Brand: Schneider Electric
Schneider Electric ATS01N232QN Altistart 01 Soft Starter 32 A
Description
ATS01N232QN: Altistart 01 soft starter, 32 A
The ATS01N232QN is a compact Schneider Electric Altistart 01 soft starter for asynchronous motors in simple machines. It is rated 32 A, uses a voltage-ramp start with an integrated bypass, and is only 45 mm wide, so it sits on a 35 mm DIN rail or on screws. This unit runs from a three-phase supply of 380–415 V and has its control supply built in, so no separate control voltage has to be wired. Seven Star LLC supplies the ATS01N232QN in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference against the datasheet: the compatibility code is ATS01N2, the digits 232 line up with the 32 A starter rating, and the ending QN goes with the 380–415 V supply and built-in control supply. That is our interpretation, not a published ordering key.
Technical specifications of the ATS01N232QN
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / ATS01N232QN |
| Range of product | Altistart 01 |
| Application | Simple machine; asynchronous motors |
| Starter rating (IcL) | 32 A |
| Utilisation category | AC-53B per EN/IEC 60947-4-2 |
| Supply voltage | 380–415 V (−10 / +10 %) |
| Supply voltage limits | 342–456 V |
| Supply frequency | 50–60 Hz ± 5 % |
| Motor power | 15 kW three-phase at 380–415 V |
| Current consumption | 160 A at nominal load |
| Power dissipation | 4.5 W at full load, 324.5 W in transient state |
| Type of start | Voltage ramp; starting torque 30–80 % of direct-on-line value |
| Starting time | Adjustable 1–10 s |
| Control circuit | Built into the starter |
| Bypass | Integrated |
| Dimensions (H x W x D) | 154 × 45 × 131 mm |
| Net weight | 0.56 kg |
| Degree of protection | IP20; pollution degree 2 |
| Operating temperature | −10 to 40 °C; 40 to 50 °C with 2 % derating per °C |
| Altitude | Up to 1000 m; above that 2.2 % derating per 100 m |
How the ATS01N232QN starts the motor
This starter raises the motor voltage along a ramp, which cuts the inrush and the starting torque shock compared with a direct-on-line start. The datasheet gives the starting torque as 30 to 80 % of the torque the motor would produce connected straight to the line, and the output voltage never exceeds the supply voltage. Once the ramp ends the integrated bypass takes the current, which is why the dissipation at full load is only 4.5 W while the transient state, at 324.5 W, is far higher. Current consumption at nominal load is listed as 160 A.
The starting time is adjustable from 1 to 10 s. A deceleration time of 1 to 10 s is also listed, so this version supports a soft stop for pumps and conveyors where abrupt stopping causes water hammer or product movement.
Selecting the ATS01N232QN for Oman and the GCC
- Motor full-load current compared with 32 A and motor power with the table above.
- Supply of 380–415 V (−10 / +10 %) at your site.
- Soft stop needed? Only the QN versions list a deceleration time.
- Enclosure space of 154 × 45 × 131 mm on a rail, and the 40 °C derating point in a warm switchroom.
Typical uses are small pumps, fans, compressors and conveyors on skids and utility cabinets in Gulf plants, where a gentle start protects belts, couplings and pipework. Fit it in a ventilated cabinet because summer ambient can approach the derating limit.
Mounting, wiring and environment for the ATS01N232QN
The unit measures 154 × 45 × 131 mm and weighs 0.56 kg. It mounts on a 35 mm rail or with screws using retractable fixings, vertically within ± 10 degrees. Power terminals take 1 to 10 mm² rigid (tightening torque 1.9 to 2.5 N.m) and control terminals 0.5 to 2.5 mm² (0.5 N.m). The degree of protection is IP20, so mount it in an enclosure.
The temperature range is −10 to 40 °C without derating and up to 50 °C at 2 % per degree. Above 1000 m the current derates 2.2 % per additional 100 m. Relative humidity is 5 to 95 % without condensation, and vibration, shock and EMC data (emissions class B per CISPR 11) are listed. Certifications named are C-Tick, CCC, UL, CSA and GOST, with CE marking.
Motor ratings of the ATS01N232QN
The datasheet lists these motor powers for this starter: 15 kW three-phase at 380–415 V. The power ranges quoted are 15–25 kW at 380–440 V three-phase. Because the supply is limited to 380–415 V three-phase, this version does not cover 230 V or single-phase motors. Always compare motor full-load current with the 32 A rating rather than relying on kW alone.
Control and signalling on the ATS01N232QN
Control is by three logic inputs (LI1, LI2 and BOOST) at 24 to 40 V, for stop, run and boost during start-up, with a relay output R1 (normally open) and an open-collector logic output LO1 that signals the end of starting. The relay is rated 2 A at 250 V AC or 30 V DC on an inductive load, and the minimum switching current is 10 mA at 6 V DC. Two LEDs (green for powered up, yellow for nominal voltage reached) give the status, and the power and control sides are galvanically isolated.
The datasheet shows two-wire and three-wire control, including with deceleration, so the same starter can be driven from a switch or from start-stop buttons.
ATS01N232QN compared with other Altistart 01 ratings
| Reference | Rating | Supply | Height | Weight |
|---|---|---|---|---|
| ATS01N112FT | 12 A | 110–480 V (−10 / +10 %) | 124 mm | 0.28 kg |
| ATS01N125FT | 25 A | 110–480 V (−10 / +10 %) | 124 mm | 0.35 kg |
| ATS01N209QN | 9 A | 380–415 V (−10 / +10 %) | 124 mm | 0.42 kg |
| ATS01N232QN | 32 A | 380–415 V (−10 / +10 %) | 154 mm | 0.56 kg |
The N1 versions share the multi-voltage supply and the three control voltages, while the QN versions are three-phase 380–415 V with built-in control supply and soft stop. The ATSU01N232LT from the same lane is a related 32 A unit built for a TeSys U combination.
Information to send with an RFQ for the ATS01N232QN
- Reference ATS01N232QN and quantity.
- Motor power, full-load current, voltage and phases.
- Need for soft stop and control voltage.
- Ambient temperature and altitude.
- Delivery location and deadline.
Documents and quotation
The manufacturer datasheet for the ATS01N232QN is attached on this page. It holds the full specification table, the dimension drawings and the mounting and wiring pages summarised above.
Send us the reference ATS01N232QN, the quantity and the delivery location and Seven Star LLC will reply to your request for quotation. We are an independent supplier based in Muscat.
Other Models in the Se Altistart 01 Range
Seven Star LLC supplies models from the Se Altistart 01 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric ATS01N112FT Altistart 01 Soft Starter 12 A | Motor Soft Starters | View details |
| Schneider Electric ATS01N125FT Altistart 01 Soft Starter 25 A | Motor Soft Starters | View details |
| Schneider Electric ATS01N209QN Altistart 01 Soft Starter 9 A | Motor Soft Starters | View details |
| Schneider Electric ATS01N232QN Altistart 01 Soft Starter 32 A | Motor Soft Starters | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric ATS01N232QN Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric ATS01N232QN Altistart 01 Soft
Answers from our engineering team on installation, compatibility and integration.
01What is the rating of the ATS01N232QN?
The starter rating is 32 A, utilisation category AC-53B, with a voltage-ramp start and integrated bypass.
02Which motors can the ATS01N232QN start?
The datasheet lists 15 kW three-phase at 380-415 V.
03What supply does the ATS01N232QN use?
380-415 V (-10 / +10 %) with limits of 342-456 V. The control supply is built into the starter.
04Does the ATS01N232QN have a soft stop?
Yes, a deceleration time of 1 to 10 s is listed.
05What are the size and weight of the ATS01N232QN?
154 × 45 × 131 mm and 0.56 kg, IP20.