- Automation & ControlView all 2,926 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Moore Industries
Moore Industries THZ3/PRG/4-20MA/12-42DC/-AIS [DIN] Transmitter
Description
Moore Industries THZ3/PRG/4-20MA/12-42DC/-AIS [DIN]: dual-input DIN module with built-in I.S. input
Moore Industries THZ3/PRG/4-20MA/12-42DC/-AIS [DIN] is the THZ3 for a cabinet or rail, ordered with the -AIS suffix. The suffix is what sets it apart: it integrates intrinsically safe barrier protection on the sensor input side, so an RTD or thermocouple located in a Class I Division 1 or Zone 0 or 1 hazardous area can be wired straight to the DIN module in the safe area. The blue terminals identify the I.S. input at a glance.
The rest is the THZ3 platform: dual sensor input, HART 7, Namur 43 fail response and 20-bit input resolution inside a slim DIN body.
In practice this means one component replaces two. A traditional installation of a hazardous-area thermocouple needs a Zener barrier or a galvanic isolator, a rail-mounted transmitter, and the wiring between them. The -AIS module keeps the signal chain short, which reduces terminal count and the places where a loose screw can create a fault. It also keeps loop calculation simpler, because the loop side of the module is an ordinary 2-wire circuit.
Features of THZ3/PRG/4-20MA/12-42DC/-AIS [DIN]
- Integrated I.S. input protection, replacing a separate temperature barrier or isolator.
- Two sensors on one module for failover, average, differential or low or high select.
- Sensor drift and corrosion detection, smart range alarms and an input simulation function.
- HART 7 and DTM support so that PACTware and other FDT frames can configure the module.
- Supply of 12-42 V DC on the loop with 500 Vrms isolation and a 1350 Vac test.
The -AIS version keeps the supply at 12-42DC, unlike field I.S. versions limited to 12-30DC, because the barrier is on the sensor side and the loop stays in the safe area.
THZ3/PRG/4-20MA/12-42DC/-AIS [DIN] specification table
Values apply to the THZ3 in the DIN housing.
| Parameter | Value for THZ3/PRG/4-20MA/12-42DC/-AIS [DIN] |
|---|---|
| Model code | THZ3/PRG/4-20MA/12-42DC/-AIS [DIN] |
| Housing | DIN: DIN-style aluminum housing for 35 mm Top Hat (EN 50022) rail |
| Option | -AIS: built-in intrinsic safety barrier protection for sensors in Class I Div 1 and Zone 0/1 locations; blue input terminals; DIN housing only |
| Input | PRG: single or dual input; 14 RTD types, 9 thermocouple types (J, K, E, T, R, S, B, N, C), 0 to 4000 ohm, -50 to 1000 mV, potentiometer |
| Output | 4-20 mA scalable; HART 7; addresses 0 to 63 |
| Supply | 12-42 V DC |
| Isolation | 500 Vrms input to output; 1350 Vac one-minute dielectric test |
| Cold junction error | Plus or minus 0.45 C (DIN) |
| Weight | 221 g (7.9 oz) |
| Output accuracy | 3 microamps (0.019% of the 4-20 mA span) |
| Step response | 460 ms single, 650 ms dual input (typical) |
| Damping | 0 to 60 seconds |
| RFI/EMI | 10 V/m at 80-1000 MHz for DIN; 20 V/m with the -RF option |
| Fail response | Namur 43; upscale 23.6 mA or downscale 3.6 mA; preset or hold-last |
| Ambient | -40 to +85 C |
| Display | None in the DIN housing |
How THZ3/PRG/4-20MA/12-42DC/-AIS [DIN] differs from other THZ3 variants
The LH2NS and BH2NGP variants sit at the sensor and are explosion-proof; this DIN module is mounted in a safe area and brings the I.S. circuit to the sensor. It weighs 221 g against 644 g for the LH2 head assembly. Its cold junction error of 0.45 C is wider than the 0.25 C of the HPP module.
Without the -AIS suffix the same DIN code would not have an I.S. input; and adding -RF instead gives 20 V/m immunity but not the barrier, since the datasheet lists them as separate options.
A quick way to read this table is to look for what is missing: there is no display entry, no enclosure weight beyond 221 g, and no explosion-proof marking for the module itself, because the module is designed to be placed in the safe area. The hazardous-area capability is carried by the blue input terminals and the -AIS circuitry behind them.
Applications
Use it where sensors sit in classified areas and the instrument room is safe: tank temperature points in a terminal, thermocouples on a cracker, bearing RTDs on compressors, and gas-line temperatures at a metering skid. The single module replaces a barrier and a transmitter, saving rail space and wiring.
In Oman petrochemical sites, it reduces spares because one DIN unit covers both functions.
Selection notes
Verify that the intrinsic safety documentation covers the sensor and cable parameters, since entity values still apply. Select -AIS only if sensors are in hazardous areas; otherwise the plain DIN code is enough.
Because the module has no display, plan commissioning with a HART communicator or a PC and a HART modem.
When you compare this to a competing arrangement of separate barrier plus transmitter, remember to compare the combined accuracy and the combined rail width, not only the price of each part. A single THZ3 -AIS module provides the HART 7 device intelligence of the dual input transmitter without adding the series resistance of a barrier into the sensor circuit.
Installing THZ3/PRG/4-20MA/12-42DC/-AIS [DIN]
Snap the module onto the Top Hat rail, wire the sensors to the blue terminals, and run intrinsically safe cabling separately from other wiring, keeping the blue terminals segregated. Connect the loop supply to the PS terminals and power up.
Select the sensor types, the dual-input mode and the failure values with the HART tool, and run a loop test at 4, 12 and 20 mA.
Maintenance
Inspect terminals and the blue I.S. markings at plant shutdowns, and keep records of the configuration. If a sensor drifts, the diagnostics will report it before the measurement degrades.
Replace the module with an identical code to preserve the I.S. protection.
Supply of THZ3/PRG/4-20MA/12-42DC/-AIS [DIN]
Quote THZ3/PRG/4-20MA/12-42DC/-AIS [DIN] exactly and state sensor types for configuration.
Seven Star LLC is an independent supplier serving Oman and the wider GCC and is not affiliated with the manufacturer; all names and part numbers are used only to identify the product being requested.
Documents and quotation
A datasheet for Moore Industries THZ3/PRG/4-20MA/12-42DC/-AIS [DIN] is available with our quotation. Send an RFQ with part number, quantity and delivery location.
Other Models in the THZ3 TDZ3 Range
Seven Star LLC supplies models from the THZ3 TDZ3 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Moore Industries THZ3/PRG/4-20MA/12-30DC [LH2NS] Transmitter | Temperature Transmitters | View details |
| Moore Industries THZ3/PRG/4-20MA/12-42DC/-AIS [DIN] Transmitter | Temperature Transmitters | You are viewing this model |
Datasheets & Documents
- Datasheet Moore Industries THZ3/PRG/4-20MA/12-42DC/-AIS [DIN] Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.
Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.
Moore Industries company profile
| Founded | 1968, North Hills, California, USA, by Leonard W. Moore |
|---|---|
| Headquarters | North Hills, California, since 1974 |
| Ownership | Privately owned (Moore Industries-International, Inc.) |
| First product | SCT signal converter |
| Product families | Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA) |
Milestones
- 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
- 1974: The company moves into its North Hills headquarters.
- 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.
Moore Industries product families on this page
The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:
- Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
- Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
- Signal isolators, repeaters and converters: the SIX
- PID controllers and backup stations: the 535 in 1/4 DIN format
Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.
Where Moore Industries instruments are used
These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.
Moore Industries products we list
Ordering Moore Industries instruments: what we need
Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.
Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.
Browse Moore Industries products by category: Temperature Instrumentation, Controllers & Data Acquisition, Isolator & Barrier.
FAQ
Questions about the Moore Industries THZ3/PRG/4-20MA/12-42DC/-AIS [DIN]
Answers from our engineering team on installation, compatibility and integration.
01What does -AIS add?
It builds intrinsic safety barrier protection into the input so sensors in Class I Div 1 and Zone 0/1 areas connect directly; terminals are blue.
02Is -AIS available in field housings?
No. The datasheet states the option is for the DIN housing only.
03Does this unit have a display?
No. The DIN housing has no local display, so readings are taken from the loop or through HART tools.
04What is the supply range?
The 12-42DC field in this code means 12 to 42 V DC at the loop terminals of the module.
05Can it use two sensors?
Yes. Dual input supports backup and failover, average, differential and low or high select.

















![Moore Industries THZ3/PRG/4-20MA/12-42DC/-AIS [DIN] Transmitter Moore Industries THZ3/PRG/4-20MA/12-42DC/-AIS [DIN] Transmitter](https://omansevenstar.com/wp-content/uploads/2026/11/moore-industries-thz3-prg-4-20ma-12-42dc-ais-din-dual-input-hart-transmitter-ais-din-rail.webp)
Reviews
There are no reviews yet.