Description

Bently Nevada 288055-01 standard 3500/22M TDI module with USB cable

The Bently Nevada 288055-01 is listed in the 3500/22M datasheet spares table as the “Standard Transient Data Interface Module with USB cable”. It is a complete standard-type TDI main module for the 3500 machinery protection rack, supplied together with the isolated USB cable that the manufacturer specifies for configuring the module from a laptop. The module goes into Slot 1, next to the power supplies, and an Ethernet I/O module is fitted behind it.

Seven Star LLC offers this spare to maintenance teams in Oman and the GCC who want the module and the correct service cable in one item rather than assembling the kit from separate numbers.

288055-01 technical specifications

Parameter Specification
Manufacturer / part number Bently Nevada 288055-01
Description (datasheet spares list) Standard Transient Data Interface Module with USB cable
Companion cable 10 ft A-to-B USB cable, part 123M4610, required to keep chassis-to-ground isolation
Operating temperature -30°C to +65°C (-22°F to +149°F)
Storage temperature -40°C to +85°C
Humidity 95%, non-condensing
Power consumption 10.5 W
Rack position TDI module: 1 full-height front slot, always Slot 1 beside the power supplies; I/O module: 1 full-height rear slot
Front panel USB-B configuration port, OK / TX-RX / TM / CONFIG OK LEDs, rack reset button, address switch, RUN/PROGRAM keylock

Where a row gives no figure for the kit itself, the 3500/22M datasheet values for the standard TDI are shown.

Why the USB cable matters

The front panel of the 3500/22M has a USB-B configuration port. The datasheet is explicit that the specific cable 123M4610 is needed to preserve isolation between the chassis and ground, and that the computer connected to it should be running on battery power rather than mains ground. Otherwise a ground loop can form between the laptop and the rack. This is the practical reason to buy the module with its cable: field engineers often arrive with a generic USB lead and an AC-powered laptop, and ground-loop noise is a poor way to find out.

The USB port is used for configuration or for retrieving machinery data. For continuous data collection the module relies on the Ethernet link through the I/O module.

How 288055-01 differs from 138607-01

Both numbers describe a standard-type 3500/22M. The 138607-01 is the module on its own, while 288055-01 is documented by the manufacturer as the same standard TDI packaged with the USB cable. If your stores already hold a 123M4610 cable you may only need the module alone; if not, the kit saves a separate line item. Always check the label on the board you receive against your own stored configuration, since the dynamic data enabling disk, I/O module and agency approval are ordered separately.

System role and compatible parts

The TDI replaces the combined function of the 3500/20 Rack Interface Module and an external communication processor. It collects steady-state and transient data from M-series monitors such as the 3500/40M and 3500/42M and sends it to System 1 or to the 3500 configuration software. Compatible rear modules are 146031-01 (copper), 146031-02 (fiber), and the gold-plated 146031-03 and 146031-04. Network accessories are covered by a separate manufacturer datasheet, and the 3500 Hardening Guide describes network requirements.

Selection and ordering checklist for 288055-01

  • Check that your rack is an M-series system and that the monitors installed are listed as compatible with the 3500/22.
  • Choose the I/O module before ordering: copper or fiber, standard or gold-plated relay contacts.
  • Decide whether the dynamic data enabling disk is required and how many steady-state and transient points you need.
  • Confirm that a battery-powered laptop is available for USB configuration.
  • Check agency approval requirements for the area where the rack sits.

Installation and commissioning

Install with the rack powered down only if your site procedure requires it; 3500 modules are designed for hot insertion, but a TDI swap affects data collection and rack addressing, so plan it for a quiet period. Set the address switch to the previous value, move the keylock to PROGRAM, connect the USB cable from a battery-powered computer and load the saved configuration. Return the key to RUN when the CONFIG OK LED confirms a valid configuration. Keep the old module for fault analysis until communications with the host have been confirmed over several hours.

Applications in Oman and the GCC

Typical homes for this spare are the 3500 racks on gas compressors, generator sets and boiler feed pumps in oil and gas facilities, independent power and water plants and petrochemical complexes. These plants often keep one spare TDI per site because the rack cannot send data to the diagnostic software without it. Dust and heat in remote locations make sealed storage of spare electronics a sensible practice.

Related spares in the 3500/22M family

Part number Item
288055-01 Standard TDI with USB cable (this item)
138607-01 Standard TDI main module
123M4610 10 ft USB A-to-B cable
146031-01 / -02 Copper / fiber Ethernet I/O modules
00580441 / 00580436 3-position and 6-position connector headers

Information to send with your RFQ

  • Part number 288055-01 and quantity
  • Rack type, firmware and installed monitor modules
  • Type of I/O module in the rack (copper or fiber)
  • Agency approval and destination in Oman or the GCC

Related Bently Nevada products: Bently Nevada 125680-01 3500/40M Proximitor I/O Module, Bently Nevada 128240-01 3500/42M Prox/Seismic I/O Module, Bently Nevada 3500/50M Tachometer Module, Bently Nevada 3500/50 Tachometer Module, Bently Nevada 3500/46M Hydro Monitor and Bently Nevada 3500/20 Rack Interface Module.

Documents and quotation

The manufacturer datasheet for the 3500/22M family is attached on this page; read it together with your rack configuration and the site specification before confirming an order.

Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC. Stock position, lead time, condition and the certificates that travel with the shipment are confirmed in the written quotation.

Other Models in the 3500 22m Tdi Range

Seven Star LLC supplies models from the 3500 22m Tdi range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Bently Nevada 138607-01 3500/22M TDI Main ModuleVibration MonitoringView details
Bently Nevada 288055-01 3500/22M TDI Module with USB CableVibration MonitoringYou are viewing this model
Bently Nevada 146031-02 3500/22M 100Base-FX I/O ModuleVibration MonitoringView details
Datasheets & Documents
  • PDF Datasheet Bently Nevada 3500/22M TDI Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bently Nevada is the American machinery protection and condition monitoring brand behind the 3500 rack, the 3300 XL proximity probe and the System 1 software. It was founded in 1961 in Minden, Nevada, and is today a Baker Hughes business.

Seven Star LLC is an independent supplier in Muscat. We list Bently Nevada monitors, I/O modules, probes, proximitors, velocity transducers and transmitters for rotating equipment in Oman and the GCC, and source them by full part number.

Bently Nevada company profile

Established 1961, Minden, Nevada, USA, by Donald E. Bently. The business started earlier as Bently Scientific in Berkeley, California (1956).
Known for The first commercial eddy-current proximity transducers for measuring shaft vibration and position on high-speed turbomachinery
Ownership Acquired by GE Energy in 2002; part of Baker Hughes since GE Oil & Gas combined with Baker Hughes in 2017
Rack generations 5000 series (from 1965), 3300 series (from 1988), 3500 series (from 1995), Orbit 60 (current platform)
Product families Machinery protection racks, proximity probes and proximitors, Keyphasor sensors, velocity and acceleration transducers, 2-wire vibration transmitters, general-purpose monitors, portable analyzers, wireless sensors and System 1 condition monitoring software
Typical machines Steam and gas turbines, centrifugal and reciprocating compressors, pumps, motors, generators, fans and gearboxes

Milestones

  • 1956: Donald E. Bently starts Bently Scientific in Berkeley, California.
  • 1961: The company moves to Minden, Nevada, as Bently Nevada.
  • 1965: The 5000 series monitoring system is introduced.
  • 1988: The 3300 series follows.
  • 1995: The 3500 machinery protection system is launched.
  • 2002 and 2017: GE Energy acquires Bently Nevada; it becomes part of Baker Hughes in 2017.

Bently Nevada product series

Series Type What it does
3500 Machinery protection rack Continuous online protection with alarm and danger relays. Modules include the 3500/15 power supply, 3500/20 rack interface, 3500/25 Keyphasor, 3500/42M proximitor/seismic, 3500/50 tachometer, 3500/60 temperature, 3500/33 relay and 3500/92 communication gateway
3500 recip modules Reciprocating compressor monitoring 3500/70M impulse velocity, 3500/72M rod position and 3500/77M cylinder pressure
Orbit 60 Protection and monitoring platform The current Bently Nevada platform for protection, condition monitoring and data integration with System 1
3300 XL 8 mm Proximity transducer system Probe, extension cable and proximitor sensor for radial vibration, thrust position and Keyphasor reference on fluid-film bearing machines; also 5 mm and 25 mm versions
330500 Velomitor, 190501 Velomitor CT Piezo-velocity sensors Casing velocity on rolling-element bearing machines and low-speed cooling tower fans
990 and 991 2-wire transmitters 4-20 mA vibration (990) and thrust position (991) signals straight into a PLC or DCS, without a monitor rack
1900/65A, 2300 Compact monitors Protection for balance-of-plant pumps, fans and motors where a full 3500 rack is not justified

A proximity probe measures the gap to the shaft, so it sees shaft movement inside a fluid-film bearing directly. A velocity or acceleration sensor sits on the casing and suits rolling-element bearing machines. Critical turbomachinery usually carries two X-Y probes per bearing, two axial probes for thrust position and a Keyphasor probe for speed and phase.

Where Bently Nevada systems are used

In Oman and the GCC, Bently Nevada racks and probes protect gas turbines, compressors and steam turbines in gas processing, LNG, refining, petrochemical, power and desalination plants. Many installations are 3500 racks that have run for years, so most requests are for like-for-like module, probe, extension cable and proximitor replacements, plus upgrades to newer monitors.

Ordering and replacement: what we need

For probes and proximitors, send the full part number with all option digits (for example 330101-00-27-10-02-05). The digits set the probe length, cable length, connector and approvals, and the probe, cable and proximitor must match in total system length. For 3500 modules, send the module and I/O part numbers from the rack and say whether the I/O is internal or external termination, or barrier type. If a module is obsolete, we quote the replacement that Bently Nevada names and point out any configuration or firmware change.

Facts checked against Baker Hughes Bently Nevada pages and published company history, October 2026.

Frequently Asked Questions

What is included in 288055-01?
The datasheet lists it as the standard Transient Data Interface module with a USB cable. The cable part number given in the same table is 123M4610.
Why is a special USB cable required?
The manufacturer states this cable maintains isolation between chassis and ground. Using the wrong cable, or a computer connected to mains ground, can create a ground loop.
Does 288055-01 include the I/O module?
No. An Ethernet I/O module such as 146031-01 or 146031-02 is ordered separately and fitted in the rear slot behind the TDI.
Is it the same electrically as 138607-01?
Both are described as standard-type 3500/22M modules. The 288055-01 listing adds the USB cable. Check the board label against your stored configuration.
Where does the TDI sit in the rack?
It always occupies Slot 1, the full-height slot next to the power supplies, with its I/O module in the matching rear slot.