- Automation & ControlView all 2,085 products
- AC Drives
- Automation Accessories
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Motor Soft Starters
- Pneumatic Cylinders
- Industrial Computers
- Servo Drives
- Machine Vision
- Automation Software
- Robotics
Brand: Schneider Electric
Schneider Electric C10F1TM020 NSX100F 1P 20 A TM-D AC/DC Breaker
Description
C10F1TM020: 20 A single-pole ComPacT NSX100F AC/DC breaker
The C10F1TM020 is a Schneider Electric ComPacT NSX100F circuit breaker with one pole, a TM-D thermal-magnetic trip unit rated 20 A, designed for both AC and DC. The datasheet describes it as: ComPacT NSX100F AC/DC, 18 kA at 240 VAC, TMD trip unit 20 A, 1 pole 1d. Seven Star LLC supplies the C10F1TM020 in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: the NSX100 frame carries up to 100 A, the F letter is the breaking-capacity level (18 kA at 240 V AC for this one-pole version), and the datasheet’s trip unit name is TM-D with a fixed 20 A thermal setting and a fixed magnetic setting of 190 A.
Technical specifications of the C10F1TM020
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / C10F1TM020 |
| Device short name | NSX100F |
| Product type | Circuit breaker, distribution application |
| Poles / protected poles | 1P / 1D |
| Rated current In | 20 A at 40 °C |
| Network | AC 50/60 Hz and DC |
| Rated operational voltage Ue | 277 V AC 50/60 Hz; 250 V DC |
| Ui / Uimp | 750 V AC / 8 kV |
| Breaking capacity Icu | 18 kA at 220/240 V AC; 36 kA at 250 V DC |
| Service breaking capacity Ics | 18 kA at 220/240 V AC; 36 kA at 250 V DC |
| Breaking capacity code | F 18 kA 240 V AC |
| Trip unit | TM-D, thermal-magnetic, protection functions LI |
| Thermal pick-up Ir | Fixed, 1 x In = 20 A |
| Magnetic pick-up Ii | Fixed, 190 A |
| Isolation / category | Suitable for isolation (EN/IEC 60947-2); category A |
| Mechanical / electrical durability | 20000 cycles; 20000 cycles at 277 V In/2 and 10000 cycles at 277 V In |
| Power dissipation per pole | 4.01 W |
| Control / mounting | Toggle / fixed, backplate or flat on the back; front connections, 35 mm pitch |
| Dimensions W x H x D | 35 x 161 x 86 mm |
| Net weight | 0.7 kg |
| Degree of protection | IP40 (IEC 60529), IK07 (IEC 62262) |
| Overvoltage category / shock class | IV / Class II on front face |
| Ambient temperature, operation / storage | -25 to 70 °C / -50 to 85 °C |
| Standard | EN/IEC 60947-2 |
How the TM-D trip unit protects at 20 A
The TM-D unit is thermal-magnetic: a bimetal element for overload (L) and a magnetic element for short-circuit (I). Both are fixed on this reference. The long-time pick-up is fixed at 1 x In, which is 20 A, and the instantaneous pick-up is fixed at 190 A, about 9.5 times In (calculated).
Fixed settings keep the device simple and free from mis-adjustment, but they also mean the protection cannot be tuned for motor inrush or for selectivity. The datasheet lists no earth-leakage protection. If a load needs adjustable thresholds, a breaker with an adjustable or electronic trip unit is the route.
AC and DC ratings: where a single pole fits
The datasheet gives two sets of ratings. On AC, Ue is 277 V and Icu and Ics are 18 kA at 220/240 V; on DC, Ue is 250 V and Icu and Ics are 36 kA. A single-pole breaker has one contact gap, so it fits circuits where one conductor is switched: a phase-to-neutral circuit on a 400 V system, a single-phase supply, or a DC circuit up to 250 V where the polarity arrangement permits it.
For three-phase loads or for circuits that need all poles to open together, a multi-pole device is the correct choice; a multi-pole NSX100F version with its own datasheet ratings is the right basis.
| Supply | Ue | Icu / Ics |
|---|---|---|
| AC 50/60 Hz | 277 V | 18 kA at 220/240 V |
| DC | 250 V | 36 kA |
Size, heat and mounting
Power dissipation per pole is 4.01 W, a small number, but it adds up when many one-pole breakers are packed side by side in one distribution board. The device is 35 mm wide, 161 mm high and 86 mm deep and weighs 0.7 kg, so a row of these is compact.
Mounting is on a backplate or flat on the back, with front connections at 35 mm pitch. The front face is Class II; IP40 and IK07 apply, so installation is inside an enclosed panel. The overvoltage category is IV for this single-pole version.
Related references to the C10F1TM020
The same single-pole NSX100F family is available at other ratings. The closest neighbour in the range we handle is C10F1TM030, which differs in the thermal setting and the fixed magnetic pick-up (30 A and 300 A), while the frame, voltage and breaking capacity are the same. Other ratings exist in the family; ask us for current availability.
Choose between neighbouring ratings on the load current and conductor size, not on the breaker alone: the breaker rating must protect the cable.
Installing and maintaining the C10F1TM020
Mount the C10F1TM020 on the backplate or flat on the back as the installation instructions allow, connect the cable to the front terminals and torque it to the manufacturer’s value. Switch the toggle through its positions to confirm free operation, and record the nominal 20 A setting on the circuit schedule.
Maintenance is limited: periodic inspection of terminals for heat discolouration, a manual operation test and, after any trip, a check of the cause before reclosing. Mechanical durability is 20000 cycles; electrical durability is 20000 cycles at 277 V In/2 and 10000 cycles at 277 V In.
Applications in Oman and the GCC
In Oman and the GCC, a 20 A one-pole breaker is typical for lighting circuits, small fan and pump circuits, control power and instrumentation supplies in plants, camps and buildings. DC capability up to 250 V also makes it usable on battery and UPS circuits in substations and telecom rooms.
Selection and RFQ information for the C10F1TM020
- Load current and cable size, against the 20 A fixed rating.
- System: AC up to 277 V or DC up to 250 V, and the fault level.
- Pole count: single-pole here; two- or three-pole devices need different references.
- Accessories required.
- Quantity and delivery location in Oman or the GCC.
Send the part number C10F1TM020, the quantity and the delivery location, and if possible the circuit voltage and fault level.
Quote C10F1TM020 exactly on any purchase request.
The C10F1TM020 datasheet is the reference for the values above.
Documents and quotation
The official English datasheet for the C10F1TM020 is attached on this page. It lists the trip settings, ratings, dimensions and environmental data used above.
To request a quotation, send the part number C10F1TM020, the quantity and the delivery location. Seven Star LLC is an independent supplier in Muscat and quotes according to current availability.
Other Models in the Se Nsx100f 1p Range
Seven Star LLC supplies models from the Se Nsx100f 1p range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric C10F1TM020 NSX100F 1P 20 A TM-D AC/DC Breaker | Circuit Breakers | You are viewing this model |
| Schneider Electric C10F1TM030 NSX100F 1P 30 A TM-D AC/DC Breaker | Circuit Breakers | View details |
Datasheets & Documents
- Datasheet Schneider Electric C10F1TM020 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric C10F1TM020 NSX100F 1P 20 A TM-D
Answers from our engineering team on installation, compatibility and integration.
01What is the rated current of the C10F1TM020?
20 A at 40 °C with a fixed thermal setting of 1 x In.
02What is the magnetic trip level of the C10F1TM020?
The datasheet gives a fixed instantaneous pick-up of 190 A.
03Can the C10F1TM020 be used on DC?
Yes. The datasheet lists AC and DC networks, with Ue 250 V DC and a breaking capacity of 36 kA at 250 V DC.
04What is the breaking capacity of the C10F1TM020 on AC?
18 kA Icu and Ics at 220/240 V AC; Ue is 277 V AC.
05What are the dimensions of the C10F1TM020?
35 mm wide, 161 mm high and 86 mm deep, weight 0.7 kg.


















Reviews
There are no reviews yet.