Brand: MICHELL Instruments
Michell XTP001 Spare Sensor and Main PCB for XTP Series
Description
Michell XTP001 overview: spare sensor and main PCB for XTP series
Michell XTP001 is the base model code on the Michell XTP601 order-code sheet for the spare sensor and main PCB for the XTP series, described as the sensor from 2012 to the present. It is the replacement for the thermo-paramagnetic sensor of the XTP analyzers.
The sensor is configured in the same way as the analyzer: the order sheet lists cell O-ring material (Viton or Ekraz), the oxygen range, the background gas and the cell temperature, and the sensor must match the calibration of the analyzer it replaces.
The datasheet explains that the sensing elements are coated in borosilicate glass and mounted on platinum wire, which gives resistance to corrosion and low permeation by hydrogen or helium.
The image shows the XTP601-EX1 analyzer from the manufacturer datasheet, the host instrument of this sensor; it is not a close-up of the sensor.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Michell XTP001 so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.
Key features of XTP001
- Spare sensor and main PCB for the XTP series, sensor 2012-present.
- Configured by O-ring (Viton or Ekraz), oxygen range, background gas and cell temperature.
- Thermo-paramagnetic sensing with no moving parts.
- Background gas options include nitrogen, carbon dioxide, methane, hydrogen, biogas, natural gas mixture, argon and helium.
XTP001 technical specifications
The manufacturer lists XTP001 by configuration; the values below describe the options on the order-code sheet and the host XTP analyzer.
| Parameter | Value |
|---|---|
| Order code | XTP001 |
| Description (manufacturer) | Spare sensor and main PCB for XTP series; sensor 2012-present |
| Cell O-ring options | Viton A or Ekraz |
| Range options | 0 to 0.5 up to 0 to 50 percent O2; 20, 80 or 90 to 100 percent O2; special air-ingress calibrations |
| Background gas options | N2, CO2, CH4, H2, biogas, natural gas C8 mixture, Ar, He |
| Cell temperature options | Plus 50 degC or plus 60 degC |
| Host technology | Thermo-paramagnetic oxygen sensor |
| Host accuracy | Better than plus or minus 1 percent of range or plus or minus 0.02 percent O2 |
Typical applications of XTP001 in Oman and the GCC
- Replacing the sensor of an XTP601 or XTP501 oxygen analyzer.
- Keeping a calibrated spare for blanketing gas analyzers.
- Restoring analyzers on nitrogen, biogas or hydrogen duty after a sensor fault.
Spare parts are what keep an installed analyzer running through a shutdown window. Plants in Oman and the GCC often hold single critical spares on site because lead times from overseas can be long, and a clear, exact part number such as XTP001 removes ambiguity when a maintenance planner raises a purchase request.
Selection and compatibility notes
The sensor must be ordered with the same range, background gas, O-ring and cell temperature as the analyzer. Send us the analyzer order code or the data on the nameplate, and for flammable backgrounds confirm that the analyzer is an explosion-proof or flame-arrestor model.
Spare parts for process analyzers are not interchangeable by description alone. Before ordering XTP001, give us the model code and serial number of the host instrument, because variants and production years can use different assemblies, and we will compare them against the manufacturer spares list.
Installation and commissioning of XTP001
Follow the manual for sensor replacement on the analyzer and the permit rules for the area. After replacement, calibrate the analyzer in the process background gas at the sample pressure.
Fit this item only when the analyzer is isolated, depressurised and de-energised according to your permit-to-work, and follow the service instructions in the manufacturer manual. After replacement, re-verify the instrument against a known reference, check for leaks on any wetted parts, and record the change in the maintenance log.
Maintenance, calibration and service
Keep a record of the sensor serial number and calibration, and check the cell O-ring condition during replacement.
Keep a replacement log that shows the date of fitting, the instrument serial number and the reason for the change, so that future failures can be correlated with operating conditions. Store spares in clean, dry packaging at moderate temperature until they are needed.
Related products and ordering notes for XTP001
- XTP601-GP1: general-purpose analyzer.
- XTP601-EX1: explosion-proof analyzer.
- XTP601-EX-HMI: display assembly.
When you request XTP001, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.
Frequently asked questions about XTP001
- What is XTP001? XTP001 is the manufacturer base model code for the spare sensor and main PCB of the XTP series thermo-paramagnetic oxygen analyzers.
- What does XTP001 suit? It is a replacement sensor for XTP601 and XTP series analyzers, configured to the analyzer range and background gas.
- What must be specified when ordering XTP001? State the O-ring material, the oxygen range, the background gas and the cell temperature, matching the analyzer it will replace.
- What should I send with an RFQ for XTP001? Send the part number XTP001, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The XTP series datasheet describes the host instrument.
Documents and quotation
The official Michell Instruments XTP601 Process Oxygen Analyzer User’s Manual (97313) is attached to this page as a PDF. Appendix A (Technical Specifications, manual page 36) identifies the measurement technology as a thermo-paramagnetic oxygen sensor with accuracy better than ±1 % of span, and section 1.3 (O-Ring Selection, manual page 3) explains why the cell O-ring material must match the process gas. Quote part number XTP001 and your analyzer serial number in your request so we can check the match before we send a written quotation.
Other Models in the Michell Xtp601 Range
Seven Star LLC supplies models from the Michell Xtp601 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Michell XTP601-GP1 Thermo-Paramagnetic Oxygen Analyzer | Gas Analyzer Systems | View details |
| Michell XTP601-EX1 Explosion-Proof Oxygen Analyzer | Gas Analyzer Systems | View details |
| Michell XTP601-EX-HMI Display Assembly for XTP601 EX Analyzer | Gas Analyzer Systems | View details |
| Michell XTP001 Spare Sensor and Main PCB for XTP Series | Gas Analyzer Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Michell XTP601 Process Oxygen Analyzer User Manual 97313 (official PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Michell XTP001 Spare Sensor and Main PCB for XTP
Answers from our engineering team on installation, compatibility and integration.
01What is XTP001?
XTP001 is the manufacturer base model code for the spare sensor and main PCB of the XTP series thermo-paramagnetic oxygen analyzers.
02What does XTP001 suit?
It is a replacement sensor for XTP601 and XTP series analyzers, configured to the analyzer range and background gas.
03What must be specified when ordering XTP001?
State the O-ring material, the oxygen range, the background gas and the cell temperature, matching the analyzer it will replace.
04Can Seven Star LLC supply XTP001 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for XTP001?
Send the part number XTP001, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The XTP series datasheet describes the host instrument.