Brand: Schneider Electric
Schneider Electric A9S66492 Acti9 iSW 4P 125 A Switch
Description
A9S66492: Acti9 iSW 4P, 125 A switch-disconnector
The A9S66492 is a Schneider Electric Acti9 iSW modular switch, listed by the manufacturer as: switch disconnector iSW – 4P – 125 A – 415 V. It is a manual on/off device for DIN rail panels. It switches and isolates a circuit by hand and carries no overload or short-circuit element, so it always works together with a miniature circuit breaker or fuse upstream. Seven Star LLC supplies the A9S66492 in Oman and the GCC as an independent supplier in Muscat.
The reference reads as follows: Acti9 is the modular device range, iSW is the switch-disconnector line, 4P gives the number of poles and the 125 A figure is the rated operational current at 415 V. The category is AC-22A. The four-pole 125 A switch is the largest iSW reference in this group and acts as a compact main isolator for a small distribution board or an incoming switch on a feeder that carries a neutral.
Technical specifications of the A9S66492
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / A9S66492 |
| Description | switch disconnector iSW – 4P – 125 A – 415 V |
| Range / device | Acti9 / iSW switch-disconnector |
| Poles | 4P |
| Utilisation category | AC-22A |
| Rated operational current [Ie] | 125 A at 415 V |
| Rated operational voltage [Ue] | 415 V AC |
| Rated insulation voltage [Ui] | 500 V AC |
| Rated impulse withstand [Uimp] | 6 kV |
| Short-circuit making capacity [Icm] | 5 kA switch-disconnector alone |
| Short-time withstand [Icw] | 1500 A |
| Control / signalling | Toggle, ON/OFF indication |
| Dimensions (H x W x D) | 85 mm x 72 mm x 73 mm |
| Width in 9 mm modules | 8 |
| Net weight | 348 g |
| Colour | White |
| Mechanical / electrical durability | 20000 cycles / 2500 cycles |
| Terminals | tunnel type terminals (top or bottom): up to 1 x 50 mm² rigid; up to 1 x 35 mm² flexible; up to 1 x 35 mm² flexible with ferrule |
| Stripping length / tightening torque | 14 mm / 3.5 N.m |
| Standard | BS EN 60947-3, EN 60947-3, NZS 60947-3, IEC 60947-3, AS 60947-3 |
| IP / pollution degree | IP20 / 3 |
| Ambient temperature | Operation -25 to 60 °C; storage -40 to 85 °C |
| Relative humidity | 95 % at 55 °C |
How to read the ratings of the A9S66492
Utilisation category AC-22A means the switch is built for resistive and mixed inductive loads including moderate overloads, so the 125 A rating at 415 V applies to circuits of that kind. The insulation voltage of 500 V AC and the impulse withstand of 6 kV describe how the switch behaves with respect to the supply and overvoltages, and they are different from the operating voltage.
A switch-disconnector has no tripping element. If the load is a motor, remember that the starting current is several times the running current, so the switch must be backed by a proper starter or a motor-rated device; the A9S66492 is a means of switching and isolating, not of protecting. Its datasheet lists 2,500 cycles of electrical durability, notably lower than the 10,000 cycles of the two-pole 100 A device, so a switch that will be operated under load every day should be sized with that number in mind.
Size, terminals and wiring of the A9S66492
The A9S66492 measures 85 mm high, 72 mm wide and 73 mm deep, which is 8 modules of 9 mm on the DIN rail and weighs 348 g. It is fixed-mounted on a DIN rail and finished in white. The toggle gives a clear ON/OFF indication, and the contact position is signalled.
Terminals are specified as tunnel type terminals (top or bottom): up to 1 x 50 mm² rigid; up to 1 x 35 mm² flexible; up to 1 x 35 mm² flexible with ferrule. The stripping length is 14 mm and the tightening torque 3.5 N.m, so use a torque screwdriver for repeatable connections. The datasheet notes comb busbar and distribution block compatibility at top or bottom, which speeds up multi-way boards.
Selection checklist for the A9S66492
Before ordering the A9S66492, confirm the following.
- Load current at the supply voltage: 125 A at 415 V.
- Number of poles: 4P, and whether the neutral must be switched.
- Upstream protection: the switch needs a breaker or fuse sized for the cable and the fault level.
- Space: 8 modules of 9 mm, 72 mm wide.
- Terminal cross-section and number of conductors per terminal: tunnel type terminals (top or bottom): up to 1 x 50 mm² rigid; up to 1 x 35 mm² flexible; up to 1 x 35 mm² flexible with ferrule.
- Ambient temperature: -25 to 60 °C in operation.
Acti9 iSW references compared with the A9S66492
It is 72 mm wide, eight 9 mm modules, which is double the two-pole 100 A reference A9S66291.
The table lists the iSW references covered on this site:
| Part number | Poles | Rating | Width | Weight |
|---|---|---|---|---|
| A9S60220 | 2P | 20 A | 18 mm | 66 g |
| A9S60232 | 2P | 32 A | 18 mm | 65 g |
| A9S60332 | 3P | 32 A | 36 mm | 117 g |
| A9S60420 | 4P | 20 A | 36 mm | – |
| A9S60432 | 4P | 32 A | 36 mm | 130 g |
| A9S61220 | 2P | 20 A | 18 mm | – |
| A9S66291 | 2P | 100 A | 36 mm | 179 g |
| A9S66492 | 4P | 125 A | 72 mm | 348 g |
Installation and maintenance of the A9S66492
Snap the A9S66492 onto the DIN rail, connect supply and load as shown by the markings on the device and the wiring diagram, and tighten to 3.5 N.m. Switch it on and off a few times without load to confirm the toggle movement and the position indication. Label the circuit clearly, because the whole purpose of the switch is to give a maintenance person a known point of isolation.
For high-current modular switches, check the tightness of every terminal with a calibrated tool before energising, and keep the comb busbar or cable arrangement free of mechanical stress. Thermal imaging during the first loaded week is a cheap way to catch a poor connection before it damages the switch or its neighbours. In service, look for heat marks near the terminals and re-check torque after the first weeks. The listed electrical durability of 2500 cycles refers to switching under load, so a switch that is operated frequently under load wears sooner than one that is only used for isolation.
Where the A9S66492 is used in Oman and the GCC
In Oman and the GCC, modular switch-disconnectors of this kind appear in building services boards, small industrial panels, utility rooms of water and desalination plants, camp accommodation, and equipment skids in the oil and gas sector. They give electricians a local isolation point without opening the whole panel.
Because the A9S66492 carries 125 A, cable lugs and busbar connections must be sized for the same current, otherwise the connection becomes the hot spot of the panel. Panel temperature is the practical concern in the region: compare the operating range of -25 to 60 °C with the temperature inside the enclosure on a summer afternoon, and add shading or ventilation if the margin is small. The A9S66492 should be treated as a switching and isolating device and combined with suitable protection.
Documents and quotation
A datasheet for this product is attached on this page. It carries the electrical, mechanical and environmental data summarised above, so check it against your own single-line diagram or panel drawing before ordering.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and operates separately from the manufacturer.
Other Models in the Se Acti9 Isw Range
Seven Star LLC supplies models from the Se Acti9 Isw range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric A9S60220 Acti9 iSW 2P 20 A Switch | Switchgear, Enclosures & Distribution | View details |
| Schneider Electric A9S60232 Acti9 iSW 2P 32 A Switch | Switchgear, Enclosures & Distribution | View details |
| Schneider Electric A9S60332 Acti9 iSW 3P 32 A Switch | Switchgear, Enclosures & Distribution | View details |
| Schneider Electric A9S60420 Acti9 iSW 4P 20 A Switch | Switchgear, Enclosures & Distribution | View details |
| Schneider Electric A9S60432 Acti9 iSW 4P 32 A Switch | Switchgear, Enclosures & Distribution | View details |
| Schneider Electric A9S61220 Acti9 iSW 2P 20 A Switch | Switchgear, Enclosures & Distribution | View details |
| Schneider Electric A9S66291 Acti9 iSW 2P 100 A Switch | Switchgear, Enclosures & Distribution | View details |
| Schneider Electric A9S66492 Acti9 iSW 4P 125 A Switch | Switchgear, Enclosures & Distribution | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric A9S66492 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric A9S66492 Acti9 iSW 4P 125 A
Answers from our engineering team on installation, compatibility and integration.
01What is the A9S66492?
The A9S66492 is a Schneider Electric Acti9 iSW 4P switch-disconnector rated 125 A at 415 V, in utilisation category AC-22A, mounted on a DIN rail.
02Does the A9S66492 protect against overload?
No. It is a manual switch without a trip element. The circuit must be protected by an upstream breaker or fuse selected for the cable and fault level.
03How wide is the A9S66492?
The datasheet lists 85 mm x 72 mm x 73 mm (H x W x D), which is 8 modules of 9 mm and a weight of 348 g.
04What terminals does the A9S66492 have?
The datasheet describes tunnel type terminals (top or bottom): up to 1 x 50 mm² rigid; up to 1 x 35 mm² flexible; up to 1 x 35 mm² flexible with ferrule, with a stripping length of 14 mm and a tightening torque of 3.5 N.m.
05What temperature range applies to the A9S66492?
Operation is listed at -25 to 60 °C and storage at -40 to 85 °C, with relative humidity of 95 % at 55 °C.


















Reviews