Brand: Applied Analytics
Applied Analytics OMA BTX Analyzer
Description
Overview
The Applied Analytics OMA BTX Analyzer is a continuous process analyzer purpose-built to quantify benzene, toluene, xylene, and related aromatic hydrocarbons directly in gas or liquid process streams, using dispersive UV-Vis absorbance spectrophotometry rather than slower gas-chromatography-based methods. Aromatic hydrocarbons display distinctive, strong absorption in the 200-300 nm spectral region, and the OMA BTX Analyzer’s nova II diode-array spectrophotometer resolves that signature continuously, giving fuel blending, solvent, adhesive, and detergent manufacturers a real-time compliance tool for regulated carcinogenic aromatic content.
Seven Star LLC supplies the OMA BTX Analyzer to petrochemical and fuel-blending operators across Oman and the wider GCC, with manufacturer documentation and technical support with selection. Refineries and specialty chemical producers in the Sultanate of Oman gain a regional point of contact for commissioning, application support, and after-sales service rather than relying solely on overseas manufacturer channels.
Operating Principle
The Applied Analytics OMA BTX Analyzer passes light from a pulsed xenon lamp through the sample and captures the resulting spectrum across the 200-800 nm range with a diode-array detector, with particular analytical weight placed on the 200-300 nm band where benzene, toluene, and xylene each display characteristic, well-separated absorbance peaks. Proprietary mathematical de-convolution routines resolve the individual concentration of each aromatic component from the composite spectrum, delivering a continuous reading every 1-5 seconds across a dynamic range spanning roughly 0-10 ppm up to 0-100% concentration depending on the application.
Because the measurement is entirely optical, the OMA BTX Analyzer avoids the sample-preparation steps, carrier-gas consumption, and cycle-time delay inherent to gas-chromatography BTX analyzers, while still delivering laboratory-grade component resolution. With no moving parts in the optical path and a sample-handling capability rated up to 150°C and 3000 psi in the standard configuration, the analyzer can be installed directly on hot, pressurized process streams without an extensive sample-conditioning skid, reducing both capital cost and the maintenance burden of a conventional extractive BTX analyzer system.
Engineering Design of the Applied Analytics OMA BTX Analyzer
The Applied Analytics OMA BTX Analyzer is built on the same rugged OMA platform enclosure family as other Applied Analytics process analyzers, available in wall-mounted indoor/outdoor housings rated for ATEX and Class I Division 1/2 hazardous areas, with purged (Eexp) or flameproof cast-aluminum (Eexd) explosion-proof options for installation directly in fuel-blending or aromatics-handling process areas. A 19-inch rackmount version supports analyzer-shelter installations serving multiple sample points across a blending or extraction unit.
The analyzer operates from universal 85-264 VAC power at 47-63 Hz, drawing 45 watts, and communicates through a standard isolated 4-20 mA analog output per measured component, with optional Modbus, HART, and RS-485 digital protocols available for direct integration into a blending control system or laboratory information management system. The onboard ECLIPSE software interface provides operators with live spectral data and trend history for benzene, toluene, and xylene concentrations without requiring a separate PC-based analytical workstation.
Key Features
The Applied Analytics OMA BTX Analyzer platform is engineered around the specific demands of continuous aromatic hydrocarbon compliance monitoring, and its key features include the following:
- Simultaneous continuous measurement of benzene, toluene, xylene, and related aromatic hydrocarbons from a single optical spectrum.
- Dispersive UV-Vis absorbance spectroscopy across 200-800 nm, with analytical focus on the 200-300 nm aromatic absorption region.
- Response time of 1-5 seconds, dramatically faster than the cycle time of a comparable gas-chromatography BTX analyzer.
- Wide dynamic range from roughly 0-10 ppm trace detection up to 0-100% concentration for process and quality-control applications.
- Sample handling rated to 150°C and 3000 psi in the standard configuration, suiting direct installation on hot, pressurized streams.
- ATEX and Class I Division 1/2 certified enclosures, including purged and flameproof explosion-proof variants for fuel and aromatics areas.
- Isolated 4-20 mA analog output plus optional Modbus, HART, and RS-485 connectivity for blending-system integration.
- A totally solid-state optical design with no consumable reagents and no moving parts, minimizing analyzer maintenance downtime.
Industrial Applications
The Applied Analytics OMA BTX Analyzer addresses regulatory and quality-control needs across fuel blending, gasoline and diesel production, adhesives manufacturing, detergent and solvent production, and petrochemical aromatics extraction, wherever carcinogenic aromatic content must be held within strict commercial or environmental limits. Refineries and fuel terminals across Oman and the GCC use continuous BTX monitoring to verify blend-gate benzene specification in real time rather than waiting on periodic laboratory results, reducing the risk of an off-spec batch reaching the market.
Working closely with plant engineers in the region, Seven Star LLC distributes the OMA BTX Analyzer to fuel-blending terminals, petrochemical complexes, and specialty chemical producers throughout Oman and the GCC, including operations based in the Sohar and Salalah industrial and economic zones where aromatics handling and export-grade fuel production continue to expand. Regional customers benefit from local calibration gas supply, spare optical components, and application engineering support alongside genuine Applied Analytics hardware.
Technical Specifications
The table below summarizes the core specifications of the Applied Analytics OMA BTX Analyzer, and this is the standard configuration of the Applied Analytics OMA BTX Analyzer supplied for fuel-blending compliance duty.
| Parameter | Specification |
|---|---|
| Model | Applied Analytics OMA BTX Analyzer |
| Target Analytes | Benzene, toluene, xylene, related aromatic hydrocarbons |
| Measurement Principle | Dispersive UV-Vis absorbance spectrophotometry |
| Detector | nova II UV-Vis diode-array spectrophotometer |
| Wavelength Range | 200-800 nm (focus on 200-300 nm) |
| Light Source | Pulsed xenon lamp, ±5-year average lifespan |
| Response Time | 1-5 seconds |
| Dynamic Range | 0-10 ppm to 0-100% concentration |
| Sample Conditions | Up to 150°C and 3000 psi (standard model) |
| Outputs | 1x isolated 4-20 mA per analyte; optional Modbus, HART, RS-485 |
| Power | 85-264 VAC, 47-63 Hz, 45 W |
Request a Quote for Applied Analytics OMA BTX Analyzer
Fuel-blending and petrochemical engineers across Oman and the GCC can request a formal quotation for the Applied Analytics OMA BTX Analyzer directly from Seven Star LLC, and can confirm current Applied Analytics OMA BTX Analyzer availability and lead time, with full technical datasheets on request and application-specific configuration guidance from our instrumentation division. With fast quotation turnaround and technical support, Seven Star LLC supplies the OMA BTX Analyzer on request, so contact our team today to specify the right aromatics monitoring solution for your process.
Browse the full Applied Analytics range or see more Gas Analyzer Systems products supplied by Seven Star LLC in Oman and the GCC.
Other Models in the Applied Analytics OMA Process Analyzers Range
Seven Star LLC supplies models from the Applied Analytics OMA Process Analyzers range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Applied Analytics OMA Odorant Analyzer | Gas Analyzer Systems | View details |
| Applied Analytics OMA BTX Analyzer | Gas Analyzer Systems | You are viewing this model |
| Applied Analytics OMA Chlorine Analyzer | Gas Analyzer Systems | View details |
Datasheets & Documents
- Datasheet Applied Analytics OMA-300 Process Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Applied Analytics is an American manufacturer of industrial process analyzers, founded in 1994 and based in Burlington, Massachusetts. Its founders set out to apply UV-Vis spectrophotometry, then used mainly in medicine and research, to heavy industry, especially oil and gas. Its OMA analyzers read a full absorbance spectrum of the process stream with a solid-state design, and the company builds the sample conditioning system for each application in the USA.
Seven Star LLC lists Applied Analytics OMA analyzers for H2S, chlorine, BTX, odorant and multi-stream duty, and supplies them to gas plants, refineries and chemical sites in Oman as an independent supplier.
Applied Analytics company profile
| Founded | 1994, USA |
|---|---|
| Headquarters | Burlington, Massachusetts |
| Technology | Full-spectrum UV-Vis and NIR absorbance spectroscopy |
| Manufacturing | Analyzers and sample systems built in the USA |
| Product families | OMA-300 wall-mount, OMA-406R rackmount and OMA-206P portable analyzers for H2S, chlorine, BTX and odorant, TLG-837 tail gas and air demand analyzer, TSA-200 total sulfur analyzer, oil-in-water analyzers |
Applied Analytics OMA analyzers on this page
The manufacturer offers the OMA in three form factors: the wall-mounted OMA-300, the portable OMA-206P and the rackmount OMA-406R. All three are listed here, with application-specific builds of the same platform:
- OMA-300 H2S Analyzer and OMA-300 Multi-Stream Process Analyzer
- OMA Chlorine, BTX and Odorant analyzers
- OMA-300-InGaAs for near-infrared measurements
The company also makes the TLG-837 tail gas analyzer, a sulfur pit gas version of it, and sample conditioning systems designed for each project.
Where Applied Analytics analyzers are used
Typical duties are H2S in sour gas, acid gas and amine treating, sulfur recovery control, chlorine in chlor-alkali and water treatment, aromatics in hydrocarbon and wastewater streams, and mercaptan odorant in distribution gas. These are everyday measurements in GCC gas processing and refining.
Applied Analytics products we list
Ordering an OMA analyzer: what we need
An OMA is configured for one stream, so the manufacturer needs process data before it can confirm a model. Send the stream composition with all components and their ranges, the analytes and measuring ranges, phase, pressure and temperature at the sample point, area classification, available utilities, required outputs and whether a sample conditioning system or shelter is part of the scope. For spares, send the analyzer serial number and the part description.
Facts checked against Applied Analytics company material and industry directory profiles, October 2026.
Browse Applied Analytics products by category: Gas Analyzer Systems.
FAQ
Questions about the Applied Analytics OMA BTX Analyzer
Answers from our engineering team on installation, compatibility and integration.
01How does the OMA BTX Analyzer compare to gas chromatography for BTX measurement?
The OMA BTX Analyzer delivers a continuous reading every 1-5 seconds using dispersive UV-Vis spectroscopy, versus the multi-minute cycle time and carrier-gas consumption of a comparable gas-chromatography analyzer, making it far better suited to real-time blend-gate and process control decisions.
02What installation footprint does the OMA BTX Analyzer require?
Because the standard configuration handles sample conditions up to 150 degrees C and 3000 psi directly, the OMA BTX Analyzer typically needs a much smaller sample-conditioning skid than extractive GC system, reducing both installation cost and downtime.
03What concentration range can the OMA BTX Analyzer measure?
The analyzer covers a wide dynamic range from approximately 0-10 ppm trace-level detection up to 0-100% concentration, allowing the same core platform to serve both fuel-specification compliance monitoring and higher-concentration process control applications.
04Can the OMA BTX Analyzer integrate with a blending control system?
Yes. Standard output is an isolated 4-20 mA analog signal per measured component, with optional Modbus, HART, and RS-485 protocols available for direct integration into a blend-control system, DCS, or laboratory information management system.
05Is Seven Star LLC an experienced supply partner for Applied Analytics products?
Yes. Seven Star LLC is an experienced supplier of Applied Analytics process analyzers in Oman and the GCC, supplying genuine equipment with calibration support and local technical support.