Brand:

Fluke 175 True-RMS Digital Multimeter, CAT III 1000 V

Description

175 baseline true-RMS multimeter for industrial work explained

The Fluke 175 True-RMS Digital Multimeter (175) is the entry model of the Fluke 170 series. It carries the same ranges, safety category and rugged body as the 177 and 179, with a slightly relaxed DC voltage accuracy, which makes it an economical general-purpose instrument. Seven Star LLC supplies 175 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The 175 is the reference point for the family, so the decoding below shows what is shared and what changes upward.

Element Value Meaning
175 Model Baseline model of the 170 series
±(0.15% + 2) Best DC voltage accuracy Looser than the 0.09% of the 177 and 179
True-RMS Measurement method Accurate on distorted waveforms
CAT III 1000 V / CAT IV 600 V Category All inputs protected to this level

175 technical specifications

Parameter Specification
Manufacturer / part number Fluke / 175
DC voltage Up to 1000 V, ±(0.15% + 2), resolution 0.1 mV
AC voltage (true-RMS) Up to 1000 V, ±(1.0% + 3)
DC current Up to 10 A, ±(1.0% + 3)
AC current (true-RMS) Up to 10 A, ±(1.5% + 3)
Resistance Up to 50 MΩ, ±(0.9% + 1)
Capacitance Up to 10,000 µF, ±(1.2% + 2)
Frequency Up to 100 kHz, ±(0.1% + 1)
Safety rating 1000 V CAT III, 600 V CAT IV; UL, CSA, TUV listed
Operating / storage temperature -10 °C to +50 °C / -30 °C to +60 °C
Size / weight 43 x 90 x 185 mm / 420 g
Battery life About 200 hours typical, alkaline, without backlight
Warranty Lifetime

Figures come from the manufacturer product page for the Fluke 175 and are best accuracy for each function.

How the Fluke 175 True-RMS Digital Multimeter works

The 175 uses the same measurement engine layout as the rest of the series: input protection, range selection, true-RMS conversion and a 6000-count display. Because all inputs are protected to CAT IV 600 V and CAT III 1000 V, the same instrument can be used on a motor terminal box and on a distribution board without changing meters.

Display Hold and Auto Hold capture a stable value so you can record it later. The auto-hold function is useful when both hands are busy with probes and the display is hard to see; it latches when the reading settles and beeps to confirm.

Key features

  • All inputs protected to CAT IV 600 V and CAT III 1000 V
  • Display Hold and Auto Hold
  • Ergonomic case with integrated holster
  • Closed-case calibration through the front panel
  • Frequency, capacitance, resistance, continuity and diode tests

Where 175 fits and related Fluke models

Choose the 175 when the job is general troubleshooting and a DC accuracy of 0.15% is more than enough, for example checking supplies and continuity. If you later need higher DC accuracy, the 177 is the next step, and the 179 adds temperature.

The 175 is also the family member most often kept in tool cribs, where many instruments are issued to different technicians and cost control matters.

Selection checklist for 175

Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.

  • DC accuracy needs: 0.15% is adequate for power circuits and most control wiring.
  • Temperature and logging are not included.
  • Direct current is limited to 10 A.
  • Check how many leads and clips each technician needs.

Safe use, care and maintenance of 175

  • Before each shift, inspect the case, the holster and the test leads. Cracked insulation, exposed metal or a loose input jack means the leads should be replaced before the 175 touches any live circuit.
  • Confirm the meter on a known live source before and after a measurement that decides whether a circuit is dead. Never rely on a single reading when the result will be used to release a lock-out.
  • Keep the input fuses to the specified type only. A blown fuse in the current inputs is the most common service event on a multimeter used on motor circuits, and a wrong fuse defeats the safety design of the Fluke 175 True-RMS Digital Multimeter.
  • Replace the battery when the low-battery symbol appears, because readings near the lower end of the range become unreliable on a weak cell. Remove the battery before long storage.
  • Store the instrument clean and dry. In coastal Oman, wipe off salt film and condensation after outdoor use and avoid leaving it in a vehicle cabin in summer.

Typical applications of 175 in Oman and the GCC

Handheld multimeters are carried in every plant. In Oman, oil and gas facilities, power stations, desalination plants and petrochemical sites rely on them for control-panel faults, motor circuits, instrument loops and routine electrical checks.

In industrial plants the 175 serves as a shared workshop meter and as the default instrument for apprentices and junior technicians. It copes with panel work, motor circuits and utility checks, and its rugged holster tolerates the knocks of shutdown work on Oman refinery, power and water sites.

175 compared with nearby models

Model DC accuracy (best) Temperature Typical user
175 ±(0.15% + 2) No Tool crib, general maintenance
177 ±(0.09% + 2) No Instrument technician
179 ±(0.09% + 2) Yes Electrical and thermal checks

Only the DC accuracy and the temperature input separate the three models; the other ranges are the same.

Information to send with an RFQ for 175

To prepare an accurate quotation, please send:

  • Exact model 175 and the quantity required.
  • Whether the meter is for a lab, a workshop or field service, so the correct accessory set can be quoted.
  • Required test lead type and any extra clips or probes.
  • Temperature probe, case or magnetic hanger requirements.
  • Whether calibration traceability paperwork is needed on delivery.
  • Delivery point in Oman or elsewhere in the GCC and the required date.

Documents and quotation

A manufacturer datasheet for the Fluke 175 True-RMS Digital Multimeter is attached on this page so that you can check the full specification before ordering. Please review it against your site requirements.

For a quotation, send the part number 175, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.

Other Models in the Fluke 170 Series Dmm Range

Seven Star LLC supplies models from the Fluke 170 Series Dmm range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Fluke 177 True-RMS Digital Multimeter, CAT III 1000 VElectrical Testers & MultimetersView details
Fluke 175 True-RMS Digital Multimeter, CAT III 1000 VElectrical Testers & MultimetersYou are viewing this model
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 175 True-RMS Digital Multimeter, CAT III 1000

Answers from our engineering team on installation, compatibility and integration.

01What is the difference between Fluke 175, 177 and 179?
All three share ranges and the CAT III 1000 V rating. The 175 has the lowest DC accuracy, the 177 improves it to 0.09%, and the 179 adds temperature measurement.
02Is the Fluke 175 a true-RMS meter?
Yes. It measures true-RMS AC voltage and current, giving correct values on non-linear loads such as drives and switch-mode supplies.
03What current can the 175 measure directly?
Up to 10 A AC or DC through the current inputs. For larger currents use a clamp meter with a suitable range.
04Does the 175 have a backlight?
Yes, it has a backlit display with an analog bar graph. The quoted battery life of about 200 hours is without the backlight.
05Can the 175 be calibrated without opening the case?
Yes, the manufacturer lists closed-case calibration through the front panel, which simplifies periodic calibration.