Tyco Fire Products BFV-300 Grooved End Butterfly Valve with Switches
Description
Overview
Tyco Fire Products BFV-300 is a grooved end butterfly valve of the indicating type, built for fire protection pipework where anyone walking past must be able to see whether the valve is open or closed. It is used as a system, sectional or pump control valve, and is offered from 2 inch to 12 inch (DN50 to DN300). A handwheel gear operator turns the disc, an indicator flag shows its position, and two sets of internal supervisory switches report any movement to the fire alarm panel.
The companion BFV-300C shares the same body but is the normally closed arrangement, with a black handwheel and switches wired for the closed position. This page describes the BFV-300, the red-handwheel valve for normally open service, using the values in the manufacturer datasheet.
Pressure ratings by size
A butterfly valve is smaller, lighter and quicker to fit than a gate valve of the same bore, and the grooved ends let a fitter join it with listed couplings instead of flanges and gaskets. The datasheet provides dimensional drawings with the face-to-face and handwheel clearances for each size, a nominal pressure drop against flow graph for sizing the hydraulic calculation, and an exploded parts list that names every gear operator component down to the bushings and spring pins, which helps when planning spares for a large site.
The pressure limit depends on size and approval body, so the table below keeps them together.
| Sizes | UL, ULC and FM maximum | VdS maximum |
|---|---|---|
| 2 to 8 inch (DN50 to DN200) | 300 psi (20,7 bar) | 300 psi (20,7 bar) |
| 10 inch (DN250) | 175 psi (12,1 bar) | 232 psi (16,0 bar) |
| 12 inch (DN300) | 175 psi (12,1 bar) | 175 psi (12,1 bar) |
The maximum working temperature is 212°F (100°C), measured in accordance with UL 1091. Listings and approvals include UL, ULC, FM, CE, VdS, CNPP (certificate 63.23.221) and the California State Fire Marshal, and the datasheet states that all of them cover indoor and outdoor use.
Tyco Fire Products BFV-300 construction and weights
| Component | Material or detail |
|---|---|
| Body | Ductile iron with black RILSAN PA11 coating |
| Disc | Ductile iron, EPDM encapsulated seal |
| Upper and lower stem | Stainless steel |
| Handwheel | Ductile iron, red painted for BFV-300 |
| Operator, 2 to 6 inch | IP65 bronze traveling nut gearbox in a ductile iron housing |
| Operator, 8 to 12 inch | IP65 brass segmented gearbox in a ductile iron housing |
| Seat leakage | Class VI (Type C) per ANSI/FCI 70-2-2006 (ASME B16.104) |
| Tapping bosses | 3/8 NPT for 2 to 3 inch, 1/2 NPT for 4 to 12 inch, factory plugged |
| Weights | 2 inch 10,8 lb (4,9 kg); 3 inch 13,9 lb (6,3 kg); 4 inch 17,64 lb (8,0 kg); 6 inch 30,42 lb (13,8 kg); 8 inch 47,18 lb (21,4 kg); 10 inch 73,41 lb (33,3 kg); 12 inch 89,29 lb (40,5 kg) |
Supervisory switches and wiring
Each gear operator holds two sets of single-pole double-throw switches installed at the factory. They change state during the first two revolutions of the handwheel away from the normal position, so a valve that is being shut is reported long before the flow is actually stopped. Switch S-1 is meant for the supervisory circuit of the fire alarm control panel under NFPA 72, and S-2 provides an auxiliary contact for equipment such as a bell or horn under NFPA 70. Contact ratings are 16 A at 125 or 250 V AC and 5 A at 24 V DC. In outdoor service, make the wiring connections above 15°F (-9°C) so the lead insulation stays flexible.
How Tyco Fire Products BFV-300 differs from related valves
Several look-alikes exist in the same family. The BFV-300C is the normally closed version of this valve. A wafer style BFV-300 has its own datasheet, and so does the BFV-250 wafer valve, while the older BFV-N grooved valve is listed as discontinued in the manufacturer library. The BFV-300 on this page is the grooved end version with internal supervisory switches, and its part number encodes the size: a 4 inch BFV-300 with switches is 59300G040WS, and a 4 inch BFV-300C is 59300G040WSC. Versions with a large 100 x 100 mm flag use the letters AWS (59300G040AWS), and versions with no internal switch, available only in EMEA, use NS (59300G040NS).
Part number key and accessories
The three digits after the letter G give the pipe size: 020 is 2 inch, 025 is 2-1/2 inch (73,0 mm pipe), 026 is DN65 (76,1 mm), 030 is 3 inch, 040 is 4 inch, 056 is DN125 (139,7 mm), 050 is 5 inch (141,3 mm), 066 is DN150 (165,1 mm), 060 is 6 inch, 080 is 8 inch, 100 is 10 inch and 120 is 12 inch. For valves without internal switches, external Bernstein i88-IP65 switches are 59300SPSW-1 (regular) and 59300SPSWLED (24 V LED), and the ATEX Ex IP66/67 switch is 59300SPSWATEX. Mounting brackets run from 59300SPBRACKET10 to 59300SPBRACKET30. Replacement handwheels for the red BFV-300 are 59300SPHWHEEL10 (2 to 4 inch), 59300SPHWHEEL20 (5 to 6 inch), 59300SPHWHEEL30 (8 inch) and 59300SPHWHEEL40 (10 to 12 inch), and replacement flags are 59300SPFLAG10, 59300SPFLAG20 and 59300SPFLAG30.
Where it is used in Oman and the GCC
Expect to see the BFV-300 at the base of risers in commercial towers, on sectional isolation points in hotels and malls, ahead of fire pump sets, and on industrial fire mains in refineries and plants. The ductile iron body with a polyamide coating copes with the humidity of coastal sites. For a foam system, the datasheet advises checking compatibility with the foam concentrate maker, because the concentrate may affect the valve materials.
Installation and adjustment
The valve may be installed with flow in either direction, horizontally or vertically, in any schedule or pressure class of pipe that is listed or approved for fire protection. Couplings must be listed or approved for fire service and fitted to the coupling manufacturer’s instructions. For 8 inch and larger valves with segmented gear operators, the open and closed disc positions can be adjusted with the left and right adjustment screws shown in the datasheet. Silicone-free versions are available on request.
Care and inspection
The indicator flag and the handwheel are the first things to check during a walk-round, because a valve left part closed after maintenance is the classic cause of an impaired system. Compare the flag position with the supervisory panel reading, confirm that the wiring gland and conduit are sealed, and exercise the valve on the schedule your inspection standard sets. Before closing the valve for maintenance, get permission from the proper authorities and notify everyone affected. Inspection, testing and maintenance follow NFPA 25 and local rules, and any impairment must be corrected immediately.
Related items you may also need: Ansul SAPPHIRE FK-5-1-12 Clean Agent Fire Suppression System | Minimax FSX Deluge Valve Set (DN 50 to DN 200) | Minimax MX 200 HFC-227ea Fire Extinguishing Systems | All Tyco Fire Products products.
Documents and quotation
The manufacturer datasheet, TFP1511 dated October 2025, is attached. Seven Star LLC is an independent supplier serving Oman and the GCC. To get a quotation for Tyco Fire Products BFV-300, send your RFQ with the size, whether you need BFV-300 or BFV-300C, switch arrangement, approval requirement and quantity.
Datasheets & Documents
- Datasheet Tyco Fire Products BFV-300 Grooved End Butterfly Valve Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Tyco Fire Products is the fire sprinkler and fire protection valve business whose roots go back to the Providence Steam and Gas Pipe Company, founded in Providence, Rhode Island in 1850. Frederick Grinnell took control of that company in 1869 and patented an improved, more sensitive sprinkler system in 1881, an early step toward the modern automatic sprinkler. Tyco Laboratories bought Grinnell Fire Protection Systems in 1976, and the business has been part of Johnson Controls since the merger with Tyco International in 2016. Its technical data sheets are issued from Cranston, Rhode Island.
Tyco Fire Products company profile
| Founded | 1850, Providence, Rhode Island, USA, as the Providence Steam and Gas Pipe Company (the Grinnell predecessor) |
|---|---|
| Headquarters | Cranston, Rhode Island, USA (address printed on the data sheets: 1467 Elmwood Avenue) |
| Ownership | A Johnson Controls business; Johnson Controls completed its merger with Tyco International in September 2016 |
| Core technology | Automatic sprinklers with glass bulb or fusible link elements, plus alarm, deluge, preaction, butterfly and check valves for water-based fire protection |
| Typical applications | Commercial buildings, high-piled storage warehouses, industrial plants and process hazards protected by wet pipe, deluge and preaction systems |
| Standards and approvals | UL and C-UL listings, FM approvals, VdS, LPCB and CE certifications on selected products, designed for NFPA 13 and NFPA 25 practice |
Milestones
- 1850: The Providence Steam and Gas Pipe Company is founded in Providence, Rhode Island.
- 1881: Frederick Grinnell patents an improved, more sensitive automatic sprinkler system.
- 1909: The General Fire Extinguisher company, part of the Grinnell history, opens its own foundry and shops in Cranston, Rhode Island.
- 1976: Tyco Laboratories purchases Grinnell Fire Protection Systems.
- 2016: Johnson Controls completes its merger with Tyco International, and Tyco Fire Products documentation carries the Johnson Controls name.
How a Tyco Fire Products automatic sprinkler works
An automatic sprinkler is a closed nozzle held shut by a heat sensitive element, so each sprinkler reacts on its own to the heat above a fire. In a glass bulb sprinkler such as the Series TY-B and TY-FRB, a small sealed bulb contains a coloured liquid that expands as the room warms; at the rated temperature the liquid shatters the bulb, the seal drops away and water flows onto the deflector, which breaks it into a spray. Standard response models use a 5 mm bulb and quick response models a 3 mm bulb, which heats faster. The Early Suppression, Fast Response storage sprinklers use a fusible link instead: two metal halves joined by a thin layer of solder that melts at 165°F or 212°F. Choose the temperature rating from the highest expected ceiling temperature, and the K-factor from the hydraulic design.
Where Tyco Fire Products are used in Oman and the GCC
These sprinklers and valves protect shopping malls, hotels, residential towers and hospitals, tall racked warehouses in industrial zones, and fuel, power and process plants where deluge systems are needed. Poly-Stainless sprinklers suit corrosive coastal air, while epoxy coated deluge valves are made for outdoor industrial installations.
Tyco Fire Products models we list
| Family | Examples |
|---|---|
| Poly-Stainless sprinklers (Series TY-B and TY-FRB) | TY3151 |
| ESFR storage sprinklers | TY7126, TY9226 |
| Alarm and riser check valves | AV-1-300, CV-1FR |
| Deluge valves | DV-5A |
| Butterfly valves | BFV-300 |
Ordering Tyco Fire Products: what we need
Seven Star LLC is an independent supplier serving Oman and the GCC. For sprinklers, send the sprinkler identification number, temperature rating, finish, thread and quantity. For valves, send the model, size, end connections, trim or accessory needs and the approval the project requires. For spares, quote the part number printed in the data sheet or on the nameplate, and we will confirm the full order code before quoting.
Facts checked against Tyco Fire Products technical data sheets published on the Johnson Controls documentation portal, and Wikipedia entries on Grinnell and Tyco International, November 2026.
Browse Tyco Fire Products by category: Fire Fighting.
FAQ
Questions about the Tyco Fire Products BFV-300 Grooved End Butterfly
Answers from our engineering team on installation, compatibility and integration.
01What sizes and pressure does Tyco Fire Products BFV-300 cover?
It covers 2 to 12 inch (DN50 to DN300), with UL, ULC and FM ratings of 300 psi (20,7 bar) up to 8 inch and 175 psi (12,1 bar) for 10 and 12 inch.
02What is the difference between BFV-300 and BFV-300C?
They share the body, but BFV-300 is the normally open valve with a red handwheel and open-position switches, and BFV-300C has a black handwheel and closed-position switches.
03What supervisory switches does the BFV-300 have?
Two factory installed sets of SPDT switches that transfer within the first two handwheel revolutions, rated 16 A at 125 or 250 V AC and 5 A at 24 V DC.
04What are the BFV-300 body and seal materials?
The body is ductile iron with a black RILSAN PA11 coating, the disc is ductile iron with an EPDM encapsulated seal, and the stems are stainless steel.
05Can the BFV-300 be installed in any direction?
Yes. It may be installed with flow in either direction, horizontally or vertically, using grooved couplings that are listed or approved for fire protection.