Brand:

Lenze i550-C7.5/400-3 Cabinet Frequency Inverter

Description

Modular 7.5 kW inverter for conveyors, hoists and machines

The Lenze i550-C7.5/400-3 is a control cabinet frequency inverter from the Lenze i500 series, rated 7.5 kW (10 hp) in heavy duty on a three-phase 400/480 V supply. The i550 is the modular member of the series: it is built from a power unit, a control unit with the chosen I/O and fieldbus, and an optional safety unit. Lenze lists conveyor, travelling, winding and hoist drives, extruders, packaging machines, pumps and fans as typical applications.

Because the parts plug together without tools, a machine builder can stock one power unit and fit different control units for different machines. For a fixed application, the inverter can also be ordered as a complete device.

Technical specifications

Values from the Lenze i500 brochure (08.2018) for the 480 V i550 range.

Parameter Specification
Type i550-C7.5/400-3
Power unit order code I5DAE275F10V10000S
Rated power, heavy duty 7.5 kW (10 hp); rated output current 16.5 A
Rated power, light duty 11 kW (15 hp); rated output current 23 A
Mains connection 3/PE AC 340 V to 528 V, 45 to 65 Hz; integrated RFI filter
Overload capacity 200% for 3 s; 150% for 60 s (heavy duty), 120% for 60 s (light duty)
Switching frequency 2, 4, 8 or 16 kHz
Output frequency 0 to 599 Hz
Ambient temperature up to 55 °C with derating of 2.5%/K above 45 °C
Enclosure IP20 (EN 60529)
Dimensions (H x W x D) 276 x 120 x 130 mm
Weight 3.7 kg
Approvals and conformity CE, EAC, RoHS 2; UL 61800-5-1, CSA 22.2 No. 274; IE2 to EN 50598-2

Control modes, I/O and fieldbus options

The i550 supports V/f control (linear, square-law and VFC eco energy saving), sensorless vector control, sensorless control of synchronous motors and servo control of asynchronous motors with HTL encoder feedback. A brake chopper is integrated, and DC bus connection is possible on the 480 V devices. Lenze offers standard I/O (5 digital inputs, 1 digital output, 2 analog inputs, 1 analog output, relay) or application I/O with more channels. Fieldbus options include CANopen, Modbus RTU and TCP, POWERLINK, EtherCAT, EtherNet/IP, PROFIBUS and PROFINET.

Safe Torque Off is available as an option and is rated by Lenze to SIL 3 (EN IEC 61508) and PL e (EN ISO 13849-1). Commissioning and diagnostics are possible through the keypad, USB or a WLAN module, and parameters are stored on a plug-in memory module, which simplifies replacing a unit.

Sizing and installation notes

Choose between heavy and light duty by the load: hoists and conveyors starting under load usually need the 150% overload of heavy duty, while fans and centrifugal pumps can use the higher light-duty current. The rated currents apply at 45 °C with 2 or 4 kHz switching frequency, or 40 °C at 8 or 16 kHz. For EMC category C2, Lenze gives a motor cable length of up to 20 m. Units can be mounted side by side in the cabinet.

How the Lenze i550-C7.5/400-3 Frequency Inverter Works

A frequency inverter controls the speed and torque of an AC motor by changing the frequency and voltage it receives. In the i550-C7.5/400-3, the three-phase mains supply is rectified into a DC bus, smoothed by capacitors, and then switched by IGBT power transistors to produce a variable-frequency output using pulse width modulation. Because motor speed follows frequency, the drive can run the motor at any speed within its range, ramp smoothly up and down, and limit current during start-up.

When a load drives the motor faster than the set speed, such as a lowering hoist or a decelerating conveyor, the motor acts as a generator and returns energy to the DC bus. The integrated brake chopper switches this energy to an external brake resistor, which must be sized for the duty.

Energy Savings on Pumps and Fans

For centrifugal pumps and fans, required power falls steeply as speed is reduced. Replacing throttling valves or dampers with speed control is therefore one of the most effective ways to reduce energy use. The square-law and VFC eco modes of the i550 are intended for this kind of load.

Selection & Ordering Guide for the i550-C7.5/400-3

  • Compare the motor rated current with the inverter output current for heavy or light duty.
  • Choose the control unit by I/O count and fieldbus needed.
  • Add Safe Torque Off if the machine safety concept requires it.
  • Plan the brake resistor, mains choke or filter, and motor cable according to the application.

Our team can help confirm the correct ordering code.

Installation & Maintenance

  • Install in a ventilated cabinet and allow for the temperature derating in hot climates.
  • Use shielded motor cable with 360° shield connection for EMC compliance.
  • Fit mains fuses or circuit breakers as specified in the Lenze documentation.
  • Keep a copy of the parameter set on the memory module and in a backup file.
  • Clean dust from heatsinks and check cabinet fans and filters regularly.

Motor Control Modes Explained

V/f control is the simplest mode and suits pumps, fans and many conveyors. Sensorless vector control estimates the motor flux and torque from current measurements, giving better torque at low speed and more precise speed holding under changing loads, which helps with conveyors starting under load and mixers. Servo control with encoder feedback offers the most accurate speed and position response for demanding motion tasks. Choosing the right mode and running motor identification during commissioning improves drive performance.

Typical Applications in Oman & the GCC

The i550-C7.5/400-3 suits conveyors, pumps, fans, cooling towers, mixers, packaging machines and hoists in factories, water utilities and building services across Oman and the GCC.

Why Source from Seven Star LLC

Seven Star LLC supplies Lenze drives across Oman and the GCC. Request a quote with your order code and motor data.

Documents and quotation

The attached Lenze i500 brochure covers the i510 and i550 ranges, ratings tables and order codes. It dates from 2018, so confirm current codes before ordering. For a quotation, state the complete order code or the type plus I/O, fieldbus and STO requirements, and the motor data. More drives are listed under AC Drives.

Datasheets & Documents
  • PDF Brochure Lenze i500 inverters brochure (EN-US, 08/2018) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Lenze is the German drive and automation company for machine building: frequency inverters, servo inverters, motors and gearboxes, controllers and engineering software. Its history begins on 5 November 1947, when Hans Lenze took over Stahlkontor GmbH in Hameln from the Mannesmann group. The group is led by Lenze SE, an unlisted European company based in Aerzen near Hameln, and the Lenze family owns all of its shares.

Seven Star LLC is an independent supplier in Muscat. We list Lenze frequency and servo inverters, including current and earlier generations, for machine builders and maintenance teams in Oman and the GCC.

Lenze company profile

Founded 5 November 1947, Hameln, Germany, when Hans Lenze (1890–1963) took over Stahlkontor GmbH
Headquarters Aerzen, Lower Saxony, Germany
Ownership Lenze SE, unlisted; 100% family-owned
First inverter Lenze's first frequency inverter for three-phase AC motors, 1977
Product families 8200 vector, 8400, i500 and i950 inverters, servo drives, MCS and MF motors, g500 gearboxes, controllers, I/O and communication modules, EASY engineering software

Milestones

  • 1947: Hans Lenze takes over Stahlkontor GmbH in Hameln on 5 November.
  • 1977: The first Lenze frequency inverter for three-phase AC motors is launched.
  • 1999: Lenze acquires AC Tech in the USA.
  • 2009: Lenze AG becomes Lenze SE.

Lenze product series

Current inverters on this site are the i500 family: the i510 compact frequency inverter, the i550 cabinet inverter and its i550 protec decentral version for mounting on the machine, and the i950 cabinet servo inverter. Earlier generations that are still widely installed are also listed: the 8400 StateLine C inverters (E84AVSC...), the 8200 vector frequency inverters (E82EV...) and the 9300 servo position controllers and servo inverters (EVS93...), including versions with Safe Torque Off.

Where Lenze drives are used

Conveyors and intralogistics, packaging and bottling lines, pumps and fans, hoists, textile and printing machines, and positioning axes on special machines. Many plants in the region keep 8200 vector and 9300 drives in service and need exact replacements or a planned migration to the i500 series.

Lenze products we list

Family Examples
AC Drives E82EV113K4C 8200 vector Frequency Inverter 11, E82EV222K2C 8200 vector Frequency Inverter, E82EV551K2C 8200 vector Frequency Inverter, E82EV752K4C 8200 vector Frequency Inverter, E84AVSCE2224SB0 8400 StateLine C Inverter 2.2, E84AVSCE3712SX0 8400 StateLine C Inverter, E84AVSCE5514SB0 8400 StateLine C Inverter, E84AVSCE5524SX0 8400 StateLine C Inverter 5.5 and 5 more
Servo Drives EVS9321-EP 9300 Servo Position Controller, EVS9322-EP 9300 Servo Position Controller, EVS9323-EP 9300 Servo Position Controller 1.5, EVS9324ESV004 9300 Servo Inverter 3.0 kW with, i950-C7.5/400-3 Cabinet Servo Inverter
Automation Accessories E82ZAFSC Standard I/O Function Module for, EMF2102IBCV001 LECOM-A/B Communication Module, EMF2133IB PROFIBUS-DP Communication Module

Ordering Lenze inverters: what we need

Send the complete type code from the nameplate, for example E84AVSCE5524SX0, together with the supply voltage, motor power and current, the control interface or fieldbus module, and any options such as safety functions, keypad or brake resistor. When replacing an installed drive, keep the parameter set and wiring records, because a new unit or a successor model must be parameterised to match the machine.

Frequently requested Lenze models: Lenze EVS9324-ES 9300 Servo Inverter 3.0 kW.

Facts checked against Lenze's published company history, October 2026.

FAQ

Questions about the Lenze i550-C7.5/400-3 Cabinet Frequency Inverter

Answers from our engineering team on installation, compatibility and integration.

01What is the rated current of the i550-C7.5/400-3?
16.5 A at 7.5 kW in heavy duty, or 23 A at 11 kW in light duty, according to the Lenze i500 brochure.
02Which supply does it need?
Three-phase 340 V to 528 V, 45 to 65 Hz. The 480 V devices include an integrated RFI filter.
03Is Safe Torque Off included?
STO is an option. Lenze rates it to SIL 3 and PL e when the safety unit is fitted.
04Can the i550 be ordered as separate parts?
Yes. It can be ordered as a complete device or as power unit, control unit and safety unit. The power unit code is I5DAE275F10V10000S.
05Which fieldbuses are available?
CANopen, Modbus RTU and TCP, POWERLINK, EtherCAT, EtherNet/IP, PROFIBUS and PROFINET, depending on the control unit.