Raytec SPX-WL84-EMX25 SPARTAN Linear WL84 Zone 1 Emergency LED

Description

SPX-WL84-EMX25 is the SPARTAN Linear WL84 Zone 1/21 LED luminaire with the EMX25 intelligent emergency option: 80 LEDs, about 3,065 lm on mains, and a self-testing battery that gives up to 3 hours at 25 percent power.

A fluorescent-tube replacement that is certified for hazardous areas

SPARTAN Linear has been designed with the same dimensions, fixing centres and cable entries as traditional fluorescent fittings, so it is a direct replacement in refineries, platforms and process buildings. The WL84 is the shorter body, 761 mm long on the datasheet sketch, with 80 LEDs and 24 W on mains (32 W for the emergency version).

The code is built from the datasheet part code builder: SPX is the Zone 1/21 family, WL84 the model, EMX25 the emergency option (25 percent output for 3 hours), with 6500 K, standard optics, 110 to 254 V and M20 entries left unstated because they are defaults. The marine-grade aluminium and UV-stabilised polycarbonate body has stainless fasteners, and key parts are accessible for maintenance under the modular design.

Key features as printed in the datasheet

  • Self-testing intelligent emergency with a tri-colour system health indicator; up to 3 hours at 25 percent power, Ni/Cd 12 V battery, 20 hour charge time.
  • Ex eb mb IIC T4 Gb for gas and Ex tb IIIC T80 degrees C Db for dust, as printed on the datasheet.
  • IP66 and IP67, IK10 impact rating, ABS certificate number 25-0220600-PDA.
  • DALI 2.0 is offered on non-emergency variants only, so it is not an option with EMX25.

Technical specification

Certification as printed

Parameter Specification
Hazardous area rating Zone 1 (gas), Zone 21 (dust); ATEX, UKEX and IECEx
Certificates CML14ATEX3119, IECExCML15.0001, CML21UKEX3105
Marking (gas) II 2 G; Ex eb mb IIC T4 Gb; Ta -40 °C to +60 °C (-20 °C to +50 °C for emergency variants); T6 variants available, contact Raytec
Marking (dust) Ex tb IIIC T80 °C Db; Ta -40 °C to +60 °C (-20 °C to +50 °C for emergency)
Other ABS certificate #25-0220600-PDA; IP66 and IP67; IK10

Electrical and optical (WL84 emergency)

Parameter Specification
Order code (this page) SPX-WL84-EMX25 – WL84 with 25 percent, 3 hour emergency
Power 32 W (24 W non-emergency)
Input Standard 110-254 V 50/60 Hz AC/DC, optional 110-277 V; see datasheet for emergency and low-voltage versions (18-48 V AC, 18-69 V DC)
Power factor Above 0.95
Cable entries 2 x M20 at each end, 4 in total; three ATEX/IECEx/UKEX blanking plugs supplied
LEDs / CRI / colour temperature 80 Platinum Elite SMT LEDs / 80+ / 6500 K standard
Lumen output, standard optic 3,065 lm on mains
Termination Terminal block for looping 4 core 4 mm² cable (6 mm² available at extra cost)

Mechanical and emergency

Parameter Specification
Weight 7 kg (15.4 lb) for the emergency version
Length x width x height 761 x 174 x 109 mm (sketch values, 30 x 6.9 x 4.3 in); mounting points at 200 mm centres
Enclosure Marine-grade aluminium, epoxy powder coated, UV-stabilised polycarbonate, stainless fasteners
Colour Silver RAL 9006 with red RAL 3024 emergency battery cover
Mounting M8/M6 tapped holes; various arrangements, see product overview guide
Emergency duration / battery Up to 3 hours at 25 percent power / Ni/Cd 12 V; 20 hour charge
Sustainability EPD HUB-3730 verified by EPD Hub; TM66 circularity score 2.0

Lumen output by optic (WL84)

Parameter Specification
Standard / 60 x 60 / 90 x 90 3,065 lm / 2,980 lm / 2,984 lm
Diffused / PP3 / WB 2,759 lm / 2,994 lm / 2,980 lm

Reading the part code and choosing options

The datasheet part code builder gives these fields: model WL84, WL168, WL84-1200 or WL168-1500; emergency EMX25 or DA for DALI; variant T6; CCT 4K; optics; LV or 277 for voltage; and entry M25. For this code only the model and emergency option are stated. The longer WL168 gives 6,130 lm and 49 W on mains; the WL84-1200 and WL168-1500 are longer bodies of 1,311 mm and 1,650 mm.

The Essential versions (WL84-LL, WL168-LL) have two M20 entries at one end and no emergency option. Safety shower (green, 519 nm) and wildlife-friendly (amber, 600 nm) specials are listed separately with example codes SPX-WL168-G and SPX-WL168-4K-A. Confirm voltage, emergency duration and mounting before ordering.

Installation, battery and maintenance notes

Raytec cites installation guide 0920-D-00042 and battery care document 0010-D-00001 for this product, and a Linear mounting and accessories guide for brackets. The emergency battery needs 20 hours to charge before the duration rating is reached, and the datasheet temperature range for emergency variants narrows to -20 to +50 °C.

Because the gland entries are ATEX-approved blanking plugs, only certified cable glands and stopping plugs may be used in the open entries. Follow the certificate conditions and the installation guide; this page does not replace them.

Applications in Oman and the GCC

Typical uses are refinery and gas plant buildings, offshore support platforms, tank farm pump houses, battery rooms and process units where Zone 1/21 classification applies. The emergency version provides local escape lighting from the same fitting. The IP66/IP67 rating helps in dust and washdown.

Compatible accessories and related items

Related items are the Linear mounting accessories, Essential versions, DALI controls on non-emergency variants and the SPARTAN Bulkhead and Flood luminaires. See the category page for other Raytec lighting.

Frequently asked questions

What does EMX25 mean?

An intelligent self-testing emergency option giving up to 3 hours at 25 percent power.

Is it certified for Zone 1?

The datasheet states Zone 1 gas and Zone 21 dust with ATEX, UKEX and IECEx certificates CML14ATEX3119, IECExCML15.0001 and CML21UKEX3105.

How many lumens does the WL84 give?

About 3,065 lm on mains with the standard optic.

Can I add DALI to this code?

No; DALI 2.0 is offered only on non-emergency, non-low-voltage variants.

Is Seven Star LLC a Raytec distributor?

No. Seven Star LLC is an independent supplier in Muscat that sources Raytec products on request.

Documents and quotation

Download the official Raytec datasheet for SPX-WL84-EMX25 from this page. As an independent supplier based in Muscat, Seven Star LLC supplies Raytec items on request: use the quote form with the quantity you need. Check every value in the document against your own specification before you order. Browse similar items in the category.

Datasheets & Documents
  • PDF Datasheet Raytec SPARTAN Linear Zone 1 datasheet 0920-D-00048 rev 11 (PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Raytec is a British manufacturer of LED lighting for security, hazardous area, industrial and transport applications, incorporated on 10 August 2005 and based in Ashington, Northumberland, with an office in Ottawa, Canada. It is best known for its VARIO infrared and white-light illuminators for CCTV, and launched a hazardous area division in 2013.

Seven Star LLC is an independent supplier in Muscat. We list Raytec hazardous-area luminaires and CCTV illuminators with the official datasheet beside each listing, for oil and gas, security and transport projects in Oman and the GCC.

Raytec company profile

Founded 2005, Ashington, England
Headquarters Ashington, Northumberland; office in Ottawa, Canada
Divisions Security, Hazardous, Industrial and Transport
Product families VARIO2 infrared and white-light illuminators, VARIO2 IP network illuminators, PULSESTAR pulsed IR for ANPR and traffic, SPARTAN hazardous area lighting, RAYLUX industrial lighting

Milestones

  • 2005: Raytec Limited is incorporated.
  • 2013: Raytec launches its hazardous area division.

Raytec product series

SPARTAN hazardous-area luminaires, certified to ATEX, IECEx and UKEX, include the BL24 bulkhead for zone 1, the SL96 street light for zone 1 and 21, the WL84 linear light with emergency battery and the HPFL300 high-power floodlight for zone 1.

For CCTV, the VARIO2 range includes the Lite i6 and Extreme i16 infra-red illuminators, the network-connected iP PoE i8 and the w8 white-light double panel. PULSESTAR pulsed illuminators, such as the PSTR-i48 and the VTS20, are designed for ANPR and traffic cameras.

Where Raytec lighting is used

Process areas, tank farms and offshore platforms in hazardous zones, perimeter and site security with CCTV at night, and number plate recognition at gates, car parks and roads.

Raytec products we list

Family Examples
CCTV & Security PSTR-i48-HV PULSESTAR i48 Pulsed IR Illu…, VAR2-IPPOE-i8-1 VARIO2 iP PoE i8 IR Netw…, VAR2-LTE-i6-1 VARIO2 Lite i6 Infra-Red I…, VAR2-w8-2 VARIO2 White Light Double Pane…, VAR2-XTR-i16-1 VARIO2 Extreme i16 IR Ill…, VTS20-850-28-ETH PULSESTAR VTS20 Pulsed…

Ordering Raytec products: what we need

Send the Raytec part number. For SPARTAN luminaires state the zone and gas group, voltage, light output, mounting and whether emergency backup is needed; for illuminators state the camera type, required distance and angle, IR wavelength or white light, and power supply.

Facts checked against Companies House records and Raytec company profiles, October 2026.

Frequently Asked Questions

What does EMX25 mean?
An intelligent self-testing emergency option giving up to 3 hours at 25 percent power.
Is it certified for Zone 1?
The datasheet states Zone 1 gas and Zone 21 dust with ATEX, UKEX and IECEx certificates CML14ATEX3119, IECExCML15.0001 and CML21UKEX3105.
How many lumens does the WL84 give?
About 3,065 lm on mains with the standard optic.
Can I add DALI to this code?
No; DALI 2.0 is offered only on non-emergency, non-low-voltage variants.
Is Seven Star LLC a Raytec distributor?
No. Seven Star LLC is an independent supplier in Muscat that sources Raytec products on request.