- Automation & ControlView all 1,840 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Industrial Computers
- Servo Drives
- Motor Soft Starters
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: Flowserve
Flowserve Worthington HED API 610 BB2 Two-Stage Pump
Description
Flowserve HED API 610 BB2 two-stage pump: what it is
The Flowserve HED is a two-stage, radially split pump of the API 610 BB2 type, sold under the Worthington name together with its sister model HED-DS. Two impellers in series on one shaft raise the head far beyond what a single stage can reach, while the radially split casing, with its parting plane perpendicular to the shaft, is the construction preferred for high pressures and high temperatures.
Seven Star LLC supplies Flowserve HED pumps in Oman and the GCC as an independent supplier in Muscat. The HED is a series: pump size, materials, nozzle arrangement and sealing are set from the duty. This page summarises the published range and the data we need to prepare a quotation.
HED technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Flowserve (Worthington) / HED |
| Pump type | Two-stage, radially split, centreline-mounted between-bearings pump |
| Standard | ISO 13709 / API 610, type BB2 |
| Flow | Up to 2000 m³/h (8800 gpm) |
| Head | Up to 650 m (2100 ft) |
| Pressure | Up to 120 bar (1750 psi) |
| Temperature | Up to 450 °C (842 °F) |
| Size range | 2 in to 12 in |
| Casing | Single or dual volute, staggered arrangement |
| Nozzle configurations | Top-top, side-top, side-side |
| Seal chambers | ISO 21049 / API 682 |
| Frequency | 50 or 60 Hz capability |
How the HED two-stage radially split design works
Liquid enters the first-stage impeller, gains energy, and is carried to the second stage, which adds a second increment of head. The staged build allows the HED to generate high differential pressure at moderate shaft speed, which is easier on the rotor than a single very large impeller.
The casing is heavy-duty and may be single or dual volute, with the volutes arranged in a staggered pattern. This staggering evens out the radial force on the rotor, which the product page lists as a feature for radial balance. The stiff shaft is designed to operate below its first critical speed, which keeps vibration low across the operating range and protects the mechanical seal faces.
HED nozzle configurations and the HED-DS variant
| Item | Meaning |
|---|---|
| Top-top | Suction and discharge nozzles both on top of the casing |
| Side-top | Suction on the side, discharge on top |
| Side-side | Suction and discharge both on the side |
| HED | Two-stage radially split BB2 pump |
| HED-DS | Double-suction two-stage version for lower NPSH requirement |
The best arrangement depends on how the piping approaches the pump and on plant layout, and the centreline mounting of the casing is intended to suit high-temperature operation. The nozzle-loading capability is described as going beyond API 610 limits, which gives piping designers more freedom.
Where the HED fits and related Flowserve pumps
The HED sits between single-stage process pumps and the multistage barrel or axially split designs. When the head you need is higher or pressures reach very high values, the multistage DMX axially split pump is the usual next step. For lower-pressure, large-volume water transfer, the LNN double-suction axially split pump is a better fit. The UZDL is a two-stage axially split alternative for pipeline duty at up to 64 bar.
Choosing between these depends on temperature, pressure, nozzle loading and the maintenance philosophy of the site. A radially split case like the HED is generally preferred for hot hydrocarbon service.
Selection and ordering checklist for the HED
- Process liquid, specific gravity, viscosity and vapour pressure at pumping temperature
- Rated flow, differential head and the allowable operating range
- NPSH available, which decides between HED and HED-DS
- Maximum casing temperature and design pressure including relief or shut-off conditions
- Nozzle arrangement: top-top, side-top or side-side, and flange class
- Materials per API 610 material class and any sour-service requirement
- API 682 seal type and plan, plus bearing lubrication and cooling choice
- Driver type, speed and supply frequency (50 or 60 Hz)
HED installation, commissioning and maintenance
Because the HED runs at high temperature and pressure, installation quality has a direct effect on reliability. Support the piping so nozzle loads stay within the allowable limits, align the coupling with allowance for thermal growth, and warm the pump slowly with a controlled warm-up flow to avoid thermal shock. Check seal flush and cooling lines before the first start and confirm the direction of rotation uncoupled.
In service, track vibration, bearing temperature, seal leakage and differential pressure. A rise in vibration or a drop in head can indicate wear-ring clearance growth or an operating point far from best efficiency. Plan spare mechanical seals, wear rings, bearings and gaskets in advance, and send the nameplate data when ordering parts so the correct build can be identified.
HED applications in Oman and the GCC
Heavy-duty process pumps are used throughout the region in refinery and gas-processing units, in oil-export and transfer systems, and in power and utility plants. The HED is positioned for high-temperature process service and utility duties in oil and gas, covering upstream production, midstream transportation and downstream processing.
Gulf conditions add their own demands: high ambient temperature affects bearing cooling and auxiliary systems, and dust and humidity must be considered for electrical equipment and lubricant condition. Specify the climate and location in the enquiry so cooling, oil selection and coatings are suited to the site.
Information to send with a HED RFQ
- Existing nameplate photo, or the full duty data sheet for a new pump
- Pump designation (HED or HED-DS), size and number of units
- Seal arrangement, flush plan and bearing preference
- Nozzle arrangement and flange rating
- Whether a baseplate, coupling, driver or spare parts are included
- Delivery location and required timeline
Documents and quotation
Send the HED model, size and duty data and we will confirm which documents are available and prepare a quotation. Seven Star LLC acts as an independent supplier in Muscat and is not the manufacturer.
Please mention the application and site temperature so that the correct materials and seal arrangement can be discussed before the quotation is issued.
Other Models in the Flowserve Worthington Pumps Range
Seven Star LLC supplies models from the Flowserve Worthington Pumps range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Flowserve Worthington LNN Axially Split Double-Suction Pump | Pumps | View details |
| Flowserve Worthington HED API 610 BB2 Two-Stage Pump | Pumps | You are viewing this model |
Reviews (0)
How would you rate this product? Cancel reply
About brand
Flowserve is the American flow control company for pumps, valves, mechanical seals and valve automation, known through brands such as Durco, Worthington, Byron Jackson, Valtek, Limitorque, Worcester, Logix and Argus. It was formed on 22 July 1997 by the merger of equals of Durco International and BW/IP, whose heritage reaches back to Simpson & Thompson (1790) and Byron Jackson (1872). Flowserve Corporation is headquartered in Irving, Texas, and listed on the New York Stock Exchange.
Seven Star LLC sources and supplies Flowserve pumps, seals, control valves, ball valves, actuators and positioners for process plants in Oman, working from the nameplate data and the manufacturer's documentation.
Flowserve company profile
| Formed | 22 July 1997, merger of Durco International and BW/IP |
|---|---|
| Heritage companies | Simpson & Thompson, later Worthington Simpson (1790); Byron Jackson (1872); Duriron foundry, later Durco (1912) |
| Headquarters | Irving, Texas, USA |
| Ownership | Flowserve Corporation, public company (NYSE: FLS) |
| Product families | API and ANSI process pumps, Durco and Worcester ball and plug valves, Durco TX3 triple-offset and Valtek butterfly and globe control valves, Limitorque electric actuators, Logix positioners, mechanical seals |
Milestones
- 1790: Thomas Simpson founds Simpson & Thompson, a predecessor of Worthington Simpson pumps.
- 1872: Byron Jackson is founded, a root of BW/IP.
- 1912: The Duriron foundry, later Durco, is launched.
- 1997: Durco International and BW/IP merge on 22 July to form Flowserve, listed on the NYSE as FLS.
Flowserve product families listed here
Flowserve pumps on this page are the Durco Mark 3 ANSI process pump and the ECPJ vertical sump pump built to API 610 type VS4. Sealing products are the ISC2 cartridge mechanical seal to API 682 and DuraClear barrier fluid for dual seal systems. Flowserve valves include the Valtek Mark One globe control valve, Argus floating and trunnion-mounted ball valves (EK71, FK79, FK76M) and Durco Microfinish ball valves. Automation is covered by Limitorque MX and L120 multi-turn electric actuators, the Rotadisk RD and RDF pneumatic actuator and the Logix 3800 digital positioner.
Where Flowserve equipment is used
Mark 3 pumps handle acids, caustic, solvents and utilities in chemical and petrochemical units. VS4 sump pumps drain pits and collection tanks. Valtek control valves and Argus ball valves are found in refining, gas processing, power and desalination, and Limitorque actuators operate gate and globe valves on pipelines, tank farms and water networks across the GCC.
Flowserve products we list
Ordering Flowserve parts: what we need
The serial number on the nameplate is the key to Flowserve records for a pump, valve or actuator. Please add the following by product type:
- Pumps: size and model, impeller diameter, materials, seal arrangement, and the part name and item number from the sectional drawing
- Mechanical seals: seal type and size, drawing or part number, materials code, pumped fluid and flush plan
- Valves: size, pressure class, body and trim materials, end connections, and the actuator and positioner model
- Limitorque actuators: unit size, order and serial number, supply voltage, wiring diagram number
Facts checked against Flowserve's SEC filings and published company histories, October 2026.
Browse Flowserve products by category: Control Valves, Pumps, Valve Actuator, Valve Positioner.
FAQ
Questions about the Flowserve Worthington HED API 610 BB2 Two-Stage Pump
Answers from our engineering team on installation, compatibility and integration.
01What is the Worthington HED pump?
The HED is a two-stage, centreline-mounted, radially split between-bearings pump built to the ISO 13709 / API 610 BB2 pump type. It is intended for heavy-duty process service where pressure and temperature are high and a robust, fully API-style casing is required.
02What is the difference between HED and HED-DS?
Both appear on the same product page. According to Flowserve literature, HED-DS is the double-suction two-stage version, which lowers the NPSH requirement of the first stage. Confirm which one your duty needs when you submit the hydraulic data.
03What operating limits are published for the HED?
The product page lists flows to 2000 m3/h (8800 gpm), heads to 650 m (2100 ft), pressures to 120 bar (1750 psi) and temperatures to 450 C (842 F), in sizes from 2 in to 12 in. These are envelope values, so the specific pump size must be selected against its own curve.
04Which nozzle arrangements are available?
Three configurations are listed: top-top, side-top and side-side, referring to the positions of the suction and discharge nozzles. The choice depends on piping routing and on how the casing is supported for hot service.
05Does the HED accept API 682 mechanical seals?
Yes. The pump uses seal chambers conforming to ISO 21049 / API 682, which accommodate cartridge-type single and dual seals. Specify the seal arrangement and flush plan in the enquiry so the chamber and piping are correct.


















Reviews
There are no reviews yet.