Schneider Electric AP9640 APC Network Management Card 3 (NMC3)

Description

AP9640 Network Management Card 3 (NMC3) for APC UPS

The AP9640 is the APC Network Management Card 3, a plug-in card that gives a compatible UPS its own network connection for remote monitoring and management. The datasheet describes it as a device for monitoring and management with secure remote access, a 10/100/1000BASE-T network interface and a micro-USB cable in the box. Seven Star LLC supplies the AP9640 in Oman and the GCC as an independent supplier based in Muscat.

A UPS without a network card can only warn locally. With the AP9640 installed, the UPS can be viewed and configured over the network, send notifications and report to monitoring software. The key question when ordering is compatibility: the datasheet lists the families the card is intended for, and the list is reproduced below.

What the AP9640 adds beyond a basic UPS interface

Compared with a simple contact or serial interface, an NMC gives each UPS an address on the LAN. The card in this page is the third generation, and the datasheet places it across single-phase and three-phase UPS ranges, from Smart-UPS to Galaxy and Symmetra families. That breadth is useful for a site with mixed UPS sizes because one management approach can cover them.

AP9640 technical specifications

Parameter Specification
Manufacturer / part number Schneider Electric / AP9640
Range of product Network Management Cards
Product type Device monitoring and management
Provided equipment Micro-USB cable; Installation manual
Number of input phases (UPS) 1 / 3
Communication network type 10/100/1000BASE-T
Authentication Radius; Lightweight Directory Access Protocol (LDAP)
Net weight 0.08 kg
Dimensions W x H x D 12.1 cm x 3.8 cm x 11.4 cm
Operating temperature -5–45 °C
Storage temperature -15–65 °C
Relative humidity (operating and storage) 0–95 %
Operating altitude 0–10000 ft
Storage altitude 0–15240 m
Product certifications FCC Class A; AS/NZS; AS/NZS 3548 (C-Tick) class A; FCC part 15 class A; GOST; UK PSTI
Warranty 24 months

UPS families supported by the AP9640

The datasheet names the following UPS ranges under range compatibility. Always confirm the exact UPS model and its card slot before ordering, because the list is by family and not by individual part number.

  • Galaxy VM
  • Galaxy VX
  • Symmetra PX
  • Easy UPS 3M Advanced
  • Easy UPS 3-Phase Modular
  • Galaxy PX
  • Galaxy 3L Pro
  • Smart-UPS
  • Smart-UPS Ultra
  • Smart-UPS Online
  • Smart-UPS Modular Ultra
  • Smart-UPS Battery Systems
  • Back-UPS SX3
  • Refurbished Smart-UPS

Protocols and security features of the AP9640

For management access the datasheet lists these communication protocols: HTTP over secure sockets; Layer (HTTPS); SSH; FTP; HTTP; SNMP; DHCP; BOOTP (Bootstrap Protocol); TCP/IP. Authentication options are Radius; Lightweight Directory Access Protocol (LDAP). Having HTTPS and SSH alongside plain HTTP and FTP means the card can be run in a secured mode, but the unsecured services should be disabled in line with your network policy.

Management traffic runs over a 10/100/1000BASE-T interface. A micro-USB cable is provided for local configuration, which is the usual way to give the card its first IP settings before it joins the network.

EMC and approval information for the AP9640

Standards listed include EN 55024, BS EN 55024, EN 61000-4-2, BS EN 61000-4-2, EN 61000-4-3, BS EN 61000-4-3 and others in the EN 55024, EN 61000-4 and EN 62040-2 groups, with certifications FCC Class A; AS/NZS; AS/NZS 3548 (C-Tick) class A; FCC part 15 class A; GOST; UK PSTI. These are the figures on the datasheet; for any project that needs a specific approval document, tell us the requirement and we will confirm what is available.

Selection checklist for the AP9640

  • UPS family and model are on the compatibility list.
  • The UPS has a free card slot and is not already fitted with a management card.
  • Network port speed is 10/100/1000 Mbit/s copper.
  • Security policy: which protocols may stay enabled.
  • Monitoring software or building-management system that will read the card.
  • Operating environment: -5 to 45 °C, 0 to 95 % relative humidity.

Installation and commissioning of the AP9640

Fit the card in the UPS accessory slot according to the installation manual supplied in the box, connect the network cable and use the micro-USB cable for first-time setup. Assign a fixed address or reserve one on the DHCP server so the device always comes up at a known address.

After configuration, change the default credentials, set up e-mail or SNMP notifications and run a test alarm. Keep the configuration backup with the site documentation so a replacement card can be set up quickly.

Plan the network side as carefully as the electrical side: put the card on a management VLAN where possible, restrict access to the monitoring station, and document the address, community strings or accounts in the site records. A card that is reachable from anywhere on a flat network is a security risk, however useful the data is.

Where the AP9640 is used in Oman and the GCC

Remote UPS visibility matters in unmanned sites: telecom rooms, pumping stations, substations, data rooms and branch offices spread across Oman. Battery condition, input quality and load level reported over the network let operators plan site visits instead of reacting to a failed bypass or battery. Mind the operating range of -5 to 45 °C: UPS rooms in hot locations need adequate cooling for both the UPS and the card.

A common arrangement is one monitoring system collecting every UPS card across a company, with e-mail alerts to the maintenance team for on-battery events. The same cards can feed a building-management or SCADA system through SNMP, which the datasheet lists among supported protocols.

Documents and quotation

The official Schneider Electric datasheet of this unit is attached on this page for download, so every figure above can be checked against the source.

To request a quotation, send us the part number AP9640, the quantity and the delivery location through the RFQ form. Seven Star LLC replies with availability and lead time.

Datasheets & Documents
  • PDF Datasheet Schneider Electric AP9640 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric AP9640 APC Network Management

Answers from our engineering team on installation, compatibility and integration.

01What is the AP9640?
The APC Network Management Card 3 (NMC3), a card that gives a compatible UPS a network interface for secure remote monitoring and management.
02Which UPS families does the AP9640 support?
The datasheet lists Galaxy VM, VX, PX and 3L Pro, Symmetra PX, Easy UPS 3M Advanced and 3-Phase Modular, Smart-UPS, Smart-UPS Ultra, Online and Modular Ultra, Smart-UPS Battery Systems, Back-UPS SX3 and refurbished Smart-UPS. Check your exact model before ordering.
03What network interface does the AP9640 have?
The datasheet gives 10/100/1000BASE-T, with HTTPS, SSH, FTP, HTTP, SNMP, DHCP, BOOTP and TCP/IP listed as protocols.
04What is supplied with the AP9640?
A micro-USB cable and an installation manual.
05What operating conditions does the AP9640 accept?
-5…45 °C in operation, -15…65 °C in storage, and relative humidity of 0…95 %.