Brand:

Beamex 9250000 MC6-Ex Intrinsically Safe Calibrator

Description

Overview of Beamex MC6-Ex intrinsically safe calibrator and communicator Beamex 9250000

The Beamex MC6-Ex (product code Beamex 9250000) is an intrinsically safe advanced field calibrator and communicator. It is ATEX, IECEx and North American certified, with an Ex ia IIC T4 Ga classification, and is intended for potentially explosive environments such as offshore platforms, refineries and chemical and petrochemical plants where flammable gases may be present.

Like the standard MC6, it calibrates pressure, temperature and electrical signals and acts as a multi-bus communicator for HART, FOUNDATION Fieldbus and Profibus PA instruments. A 5.7 inch colour touch screen, an IP65 case and a field-replaceable NiMH smart battery pack make Beamex 9250000 a practical single tool for hazardous area instrument work. Every unit is delivered with an accredited calibration certificate.

This page describes Beamex MC6-Ex intrinsically safe calibrator and communicator for buyers who need the exact part number 9250000. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the data below is taken from the manufacturer published product pages and brochures.

Key features of 9250000

  • Intrinsically safe: ATEX marking II 1 G Ex ia IIC T4 Ga, with IECEx and North American (Class I, Zone 0 and Division 1, Groups A to D, T4) approvals.
  • One-year uncertainty starting from plus or minus (0.01 percent of full scale plus 0.025 percent of reading) for pressure, per the manufacturer brochure.
  • RTD measurement uncertainty starting from plus or minus 0.015 degrees C, and current measurement uncertainty starting from plus or minus (1 microamp plus 0.01 percent of reading).
  • Five operating modes: meter, calibrator, documenting calibrator, data logger and fieldbus communicator.
  • Smart NiMH battery pack that can be charged inside or outside the calibrator, using the dedicated BC15-Ex charger away from the hazardous area.
  • Integration with Beamex CMX and LOGiCAL calibration management software for paperless calibration records.

Technical specifications for 9250000

Product code 9250000
Ex marking (ATEX) II 1 G Ex ia IIC T4 Ga, Ta -10 to +50 degrees C
Ex marking (North America) Class I, Zone 0, AEx ia IIC T4 Ga; Class I, Division 1, Groups A-D, T4
Certificates ATEX EESF 18 ATEX 071X; IECEx EESF 18.0033X
Display 5.7 inch diagonal, 640 x 480 TFT LCD, adjustable LED backlight
Weight 2.5 to 2.9 kg (5.5 to 6.4 lb)
Dimensions (D x W x H) 207 x 231 x 80 mm
Battery pack Rechargeable NiMH, 4200 mAh, 9.6 V
Charging time 10 hours from 0 to 100 percent at 0 to 30 degrees C
Charger supply 100 to 240 VAC, 50 to 60 Hz
Battery operation 4 to 8 hours (heavy to normal usage)
Operating temperature -10 to 50 degrees C (0 to 40 degrees C while charging)
Storage temperature -20 to 60 degrees C
Humidity 0 to 80 percent RH, non-condensing
Maximum input voltage 30 V AC, 30 V DC
Ingress protection IP65, IEC/EN 60529
Maximum altitude 3000 m (9842 ft)
Warranty 3 years; 1 year for the battery pack

All values above come from the manufacturer documentation and may change with later revisions. Please quote 9250000 when you need the matching datasheet or a confirmation of the current revision.

Standard delivery as stated by the manufacturer:

  • USB Type-A to Type-B communication cable (8036700)
  • Battery charger including power supply BC15-Ex (8075784) and a country-specific power cord
  • NiMH battery pack MC6-Ex (8075644), installed
  • Banana test leads, clips and a thermocouple lead (8066800, 8066810, 8066811, 8036820)

Typical applications in Oman and the GCC

Offshore platforms, gas plants and refineries in Oman and the Gulf have many classified areas where only intrinsically safe test equipment may be used. 9250000 allows technicians to verify transmitters and loops in place without a hot work permit for the tool itself, subject to the site rules.

Petrochemical and fertiliser complexes use it for turnaround instrument checks, and the documenting mode records results that can be moved to calibration software after leaving the area.

Typical sectors are oil and gas production and processing, refining and petrochemicals, power generation, desalination and water treatment, pharmaceutical and food manufacturing, and calibration service providers across Oman, the UAE, Saudi Arabia, Qatar, Kuwait and Bahrain.

Selection and compatibility notes for 9250000

The MC6-Ex is the correct choice when the calibration task is inside a classified area. The standard MC6 and the MC6-T are not intrinsically safe. Accessories used with the Ex model must also be suitable: the soft case for MC6-Ex is made of antistatic material and is listed for hazardous areas, whereas the hard cases and the Bluetooth adapter sold for the standard MC6 are not.

Because intrinsic safety depends on traceable parts, the manufacturer asks for the calibrator serial number when a battery pack is ordered as a spare. The pack must only be charged with the BC15-Ex charger and never inside the hazardous area. Check the Ex marking, the ambient limits and the certificate numbers against your site permit before use.

Before ordering 9250000, confirm the model and, where relevant, the serial number or option code of the instrument it will serve. Confirm voltage, plug type, thread type or pressure rating as applicable, and check the manufacturer documentation for the firmware or hardware revision of the equipment.

If an item looks similar but carries a different part number, do not assume interchangeability. A short note of the calibrator model and application lets us confirm the match for 9250000 before it is supplied.

Installation and commissioning of 9250000

Unpack 9250000 and check the delivery against the standard accessories list before taking it to site. Charge the battery fully before the first job, confirm the date, time and language in the Settings view, and read the user manual for your firmware version. Connect test leads or pressure hoses only when the unit is idle, and always check the connection diagram shown on the screen for the selected function.

For pressure work attach the pressure module, a hose set suited to the pressure range and the right fittings, and vent the system slowly. For loop work use the built-in loop supply and keep the maximum input voltage of the calibrator in mind. After commissioning, run a short verification against a known reference so the first documented result is trustworthy.

Maintenance and care

Keep the calibrator clean and dry, store it in its case and avoid leaving it in a hot vehicle. Check the condition of test leads, clips and pressure hoses before each campaign, because worn accessories are the most common cause of unstable readings. Follow the recalibration interval set by your quality system, and use the accredited certificate delivered with 9250000 as the starting point for the history.

Update firmware and device description files only from the manufacturer download area, and record the version in your calibration log. If a part such as a battery, charger, case or fuse needs replacing, order the exact spare part number rather than a lookalike.

Calibration is only as useful as its records. Keep a log of serial numbers, certificate dates, replacement parts and any faults, and store the manufacturer documents with the equipment. This makes audits easier, helps predict when spares will be needed, and shortens the time needed to prepare a purchase request when a part has to be replaced at short notice.

Related products and ordering notes for 9250000

Typical companions for 9250000 are a protective case, a spare battery pack, pressure hoses and fittings, reference temperature sensors and calibration management software. Many of these are separate part numbers, so list them in the same enquiry to receive one consolidated reply.

Hard-to-find and discontinued spare parts are a daily topic for maintenance planners in oil, gas, power and water facilities. When a plant standardises on one calibrator family, a small stock of the exact spares is far cheaper than a day of lost production, and an early enquiry gives the supplier time to confirm availability and shipping options to Oman and neighbouring countries.

Please note that Seven Star LLC prepares each quotation for 9250000 against the exact part number, so a request that quotes the number and the quantity is answered faster than a general description.

The part number 9250000 should be quoted exactly as printed in this page, because accessories and spares with similar descriptions often differ by one digit.

When ordering 9250000 for a fleet of calibrators, mention the calibrator models in use so that compatibility can be checked before the quotation is issued.

In short, MC6-Ex IS Calibrator is a part that is easiest to source when the exact number 9250000 is known, and this page lists that number together with its specification and compatibility notes so it can be checked against your records.

Frequently asked questions about 9250000

  • What protection class does the MC6-Ex have? It is classified Ex ia IIC T4 Ga with ATEX marking II 1 G, with IECEx and North American certification, as stated in the manufacturer brochure.
  • Can I charge the MC6-Ex inside a hazardous area? No. The manufacturer states that the charger and the battery pack charging must be done outside the hazardous area and only with the BC15-Ex charger.
  • How long does the battery last? The NiMH pack gives 4 to 8 hours of operation depending on usage, and charging from empty takes about 10 hours at 0 to 30 degrees C.
  • What signals can the calibrator handle? It measures and generates pressure, temperature and electrical signals and communicates with HART, FOUNDATION Fieldbus and Profibus PA devices through the communicator options.
  • Is a calibration certificate included? Yes. Each unit is delivered with a traceable, accredited calibration certificate according to the manufacturer.

Documents and quotation

The manufacturer brochure for this product family is available as a datasheet document on this page. To request a quotation, send the RFQ to Seven Star LLC with the part number 9250000, the quantity required, the delivery location and any related items. We will confirm availability and lead time for 9250000 and reply with commercial terms.

Datasheets & Documents
  • PDF Datasheet Beamex 9250000 MC6-Ex Intrinsically Safe Calibrator Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 9250000 MC6-Ex Intrinsically Safe Calibrator

Answers from our engineering team on installation, compatibility and integration.

01What protection class does the MC6-Ex have?
It is classified Ex ia IIC T4 Ga with ATEX marking II 1 G, with IECEx and North American certification, as stated in the manufacturer brochure.
02Can I charge the MC6-Ex inside a hazardous area?
No. The manufacturer states that the charger and the battery pack charging must be done outside the hazardous area and only with the BC15-Ex charger.
03How long does the battery last?
The NiMH pack gives 4 to 8 hours of operation depending on usage, and charging from empty takes about 10 hours at 0 to 30 degrees C.
04What signals can the calibrator handle?
It measures and generates pressure, temperature and electrical signals and communicates with HART, FOUNDATION Fieldbus and Profibus PA devices through the communicator options.
05Is a calibration certificate included?
Yes. Each unit is delivered with a traceable, accredited calibration certificate according to the manufacturer.