Brand:

Lenze E82EV402K4C 8200 vector Frequency Inverter 4.0 kW 400 V

Description

Lenze 8200 vector at 4.0 kW, 400 V

If a 4.0 kW (5.4 hp) induction motor has to run from a 3/PE 400 V supply, the Lenze E82EV402K4C is the 8200 vector frequency inverter that the catalogue assigns to that rating. The base controller holds the power stage; function modules and a keypad are added to it. Note that the 8200 vector sits under previous products on the Lenze website. Ratings come from the 11/02 Lenze catalogue, an older edition, and should be verified with the supplier before an order is placed.

Technical specifications

Parameter Specification
Type E82EV402K4C
Product range Lenze 8200 vector base controller
Typical motor power 4.0 kW (5.4 hp)
Mains voltage 3/PE 320 V to 550 V AC, 45 to 65 Hz
Mains current, no choke / choke 12.3 A / 8.8 A
DC supply 450 V to 775 V DC
Apparent output power, 8 kHz 6.6 kVA
Rated output current 9.5 A
Rated current at 16 kHz 6.1 A
Maximum current, 60 s 14.2 A (16 kHz: 9.1 A)
Power loss at 8 kHz 180 W
Frequency range of output 0 to 650 Hz, both rotation directions
Chopper frequency 2 / 4 / 8 / 16 kHz
Degree of protection IP20
Dimensions H x W x D 240 x 100 x 140 mm
Weight 2.9 kg
Approvals as printed CE to low voltage directive 73/23/EEC and UL 508C (File No. E132659)

Reading the type code E82EV402K4C

Breaking the code down: E82EV means 8200 vector base controller; 402 stands for the 4.0 kW rating; K4C is the 400 V supply class. The stem alone does not say whether an EMC filter is built in: suffix 0xx does, 2xx does not, and the catalogue prints both.

Choosing and installing this size

Most installations combine it with function module E82ZAFSC010 as the I/O interface and may add the EMZ9371BC keypad. Always compare the motor’s rated current with 9.5 A, because kW alone can mislead. Raising the chopper frequency to 16 kHz limits the current to 6.1 A. A mains choke is optional and lowers the mains current to 8.8 A. Above +40 degrees C reduce the rated current by 2.5% per degree, and above 1000 m altitude by 5% per 1000 m. Install it in vertical position and leave a 100 mm gap above and below the housing.

The catalogue’s control data apply to every size. The controller offers V/f characteristic control, linear or quadratic, as well as vector control with torque provision. Maximum torque is 1.8 times the rated motor torque for 60 s when the motor rating equals the drive rating. In sensorless speed control the setting range is 1:50 related to 50 Hz and rated torque, with an accuracy of plus or minus 0.5 percent and a minimum output frequency of 1.0 Hz. Digital setpoints are accurate to plus or minus 0.005 Hz, and the analog inputs use a 10-bit converter. At 4.0 kW these figures combine with the 9.5 A rating above.

Where it sits in the range

Neighbours in the 400 V class are given by the type tables: the next size down is 3.0 kW (E82EV302K4C) and the next size up is 5.5 kW (E82EV552K4C).

Documentation and quotation

Ratings, mounting drawings and accessories are in the attached Lenze catalogue, edition 11/02, which should be checked against the nameplate. More inverters are shown in AC Drives. Quote requests need the whole part number with suffix, the voltage and motor nameplate details; availability should be confirmed before ordering.

Datasheets & Documents
  • PDF Catalogue Lenze 8200 vector catalogue FU 8200 vector en 11/02 (Lenze document, older edition) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Lenze is the German drive and automation company for machine building: frequency inverters, servo inverters, motors and gearboxes, controllers and engineering software. Its history begins on 5 November 1947, when Hans Lenze took over Stahlkontor GmbH in Hameln from the Mannesmann group. The group is led by Lenze SE, an unlisted European company based in Aerzen near Hameln, and the Lenze family owns all of its shares.

Seven Star LLC is an independent supplier in Muscat. We list Lenze frequency and servo inverters, including current and earlier generations, for machine builders and maintenance teams in Oman and the GCC.

Lenze company profile

Founded 5 November 1947, Hameln, Germany, when Hans Lenze (1890–1963) took over Stahlkontor GmbH
Headquarters Aerzen, Lower Saxony, Germany
Ownership Lenze SE, unlisted; 100% family-owned
First inverter Lenze's first frequency inverter for three-phase AC motors, 1977
Product families 8200 vector, 8400, i500 and i950 inverters, servo drives, MCS and MF motors, g500 gearboxes, controllers, I/O and communication modules, EASY engineering software

Milestones

  • 1947: Hans Lenze takes over Stahlkontor GmbH in Hameln on 5 November.
  • 1977: The first Lenze frequency inverter for three-phase AC motors is launched.
  • 1999: Lenze acquires AC Tech in the USA.
  • 2009: Lenze AG becomes Lenze SE.

Lenze product series

Current inverters on this site are the i500 family: the i510 compact frequency inverter, the i550 cabinet inverter and its i550 protec decentral version for mounting on the machine, and the i950 cabinet servo inverter. Earlier generations that are still widely installed are also listed: the 8400 StateLine C inverters (E84AVSC...), the 8200 vector frequency inverters (E82EV...) and the 9300 servo position controllers and servo inverters (EVS93...), including versions with Safe Torque Off.

Where Lenze drives are used

Conveyors and intralogistics, packaging and bottling lines, pumps and fans, hoists, textile and printing machines, and positioning axes on special machines. Many plants in the region keep 8200 vector and 9300 drives in service and need exact replacements or a planned migration to the i500 series.

Lenze products we list

Family Examples
AC Drives E82EV113K4C 8200 vector Frequency Inverter 11, E82EV222K2C 8200 vector Frequency Inverter, E82EV551K2C 8200 vector Frequency Inverter, E82EV752K4C 8200 vector Frequency Inverter, E84AVSCE2224SB0 8400 StateLine C Inverter 2.2, E84AVSCE3712SX0 8400 StateLine C Inverter, E84AVSCE5514SB0 8400 StateLine C Inverter, E84AVSCE5524SX0 8400 StateLine C Inverter 5.5 and 5 more
Servo Drives EVS9321-EP 9300 Servo Position Controller, EVS9322-EP 9300 Servo Position Controller, EVS9323-EP 9300 Servo Position Controller 1.5, EVS9324ESV004 9300 Servo Inverter 3.0 kW with, i950-C7.5/400-3 Cabinet Servo Inverter
Automation Accessories E82ZAFSC Standard I/O Function Module for, EMF2102IBCV001 LECOM-A/B Communication Module, EMF2133IB PROFIBUS-DP Communication Module

Ordering Lenze inverters: what we need

Send the complete type code from the nameplate, for example E84AVSCE5524SX0, together with the supply voltage, motor power and current, the control interface or fieldbus module, and any options such as safety functions, keypad or brake resistor. When replacing an installed drive, keep the parameter set and wiring records, because a new unit or a successor model must be parameterised to match the machine.

Facts checked against Lenze's published company history, October 2026.

Frequently Asked Questions

What motor power is the E82EV402K4C rated for?
The Lenze catalogue assigns E82EV402K4C to a 4.0 kW (5.4 hp) four-pole motor on a 400 V class supply.
What is the rated output current of the E82EV402K4C?
9.5 A at up to 8 kHz chopper frequency, 6.1 A at 16 kHz, with 14.2 A allowed for 60 s.
Is the E82EV402K4C a current Lenze product?
Lenze lists the 8200 vector under previous products. Confirm availability and any replacement with the supplier before ordering.
Which function module does the E82EV402K4C need?
The catalogue quick-selection guide pairs it with the Standard I/O PT function module E82ZAFSC010 for terminal control.
What does the suffix on the E82EV402K4C type code mean?
The catalogue uses 0xx for versions with an integrated EMC filter and 2xx for those without, so confirm the suffix on your quotation.