Samson TROVIS 3730-3 HART Smart Positioner
Description
Samson TROVIS 3730-3 is the HART smart positioner of the Series 3730, and the version most commonly found on process valves that need valve diagnostics. A 4 to 20 mA two-wire loop provides both the set point and the power, HART Revision 7 carries the configuration and status data, and an LCD with plain text shows NAMUR NE 107 messages directly at the valve. This page is based on the manufacturer’s data sheet T 8484-3, edition March 2025.
Core capabilities of TROVIS 3730-3
The positioner measures valve position with a non-contact sensor and a PID algorithm in the microcontroller. It supports single-acting and double-acting actuators, offers high air capacity, and has four initialisation modes plus a substitution mode that allows start-up while the plant is running without changing the valve position. A built-in temperature sensor and operating hours counter record the working conditions, and self-diagnostics are condensed into NE 107 status messages. EXPERTplus diagnostics (data sheet T 8389-3) add valve-level evaluation.
3730-3 technical data
| Set point | 4 to 20 mA, two-wire, minimum span 4 mA |
|---|---|
| Minimum current | 3.75 mA for display and HART operation; 3.90 mA for pneumatic function |
| Load impedance | up to 9.3 V, equal to 465 ohm at 20 mA |
| Static destruction limit | 40 V, internal current limit about 40 mA |
| Valve travel direct on Type 3277 | 3.6 to 30 mm |
| Travel NAMUR or VDI/VDE 3847 | 3.6 to 300 mm |
| Rotary angle | 24 to 100 degrees |
| Supply air | 1.4 to 7 bar (20 to 105 psi) |
| Hysteresis / sensitivity | up to 0.3 percent / up to 0.1 percent |
| Transit time | exhaust and supply each adjustable up to 240 s |
| Characteristics | linear, equal percentage, reverse equal percentage, Samson butterfly valve |
| Steady-state air use | about 65 normal litres per hour |
| Supply air capacity at 6 bar | 8.5 m3n/h, KVmax 0.09 |
| Exhaust capacity at 6 bar | 14.0 m3n/h, KVmax 0.15 |
| Ambient temperature | -20 to +85 C; -40 C with metal glands; -55 C low-temperature version |
| Communication | HART Revision 7 and SSP with TROVIS-VIEW |
| Protection | IP 66 / NEMA 4X |
| Weight | about 1.0 kg aluminium; about 2.2 kg stainless steel |
Optional modules for 3730-3
The positioner can be ordered with additional functions to match the valve duty. The sheet lists a position transmitter, inductive limit switches, software limit contacts with NAMUR or PLC binary outputs, forced venting, a binary input, a binary output (only in combination with limit switches) and pressure sensors. The pressure sensor option applies to hardware version 02.00.xx with firmware 2.02.xx and higher. Check this combination when you define the order.
How 3730-3 differs from other Series 3730 variants
Compared with the single-acting TROVIS 3730-1, which has a 330 ohm load and no HART, the 3730-3 allows 465 ohm, HART 7, double-acting actuators and EXPERTplus. Its minimum stroke is 3.6 mm against 3.5 mm. Compared with the fieldbus versions 3730-4 and 3730-5, it needs no bus power and uses a 4 to 20 mA loop. Compared with the 3730-0 it has digital control, a display and several characteristics, and hysteresis up to 0.3 percent instead of up to 1 percent.
Applications in Gulf plants
HART-capable loops are the norm in refineries, LNG and gas plants and power stations across the region, and most asset-management systems read HART variables such as valve travel and diagnostic status. A 3730-3 on a critical control valve provides partial stroke data, friction trends and temperature history without a separate diagnostic device. The same unit also works well on rotary valves with a VDI/VDE 3845 bracket. A stainless steel housing option is available for corrosive coastal or offshore atmospheres.
Installation notes
- Select an attachment: Samson direct, NAMUR rib, IEC 60534-6-1 yoke, VDI/VDE 3847 or a rotary bracket
- Check air quality: particle class 4, oil class 3, dew point at least 10 K below the lowest ambient temperature
- Connect the loop to screw terminals sized 0.2 to 2.5 mm2 through the M20x1.5 gland for 6 to 12 mm cable
- Initialise with the preferred mode; the display can be rotated to read correctly in any position
Reliability and environmental data
Housing and cover are die-cast aluminium EN AC-44300 with chromate and powder coating, the window is Makrolon 2807, and cable glands come in polyamide, nickel-plated brass or stainless steel 1.4305, which lets buyers match the gland to the cable and the area classification.
The sheet quotes vibration immunity of 0.75 mm from 10 to 60 Hz and 100 m/s2 from 60 to 500 Hz per axis, shock of 150 m/s2 for 6 ms with 4000 bumps per axis, and storage class 1K6 with up to 95 percent relative humidity. The temperature effect is up to 0.15 percent per 10 K and the supply air influence is stated as none. Ex approvals follow Tables 1 and 2 of the data sheet. Confirm the exact variant on the nameplate before installation.
Commissioning with HART tools
Because the 3730-3 carries HART Revision 7, a handheld communicator or an asset-management host can read the device tag, travel, set point, output pressure state and NE 107 status without opening the housing. Local configuration through the SSP interface works with TROVIS-VIEW. Before connecting a host, make sure the loop resistance seen by the modem still leaves enough compliance, since the positioner already consumes up to 9.3 V. Record the initialisation results (travel, transit times and friction) as a baseline; later EXPERTplus trends are far more useful when compared against a clean reference taken at commissioning.
Documents and quotation
The data sheet for TROVIS 3730-3 is on this page. In your RFQ, please give 3730-3, quantity, travel or angle, actuator type, Ex marking and options such as limit switches or forced venting. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Spares and Lifecycle Considerations
For critical service, many plants hold one Samson 3730-3 as an operational spare rather than waiting for a failure. When you plan spares, look at how many identical valve positioners units are installed, how long a replacement would take to arrive, and the cost of an unplanned stop. Store spare units in their original packaging in a dry, temperature-controlled area and record the part number and serial number in your maintenance system. We can quote single units or a small spares package and confirm the lead time for each item in writing.
Other Models in the Samson 3730 Range
Seven Star LLC supplies models from the Samson 3730 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Samson 3731-5 Ex d FOUNDATION Fieldbus Positioner | Valve Positioners | View details |
| Samson 3730-0 Analog Electropneumatic Positioner | Valve Positioners | View details |
| Samson TROVIS 3730-3 HART Smart Positioner | Valve Positioners | You are viewing this model |
Datasheets & Documents
- Datasheet Samson TROVIS 3730-3 HART Smart Positioner Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
SAMSON is a German manufacturer of control valves, actuators, positioners and self-operated regulators. Hermann Sandvoss founded the company in Düsseldorf on 1 April 1907, and its first important product was a thermostatic valve that controlled temperature without external power. After moves to Mannheim, SAMSON settled in Frankfurt am Main in 1916, where SAMSON AG is still headquartered.
Seven Star LLC supplies Samson control valves, pneumatic actuators and positioners to process plants in Oman, including the types listed on this page and their replacement units.
Samson company profile
| Founded | 1 April 1907, Düsseldorf, by Hermann Sandvoss, as VULCAN Technische Apparate Baugesellschaft; products sold under the SAMSON name |
|---|---|
| Headquarters | Frankfurt am Main, Germany, since 1916 |
| Legal form | SAMSON AG |
| First product | A self-operated thermostatic valve |
| Group brands | SAMSON together with PFEIFFER, LEUSCH, VETEC and AIR TORQUE |
| Product families | Globe valves such as Type 3241, rotary and butterfly valves, 3271 and 3277 pneumatic actuators, 3730 and 3731 positioners, self-operated pressure and temperature regulators |
Milestones
- 1907: Hermann Sandvoss founds the company in Düsseldorf.
- 1909: It is re-established as SAMSON Apparatebau GmbH.
- 1916: After a period in Mannheim, the company moves to Frankfurt am Main.
- 1975: The name becomes SAMSON Mess- und Regeltechnik.
Samson valve, actuator and positioner types
Samson builds a control valve from modules. The Type 3241 globe valve is the general-service body of Series 240, and the Type 3251 is the Series 250 body for higher pressure ratings. Either one is combined with a Type 3271 pneumatic diaphragm actuator or a Type 3277, whose yoke allows the positioner to be attached directly with a concealed travel linkage.
Among the positioners listed are the Type 3725 and the Type 3730 family: the 3730-1 as the basic electropneumatic version, sold in its current generation as TROVIS 3730-1, and the 3730-3 with HART communication and valve diagnostics. Samson also makes PROFIBUS PA and FOUNDATION fieldbus variants in the same family, plus self-operated pressure and temperature regulators.
Where Samson valves are used
Samson control valves throttle steam, gas and liquids in chemical and petrochemical units, refineries, gas processing, power stations, water and desalination plants, and food production. Many reach site as part of a skid or package, so the plant instrument team often meets them first when a positioner or actuator needs replacing. We supply these items to end users and contractors throughout the GCC.
Samson products we list
Ordering Samson parts: what we need
Every Samson device has a nameplate with the type, a configuration ID (Var-ID) and a serial number. A photo of that plate is the surest route to an exact match. Without it, please send:
- Valve: type, DN or NPS, pressure rating, body and trim material, Kvs or Cv, plug and seat style, packing and bonnet type
- Actuator: type, effective area in cm², bench range, fail action and travel
- Positioner: full type code including Ex protection, communication and options such as limit switches or position transmitter
We check the code against Samson documentation and provide the manufacturer's data sheet on request.
Facts checked against SAMSON's corporate chronicle and press material, October 2026.
Browse Samson products by category: Control Valves, Valve Positioner, Valve Actuator.
FAQ
Questions about the Samson TROVIS 3730-3 HART Smart Positioner
Answers from our engineering team on installation, compatibility and integration.
01What communication does Samson 3730-3 use?
It uses a 4 to 20 mA two-wire loop with HART Revision 7 and an SSP interface for local TROVIS-VIEW configuration.
02Can 3730-3 be used on double-acting actuators?
Yes. The data sheet describes it as suitable for single-acting or double-acting actuators, which the TROVIS 3730-1 is not.
03What load does TROVIS 3730-3 add to the loop?
The load impedance is up to 9.3 V, equal to 465 ohm at 20 mA.
04What diagnostics does 3730-3 include?
It has self-diagnostics as NE 107 messages, a temperature sensor, an operating hours counter and EXPERTplus valve diagnostics.
05Which options can be added to 3730-3?
Pressure sensors, position transmitter, inductive or software limit contacts, forced venting, binary input and binary output are listed.