Brand: PULS
PULS UF20.241 24V 20A Capacitor Buffer Module 200 ms
Description
A maintenance-free buffer module that rides through short 24 V dips
The PULS UF20.241 is a buffer module for regulated 24 V power supplies. Instead of lead-acid batteries it stores energy in service-free electrolytic capacitors, which is why the datasheet allows operation at ambient temperatures up to +70 C. It can be used to bridge failures of the DC voltage supply, to extend the hold-up time after loss of AC power, or to deliver extra short-term peak current above the current rating of the power supply. No control wiring is required: the module is connected in parallel to the load circuit at any point in the 24 V system.
The buffer module is rated for 20 A buffer current and gives at least 200 ms of buffering at 20 A, longer at lower loads. Several modules can be paralleled to increase either the current or the hold-up time. For multi-minute bridging use a battery-based DC-UPS such as the UB10.241 on this site.
Technical specification
| Parameter | Specification |
|---|---|
| Order number | UF20.241 (buffer module, UF-Series, 24 V, 20 A) |
| Supply voltage | DC 24 V, -20 % / +25 % (19.2 to 30 Vdc) |
| Voltage to charge capacitors | typ. 23 Vdc |
| Buffer threshold | Selectable: 22.5 V fixed or supply voltage minus 1 V; buffering starts when the supply falls by more than 1 V |
| Buffer current | 20 A minimum; electronically limited on overload, buffering stops and the capacitors are discharged below 17 V |
| Buffer time | min. 200 ms at 22.5 V and 20 A; min. 430 ms at 10 A; typ. 310 ms at 20 A; typ. 670 ms at 10 A; typ. 43 s at 0.1 A |
| Charging time | typ. 25 s initial charging; typ. 18 s recharging shortly after a buffer event |
| Current consumption | typ. 80 mA in stand-by (capacitors charged); max. 600 mA during charging |
| Power dissipation / efficiency | 1.9 W in stand-by; efficiency above 99 % in power supply mode at 20 A |
| Protection | Reverse polarity protection (max. -35 V); IP20; inhibit input to disable or interrupt buffering |
| Signals | Status LED (slow flash at 1.25 Hz while charging) and signalling terminals with opto-coupler outputs (0.9 V at 1 mA, 3 V at 5 mA) |
| Terminals | Power: spring-clamp, max. 6 mm2 solid, 4 mm2 stranded, 10 mm stripping; signals: pluggable screw terminals, max. 2.5 mm2, 6 mm stripping |
| Environment | -25 C to +70 C operating; 5 to 95 % r.H.; vibration 2-17.8 Hz plus/minus 1.6 mm, 17.8-500 Hz 2 g; shock 30 g 6 ms and 20 g 11 ms; altitude to 6000 m (approvals up to 2000 m) |
| Dimensions / weight | 64 x 124 x 102 mm (W x H x D); 740 g |
| MTBF | 2 327 000 h (SN 29500) in stand-by at 40 C |
| Approvals on cover page | UL 508 and UL 60950-1; IEC 60950-1 CB certificate listed in chapter 22; install according to Class III rules |
Choosing between a buffer module and a battery DC-UPS
Typical mains dips in industrial plants last from a few milliseconds to a second or two. A capacitor buffer module covers that window without any battery maintenance. At 10 A the datasheet gives typically 670 ms and at 20 A about 310 ms, and the figure rises sharply for light loads, 43 seconds typical at 0.1 A. Battery-based DC-UPS units cover minutes to hours, but need battery replacement every few years. In hot GCC installations capacitors tolerate the temperature better than lead-acid batteries. The module also helps with peak loads: it can supply short current pulses above the rating of the main power supply, which is useful for motor starters and solenoid groups.
Installation notes
- Connect in parallel to the 24 V rail, close to the power supply output; no control wiring is needed.
- Use the selectable threshold: 22.5 V suits most loads, while the supply-minus-1 V option follows an adjusted rail voltage.
- Use the inhibit input if buffering must be disabled during service work.
- Allow the 25 s initial charging time at start-up before expecting buffer function.
- Accessories in the order list: ZM1.WALL panel bracket and ZM14.SIDE side bracket; the datasheet also lists UF20 as accessory for the XT40 and QT40 supplies.
GCC use cases
Buffer modules prevent nuisance PLC resets when large motors start on weak or generator-fed networks and when the upstream supply switches between sources. They are common in pumping stations, compressor houses and utilities where grid disturbances are frequent. See the Power Modules category for supplies and redundancy modules that pair with the UF20.241.
Selection and installation notes
A redundancy or buffer module is selected from the load current, the output voltage and the way the supplies are arranged. Size each supply so one can carry the whole load, keep the wiring from each supply equal in length and cross-section, check the polarity and the module rating against the maximum load and test the changeover by switching one supply off. Allow the heat dissipation and the clearances on the data sheet.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Datasheets & Documents
- Datasheet PULS UF20.241 datasheet (May 2023, Rev. 2.1) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
PULS is a German manufacturer of DIN-rail power supplies for industrial automation, founded in Munich in 1980 by power supply engineer Bernhard Erdl, who leads it as CEO and chief developer. The company has focused only on industrial applications and helped make DIN-rail mounting, power reserves and wide operating temperature ranges standard features. PULS produces in the Czech Republic, China and Germany.
Seven Star LLC is an independent supplier in Muscat. We list PULS power supplies and supplementary modules for PLC cabinets, pumping stations, compressor packages and utility panels in Oman and the GCC.
PULS company profile
| Founded | 1980, Munich, by Bernhard Erdl |
|---|---|
| Headquarters | Munich, Germany |
| Production | Chomutov (Czech Republic), Suzhou (China), Drebach (Germany) |
| Focus | Industrial power supplies only |
| Product families | DIMENSION CP, QS, QT and XT DIN-rail power supplies, CS series, PIANO and MiniLine supplies, redundancy modules, buffer and DC-UPS modules |
Milestones
- 1980: Bernhard Erdl founds PULS in Munich.
- 1997: PULS commits to the DIN-rail concept.
PULS product series
DIMENSION power supplies on this site include the CP10.241 (24 V, 10 A), the CS10.241 with auto-select input, the QS20.241 (24 V, 20 A) and the three-phase CT5.241, QT40.241 and semi-regulated XT40.241 for 40 A. Higher-featured models offer PowerBoost or BonusPower reserves and a DC-OK signal.
Supplementary units include the MLY10.241 dual diode redundancy module, the YR40.242 MOSFET redundancy module for 40 A, the UF20.241 capacitor buffer module that bridges supply interruptions of about 200 ms, and the UB10.241 DC-UPS control unit used with batteries.
Where PULS power supplies are used
24 V supply for PLCs, I/O, sensors and actuators in machine and process control panels, redundant supplies for critical systems, and buffered supplies for controllers that must ride through short mains dips.
PULS products we list
Ordering PULS products: what we need
Send the full order code, such as QS20.241, together with the input voltage and phases, output current, ambient temperature and any approvals required, such as UL, marine, ATEX, IECEx or Class I Div 2, which apply only to selected models.
Facts checked against PULS company profiles and an interview with Bernhard Erdl, October 2026.
Browse PULS products by category: Power Modules.
Related products
Frequently Asked Questions
At least 200 ms at 22.5 V and 20 A according to the datasheet; typically about 310 ms.
No, it stores energy in service-free electrolytic capacitors, so no battery replacement is needed.
No. It is connected in parallel to the load and has optional signalling terminals and an inhibit input.
Yes, the datasheet states that buffer modules can be connected in parallel to increase the current or the hold-up time.
No, Seven Star LLC is an independent supplier in Muscat. Send us your load current and required ride-through time.


















Reviews