaper than a day of lost production, and an early enquiry gives the supplier time to confirm availability and shipping options to Oman and neighbouring countries.

Please note that Seven Star LLC prepares each quotation for 9430010 against the exact part number, so a request that quotes the number and the quantity is answered faster than a general description.

The part number 9430010 should be quoted exactly as printed in this page, because accessories and spares with similar descriptions often differ by one digit.

Frequently asked questions about 9430010

  • What temperature range does 9430010 cover? It generates 50 to 660 degrees C. The related MC6-T150 covers minus 30 to 150 degrees C.
  • Which fuses are required? The fuse size is T 8 A 250 V for 230 V mains and T 16 A 250 V for 115 V mains. Spare kits are 8129760 (230 V) and 8129770 (115 V).
  • How fast does it heat up? The brochure gives about 15 minutes from 50 to 660 degrees C, and about 35 minutes to cool from 660 to 50 degrees C.
  • What safety features are fitted? A tilt sensor, a warning light and a stand-alone overheating protector are fitted, and heating is switched off when the unit is tilted too far.
  • Does the calibrator communicate with software? Yes. It works with Beamex CMX and LOGiCAL calibration management software, including wireless transfer over Bluetooth.

Documents and quotation

The manufacturer brochure for this product family is available as a datasheet document on this page. To request a quotation, send the RFQ to Seven Star LLC with the part number 9430010, the quantity required, the delivery location and any related items. We will confirm availability and lead time for 9430010 and reply with commercial terms.

Datasheets & Documents
  • PDF Datasheet Beamex 9430010 MC6-T660 Multifunction Temperature Calibrator Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 9430010 MC6-T660 Multifunction Temperature

Answers from our engineering team on installation, compatibility and integration.

01What temperature range does 9430010 cover?
It generates 50 to 660 degrees C. The related MC6-T150 covers minus 30 to 150 degrees C.
02Which fuses are required?
The fuse size is T 8 A 250 V for 230 V mains and T 16 A 250 V for 115 V mains. Spare kits are 8129760 (230 V) and 8129770 (115 V).
03How fast does it heat up?
The brochure gives about 15 minutes from 50 to 660 degrees C, and about 35 minutes to cool from 660 to 50 degrees C.
04What safety features are fitted?
A tilt sensor, a warning light and a stand-alone overheating protector are fitted, and heating is switched off when the unit is tilted too far.
05Does the calibrator communicate with software?
Yes. It works with Beamex CMX and LOGiCAL calibration management software, including wireless transfer over Bluetooth.